ASTM A210/A210M-19
(Specification)Standard Specification for Seamless Medium-Carbon Steel Boiler and Superheater Tubes
Standard Specification for Seamless Medium-Carbon Steel Boiler and Superheater Tubes
ABSTRACT
This specification covers seamless medium-carbon steel boiler and superheater tubes. The specification also covers minimum-wall-thickness, tubing sizes, boiler flues including safe ends, arch and stay tubes. The specification provides tensile and hardness properties but only applicable to certain size limitations. Material manufacturing shall be killed. Tubes shall be made by seamless process, marked as either hot-finished or cold-finished. Surface condition shall be specifically stated in the order. Chemical composition shall conform to the requirements. Elemental composition other than listed here shall not be permitted. Tension test, flattening test, flaring test, hardness test, hydrostatic or nondestructive electric test shall be made on specimens. Superheater tubes shall be formed without defects and shall withstand expansion, beading, forging, welding, and bending.
SCOPE
1.1 This specification2 covers minimum-wall-thickness, seamless medium-carbon steel, boiler tubes and boiler flues, including safe ends (see Note 1), arch and stay tubes, and superheater tubes.
Note 1: This type is not suitable for safe ending by forge welding.
1.2 The tubing sizes and thicknesses usually furnished to this specification are 1/2 in. to 5 in. [12.7 to 127 mm] in outside diameter and 0.035 to 0.500 in. [0.9 to 12.7 mm], inclusive, in minimum wall thickness. Tubing having other dimensions may be furnished, provided such tubes comply with all other requirements of this specification.
1.3 Mechanical property requirements do not apply to tubing smaller than 1/8 in. [3.2 mm] in inside diameter or 0.015 in. [0.4 mm] in thickness.
1.4 This specification covers grades A-1 and C of Seamless Medium-Carbon Boiler and Superheater Tubes with different chemical and tensile requirements. (Table 1, Table 3, and Section 11.)
1.5 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system must be used independently of the other. Combining values from the two systems may result in nonconformance with the specification. The inch-pound units shall apply unless the “M” designation of this specification is specified in the order.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
General Information
Relations
Buy Standard
Standards Content (Sample)
This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation:A210/A210M −19
Standard Specification for
Seamless Medium-Carbon Steel Boiler and Superheater
1
Tubes
This standard is issued under the fixed designationA210/A210M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* 2. Referenced Documents
2 3
1.1 This specification covers minimum-wall-thickness, 2.1 ASTM Standards:
seamless medium-carbon steel, boiler tubes and boiler flues, A450/A450M Specification for General Requirements for
including safe ends (see Note 1), arch and stay tubes, and Carbon and Low Alloy Steel Tubes
superheater tubes.
3. Ordering Information
NOTE 1—This type is not suitable for safe ending by forge welding.
3.1 Orders for material under this specification should
1.2 The tubing sizes and thicknesses usually furnished to
include the following, as required, to describe the desired
1
this specification are ⁄2 in. to 5 in. [12.7 to 127 mm] in outside
material adequately:
diameter and 0.035 to 0.500 in. [0.9 to 12.7 mm], inclusive, in
3.1.1 Quantity (feet, metres, or number of lengths),
minimum wall thickness.Tubing having other dimensions may
3.1.2 Name of material (seamless tubes),
be furnished, provided such tubes comply with all other
3.1.3 Grade,
requirements of this specification.
3.1.4 Manufacture (hot-finished or cold-finished),
1.3 Mechanical property requirements do not apply to
3.1.5 Size (outside diameter and minimum wall thickness),
1
tubing smaller than ⁄8 in. [3.2 mm] in inside diameter or 0.015
3.1.6 Length (specific or random),
in. [0.4 mm] in thickness.
3.1.7 Optional requirements (Sections 7 and 10),
3.1.8 Test report required, (see Certification Section of
1.4 This specification covers gradesA-1 and C of Seamless
Specification A450/A450M),
Medium-Carbon Boiler and Superheater Tubes with different
3.1.9 Specification designation, and
chemical and tensile requirements. (Table 1, Table 3, and
3.1.10 Special requirements.
Section 11.)
1.5 The values stated in either inch-pound units or SI units
4. General Requirements
are to be regarded separately as standard. Within the text, the
4.1 Material furnished under this specification shall con-
SI units are shown in brackets. The values stated in each
form to the applicable requirements of the current edition of
system are not exact equivalents; therefore, each system must
Specification A450/A450M, unless otherwise provided herein.
be used independently of the other. Combining values from the
two systems may result in nonconformance with the specifi-
5. Manufacture
cation. The inch-pound units shall apply unless the “M”
designation of this specification is specified in the order. 5.1 Steelmaking Practice—The steel shall be killed.
1.6 This international standard was developed in accor- 5.2 The tubes shall be made by the seamless process and
dance with internationally recognized principles on standard-
shall be either hot-finished or cold-finished, as specified.
ization established in the Decision on Principles for the
Development of International Standards, Guides and Recom- 6. Heat Treatment
mendations issued by the World Trade Organization Technical
6.1 Hot-finished tubes need not be heat treated. Cold-
Barriers to Trade (TBT) Committee.
finished tubes shall be given a subcritical anneal, a full anneal,
or a normalizing heat treatment after the final cold finishing
1
This specification is under the jurisdiction of ASTM Committee A01 on Steel,
process.
Stainless Steel and Related Alloys and is the direct responsibility of Subcommittee
A01.09 on Carbon Steel Tubular Products.
Current edition approved May 1, 2019. Published May 2019. Originally
3
approved in 1938. Last previous edition approved in 2012 as A210/A210M – 02 For referenced ASTM standards, visit the ASTM website, www.astm.org, or
(2012). DOI: 10.1520/A0210_A0210M-19. contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
2
For ASME Boiler and Pressure Vessel Code applications see related Specifi- Standards volume information, refer to the standard’s Document Summary page on
cation SA-210 in Section II of that Code. the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
A210/A210M−19
TABLE 1 Chemical Requirements determined from the size of the tubes as prescribed in Table 2.
NOTE 3—For tensile and
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: A210/A210M − 02 (Reapproved 2012) A210/A210M − 19
Standard Specification for
Seamless Medium-Carbon Steel Boiler and Superheater
1
Tubes
This standard is issued under the fixed designation A210/A210M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope Scope*
2
1.1 This specification covers minimum-wall-thickness, seamless medium-carbon steel, boiler tubes and boiler flues, including
safe ends (see Note 1), arch and stay tubes, and superheater tubes.
NOTE 1—This type is not suitable for safe ending by forge welding.
1
1.2 The tubing sizes and thicknesses usually furnished to this specification are ⁄2 in. to 5 in. [12.7 to 127 mm] in outside
diameter and 0.035 to 0.500 in. [0.9 to 12.7 mm], inclusive, in minimum wall thickness. Tubing having other dimensions may be
furnished, provided such tubes comply with all other requirements of this specification.
1
1.3 Mechanical property requirements do not apply to tubing smaller than ⁄8 in. [3.2 mm] in inside diameter or 0.015 in. [0.4
mm] in thickness.
1.4 This specification covers grades A-1 and C of Seamless Medium-Carbon Boiler and Superheater Tubes with different
chemical and tensile requirements. (Table 1, Table 3, and Section 11.)
1.5 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text, the SI units
are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system must be used
independently of the other. Combining values from the two systems may result in nonconformance with the specification. The
inch-pound units shall apply unless the “M” designation of this specification is specified in the order.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization
established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued
by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
2. Referenced Documents
3
2.1 ASTM Standards:
A450/A450M Specification for General Requirements for Carbon and Low Alloy Steel Tubes
3. Ordering Information
3.1 Orders for material under this specification should include the following, as required, to describe the desired material
adequately:
3.1.1 Quantity (feet, metres, or number of lengths),
3.1.2 Name of material (seamless tubes),
3.1.3 Grade,
3.1.4 Manufacture (hot-finished or cold-finished),
3.1.5 Size (outside diameter and minimum wall thickness),
3.1.6 Length (specific or random),
3.1.7 Optional requirements (Sections 7 and 10),
3.1.8 Test report required, (see Certification Section of Specification A450/A450M),
1
This specification is under the jurisdiction of ASTM Committee A01 on Steel, Stainless Steel and Related Alloys and is the direct responsibility of Subcommittee A01.09
on Carbon Steel Tubular Products.
Current edition approved Sept. 1, 2012May 1, 2019. Published November 2012May 2019. Originally approved in 1938. Last previous edition approved in 20072012 as
A210/A210M – 02 (2012).(2007). DOI: 10.1520/A0210_A0210M-02R12.10.1520/A0210_A0210M-19.
2
For ASME Boiler and Pressure Vessel Code applications see related Specification SA-210 in Section II of that Code.
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
A210/A210M − 19
TABLE 3 Tensile Requirements
Grade A-1 Grade C
Tensile strength, min, ksi [MPa] 60 [415] 70 [485]
Yield strength, min, ksi [MPa] 37 [255] 40 [275]
Elongation in 2 in. or 50 mm, min, % 30 30
A A
For longitudinal strip tests, a deduction shall be 1.50 1.50
1
made for each ⁄32-in. [0.8-mm] decrease in
5
wall thickness under ⁄16 in. [8 mm] from the
basic minimum elongation of the following
percentage points
When standard round 2-in. or 50-mm gage length 22 20
or smaller proportionally sized specimen
with the gage length equal to 4D (four times
the d
...
Questions, Comments and Discussion