ASTM D5685-95
(Specification)Standard Specification for "Fiberglass" (Glass-Fiber-Reinforced Thermosetting-Resin) Pressure Pipe Fittings
Standard Specification for "Fiberglass" (Glass-Fiber-Reinforced Thermosetting-Resin) Pressure Pipe Fittings
SCOPE
1.1 This specification covers "fiberglass" (glass-fiber-reinforced thermosetting-resin) fittings for use with filament wound or centrifugally cast fiberglass pipe, or both, in sizes 1 in. through 24 in. for pipe manufactured to Specification D 2996 or D 2997, or both.
1.2 The following safety hazard caveat pertains only to the test method portion, Section 7, of this specification:
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Note 1—The term "fiberglass pipe" as described in Section of this specification applies to both reinforced thermosetting resin pipe (RTRP) and reinforced polymer mortar pipe (RPMP).
Note 2—For the purposes of this standard, ploymer does not include natural polymers.
Note 3—There is no similar or equivalent ISO standard.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or
withdrawn. Contact ASTM International (www.astm.org) for the latest information.
Designation: D 5685 – 95
AMERICAN SOCIETY FOR TESTING AND MATERIALS
100 Barr Harbor Dr., West Conshohocken, PA 19428
Reprinted from the Annual Book of ASTM Standards. Copyright ASTM
Standard Specification for
“Fiberglass” (Glass-Fiber-Reinforced Thermosetting-Resin)
1
Pressure Pipe Fittings
This standard is issued under the fixed designation D 5685; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
3
1. Scope (Glass-Fiber-Reinforced-Thermosetting Resin) Pipe
D 3567 Practice for Determining Dimensions of Reinforced
1.1 This specification covers “fiberglass” (glass-fiber-
3
Thermosetting Resin Pipe (RTRP) and Fittings
reinforced thermosetting-resin) fittings for use with filament
D 4024 Specification for Reinforced Thermosetting Resin
wound or centrifugally cast fiberglass pipe, or both, in sizes 1
3
(RTR) Flanges
in. through 16 in. for pipe manufactured to Specification
3
F 412 Terminology Relating to Plastic Piping Systems
D 2996 or D 2997, or both.
F 477 Specification for Elastomeric Seals (Gaskets) for
1.2 The following safety hazard caveat pertains only to the
3
Joining Plastic Pipe
test method portion, Section 8, of this specification:
2.2 ANSI Standard:
1.3 This standard does not purport to address all of the
4
B16.5 Steel Pipe Flanges, Flanged Valves and Fittings
safety concerns, if any, associated with its use. It is the
2.3 API Standard:
responsibility of the user of this standard to establish appro-
5
15LR Low Pressure Fiberglass Line Pipe
priate safety and health practices and determine the applica-
bility of regulatory limitations prior to use.
3. Terminology
NOTE 1—The term “fiberglass pipe” as described in Section 3 of this
3.1 Definitions:
specification applies to both reinforced thermosetting resin pipe (RTRP)
3.1.1 General—Definitions are in accordance with Termi-
and reinforced plastic mortar pipe (RPMP).
nology D 883 or F 412. Abbreviations are in accordance with
NOTE 2—There is no similar or equivalent ISO standard.
Terminology D 1600, unless otherwise indicated. The abbre-
2. Referenced Documents viation for fiberglass pipe is RTRP and the abbreviation for
fiberglass fittings is RTRF.
2.1 ASTM Standards:
3.1.2 “fiberglass” pipe—tubular product containing glass
D 618 Practice for Conditioning Plastics and Electrical
2
fiber reinforcements embedded in or surrounded by cured
Insulating Materials for Testing
2
thermosetting resin. The composite structure may contain
D 883 Terminology Relating to Plastics
aggregate, granular or platelet fillers, thixotropic agents, pig-
D 1598 Test Method for Time-To-Failure of Plastic Pipe
3
ments, or dyes. Thermoplastic or thermosetting liners or
Under Constant Internal Pressure
coatings may be included.
D 1599 Test Method for Short-Time Hydraulic Failure Pres-
3
3.1.3 reinforced thermosetting resin pipe—fiberglass pipe
sure of Plastic Pipe, Tubing, and Fittings
without aggregate (RTRP).
D 1600 Terminology for Abbreviated Terms Relating to
2
3.1.4 reinforced plastic mortar pipe—fiberglass pipe with
Plastics
2 aggregate (RPMP).
D 1898 Practice for Sampling of Plastics
3.1.5 reinforced thermosetting resin fitting—fiberglass fit-
D 2143 Test Method for Cyclic Pressure Strength of Rein-
3 ting without aggregate (RTRF).
forced, Thermosetting Plastic Pipe
3.1.6 reinforced plastic mortar fitting—fiberglass fitting
D 2992 Practice for Obtaining Hydrostatic or Pressure De-
with aggregate (RPMF).
sign Basis for “Fiberglass” (Glass-Fiber-Reinforced
3
Thermosetting-Resin) Pipe and Fittings
4. Classification
D 2996 Specification for Filament Wound “Fiberglass”
3 4.1 This specification covers fiberglass fittings defined by
(Glass-Fiber-Reinforced-Thermosetting Resin) Pipe
type (method of manufacture), grade (general type of resin),
D 2997 Specification for Centrifugally Cast “Fiberglass”
class (configuration of joining system), and pressure rating.
4.2 Types:
1
This specification is under the jurisdiction of ASTM Committee D-20 on
Plastics and is the direct responsibility of Subcommittee D20.23 on Reinforced
4
Plastic Piping System and Chemical Equipment. Available from American National Standards Institute, 11 West 42nd St., 13th
Current edition approved April 15, 1995. Published June 1995. Floor, New York, NY 10036.
2 5
Annual Book of ASTM Standards, Vol 08.01. Available from American Petroleum Institute, 1220 L St., NW, Washington, DC
3
Annual Book of ASTM Standards, Vo1 08.04. 20005.
1
---------------------- Page: 1 ----------------------
D 5685
4.2.1 Type 1—Filament-wound fittings manufactured by tion. Flanges are in compliance with Specification D 4024.
winding continuous fibrous-glass strand
...
Questions, Comments and Discussion