Standard Specification for Electrolytic Copper Cathode

ABSTRACT
This specification establishes the requirements for electrolytic copper cathode; electrorefined and electrowon. The cathode furnished shall conform to the chemical composition requirements specified. Cathodes shall withstand ordinary handling without breakage or excessive separation of nodules. They shall be substantially free of all foreign material; for example, copper sulfate, dirt, grease, and oil. Electrical resistivity of the cathodes shall be determined as the mean of results from four specimens.
SIGNIFICANCE AND USE
13.1 Calculated values shall be rounded to the desired number of places as directed in Practice E29.
SCOPE
1.1 This specification establishes the requirements for electrolytic copper cathode; electrorefined and electrowon.  
1.2 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
Note 1: Cathode produced to this specification corresponds to the designation “Cath” as defined in Classification B224 and may be used to produce all other coppers listed in Classification B224 that are normally produced from “Cath” copper.
Note 2: Grade 1 cathode conforms to the chemical compositional requirements of Copper UNS No. C11040, except for oxygen, and is suitable for the manufacture of wire rod as designated in Specification B49.  
1.3 The following hazard caveat applies to the test methods described in Annex A2 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.  
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
30-Jun-2021
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM B115-10(2021) - Standard Specification for Electrolytic Copper Cathode
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: B115 −10 (Reapproved 2021)
Standard Specification for
1
Electrolytic Copper Cathode
This standard is issued under the fixed designation B115; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* B846 Terminology for Copper and Copper Alloys
E29 Practice for Using Significant Digits in Test Data to
1.1 This specification establishes the requirements for elec-
Determine Conformance with Specifications
trolytic copper cathode; electrorefined and electrowon.
E50 Practices for Apparatus, Reagents, and Safety Consid-
1.2 Units—The values stated in inch-pound units are to be
erations for Chemical Analysis of Metals, Ores, and
regarded as standard. The values given in parentheses are
Related Materials
mathematical conversions to SI units that are provided for
E53 Test Method for Determination of Copper in Unalloyed
information only and are not considered standard.
Copper by Gravimetry
NOTE 1—Cathode produced to this specification corresponds to the
designation “Cath” as defined in Classification B224 and may be used to
3. Terminology
produce all other coppers listed in Classification B224 that are normally
produced from “Cath” copper. 3.1 For definition of general terms related to copper and
NOTE 2—Grade 1 cathode conforms to the chemical compositional
copper alloys, refer to the current editions of Classification
requirements of Copper UNS No. C11040, except for oxygen, and is
B224 and Terminology B846.
suitable for the manufacture of wire rod as designated in Specification
B49.
4. Ordering Information
1.3 The following hazard caveat applies to the test methods
4.1 Orders for product shall include the following
describedinAnnexA2ofthisspecification: This standard does
information, as applicable:
not purport to address all of the safety concerns, if any,
4.1.1 ASTM designation and year of issue (for example,
associated with its use. It is the responsibility of the user of this
B115 – XX),
standard to establish appropriate safety, health, and environ-
4.1.2 Cathode grade (Table 1),
mental practices and determine the applicability of regulatory
4.1.3 Size; full cathode or cut,
limitations prior to use.
4.1.4 Total weight of each size.
1.4 This international standard was developed in accor-
dance with internationally recognized principles on standard-
5. Chemical Composition
ization established in the Decision on Principles for the
5.1 Thecathodefurnishedshallconformtotherequirements
Development of International Standards, Guides and Recom-
of Table 1 for the grade specified in the contract or purchase
mendations issued by the World Trade Organization Technical
order.
Barriers to Trade (TBT) Committee.
5.2 These composition limits do not preclude the presence
2. Referenced Documents
of other elements. Limits may be established and analysis
2
2.1 ASTM Standards:
required for unnamed elements by agreement between the
B49 Specification for Copper Rod for Electrical Purposes
supplier and the purchaser and such agreement shall be part of
B193 Test Method for Resistivity of Electrical Conductor
the contract or purchase order.
Materials
6. Physical Property Requirements
B224 Classification of Coppers
6.1 Electrical Resistivity:
6.1.1 The maximum electrical resistivity for product pro-
1
ThisspecificationisunderthejurisdictionofASTMCommitteeB05onCopper
2
duced from Grade 2 cathode shall be 0.153 28 Ω·g/m (con-
and Copper Alloys and is the direct responsibility of Subcommittee B05.07 on
3
Refined Copper.
ductivity 100.0 % minimum IACS) at 20 °C (68 °F) annealed
Current edition approved July 1, 2021. Published July 2021. Originally approved
when tested in accordance with Test Method B193. Measure-
in 1938. Last previous edition approved in 2016 as B115 – 10 (2016). DOI:
ment error is not included in the maximum/minimum limit.
10.1520/B0115-10R21.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on NBS Notebook 100 available from National Technical Information Service
the ASTM website. (NTIS), 5301 Shawnee Rd, Alexandria, VA 22312, http://www.ntis.gov.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
B
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.