Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products

SCOPE
1.1 This specification covers the minimum requirements for the installation of interior nonstructural steel framing and furring members designed to receive screw-attached gypsum panel products. The steel framing and furring members covered in this specification are limited to those complying with Specification C645.
1.2 Details of construction for a specific assembly to achieve the required fire resistance shall be obtained from reports of fire-resistance tests, engineering evaluations, or listings from recognized fire testing laboratories.
1.3 The values stated in inch-pound units are to be regarded as the standard. The SI (metric) values given in parentheses are approximate and are provided for information purposes only.

General Information

Status
Historical
Publication Date
09-Nov-2000
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C754-00 - Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 754 – 00
Standard Specification for
Installation of Steel Framing Members to Receive Screw-
1
Attached Gypsum Panel Products
This standard is issued under the fixed designation C 754; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* 3. Terminology
1.1 This specification covers the minimum requirements for 3.1 Definitions—Terms shall be as defined in Terminology
the installation of interior nonstructural steel framing and C11.
furring members designed to receive screw-attached gypsum 3.2 Descriptions of Terms Specific to This Standard:
panel products. The steel framing and furring members cov- 3.2.1 channel, n—the material described in 4.3 to which
ered in this specification are limited to those complying with furring members are attached.
Specification C 645. 3.2.2 cross furring, n—furring member attached perpen-
1.2 Details of construction for a specific assembly to dicular to main runners or framing members.
achieve the required fire resistance shall be obtained from 3.2.3 cross furring member, n—a member installed perpen-
reports of fire-resistance tests, engineering evaluations, or dicularly to the main beams designed to receive screw attached
listings from recognized fire testing laboratories. gypsum panel products.
1.3 The values stated in inch-pound units are to be regarded 3.2.4 direct furring, n—furring members attached directly
as the standard. The SI (metric) values given in parentheses are to the structural members of the building.
approximate and are provided for information purposes only. 3.2.5 framing member, n—metal studs, runners (track), and
rigid furring channels designed to receive screw attached
2. Referenced Documents
gypsum panel products.
2.1 ASTM Standards:
3.2.6 furred ceiling, n—a ceiling in which the rigid furring
A 366/A 366M Specification for Commercial Steel (CS), channels and studs are attached directly to the structural
2
Sheet, Carbon, (0.15 Maximum Percent) Cold-Rolled members of the building.
A 641/A 641M Specification for Zinc-Coated (Galvanized)
3.2.7 furring, v—preparing a wall or ceiling with framing or
3
Carbon Steel Wire furring members to provide a level surface or airspace.
A 653/A 653M Specification for Steel Sheet, Zinc-Coated
3.2.8 furring member, n—metal studs, rigid furring chan-
(Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) nels, or channels used either as direct furring or as cross
3
by the Hot-Dip Process
furring.
C 11 Terminology Relating to Gypsum and Related Build- 3.2.9 grid suspension system, n—a ceiling system com-
4
ing Materials and Systems
posed of modular interlocking steel components designed to
C 645 Specification for Non-Load Bearing (Axial) Steel receive screw-attached gypsum panel products.
Studs, Runners, (Tracks), and Rigid Furring Channels for
3.2.10 main beam, n—the main support member of a grid
4
Screw Application of Gypsum Board suspension system that receives cross furring members.
3.2.11 main runner, n—the channel or stud that is attached
to or suspended from the structural members of the building.
1
This specification is under the jurisdiction of ASTM Committee C11 on
3.2.12 runner (track), n—a member designed to receive the
Gypsum and Related Building Materials and Systems and is the direct responsibility
ends of metal studs, attached directly to the structural members
of Subcommittee C11.03 on Specifications for Application of Gypsum and Other
Products in Assemblies. of the building.
Current edition approved Nov. 10, 2000. Published January 2001. Originally
3.2.13 suspended ceiling, n—a ceiling in which the main
published as C 754 – 74. Last previous edition C 754 – 99a.
runners and cross furring are suspended below the structural
2
Annual Book of ASTM Standards, Vol 01.03.
3
members of the building.
Annual Book of ASTM Standards, Vol 01.06.
4
Annual Book of ASTM Standards, Vol 04.01.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C754–00
4. Materials and Manufacture equivalent corrosion resistance, and shall have the following
minimum weights in lb per 1000 linear ft (kg/m):
4.1 Studs, Runners, Rigid Furring Channels, and Grid
Size, Weight Flange Width
Suspension Systems—see Specification C 645.
in. (mm) lb/1000 ft (kg/m) in. (mm)
4.2 Tie Wire and Hanger Wire—Zinc-coated (galvanized)
3 1
⁄4 (19) 277 (0.412) ⁄2 (13)
1 1
1 ⁄2 (38) 414
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.