Standard Test Method for Deflection of Resilient Floor Tile

SCOPE
1.1 This test method is used to determine the deflection of relatively rigid resilient floor tile such as vinyl composition tile.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Mar-2001
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM F1304-90(1994)e1 - Standard Test Method for Deflection of Resilient Floor Tile
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
e1
Designation: F 1304 – 90 (Reapproved 1994)
Standard Test Method for
Deflection of Resilient Floor Tile
This standard is issued under the fixed designation F 1304; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
e NOTE—Keywords were added in September 1994.
1. Scope accurately centered between the two outside bars. Position the
frame so that the test sample can be placed with the wearing
1.1 This test method is used to determine the deflection of
surface touching the center bar, and the back surface touching
relatively rigid resilient floor tile such as vinyl composition
the two outer bars, without deflection of the sample. This is the
tile.
zero point for measuring deflection. Check that the deflection
2. Referenced Documents
speed of the tester is 4 6 ⁄8 in./min. (102 6 3 mm/min.).
Check the deflection measuring device to see that it accurately
2.1 Government Standard:
measures the relative movement between the center bar and the
Federal Test Method Standard 501A, Method 3131
frame holding the two outer bars.
3. Significance and Use
NOTE 1—If a pendulum-type weighing system is used on the test
3.1 This test method measures a physical property associ-
machine, which has appreciable movement of the attached jaw, the
ated with resilient floor tile’s ability to conform to an uneven mechanism may be locked in place to make measurement of the deflection
easier, and to maintain the specified deflection rate, since measurement of
subfloor without breaking or cracking.
the load is not required. Electronic load cell machines usually have
negligible movement.
4. Apparatus
4.1 Deflection Frame, as shown in Fig. 1.
7. Conditioning
4.2 Tensile Test Apparatus, capable of holding the deflection
7.1 After cutting the samples to size, condition the samples
frame and having a movement of at least 2.5 in. (64 mm) at a
at 73.4 6 1.8°F (23 6 1°C) and 50 6 5 % relative humidity for
rate of 4 in. (100 mm)/min at a load of 10 lb.
3 h before testing.
4.3 Measuring Device, for measuring the deflection of the
specimen at break or pull out from between the support bars to
8. Procedure
a tolerance of 0.05 in. (1.3 mm).
8.1 Insert a specimen in the frame as described in 6.1 with
4.4 Cutting Device, for cutting the samples to 2 by 9 in. (50
the wearing surface against the center bar, and the back against
by 229 mm).
the two outer bars. Start the machine and record the deflection
at the point where the sample breaks, or pulls free from the
5. Sampling
outer bars. Record the deflection to the nearest 0.05 in. (1.3
5.1 Sampling shall be in accordance with Federal Test
...

Questions, Comments and Discussion