SIGNIFICANCE AND USE
This non-destructive test method contains procedures and equipment requirements to quantitatively determine the surface penetration of water at a single location on a masonry wall. It is not designed to determine the overall water penetration and leakage of a masonry system.
Excessive water penetration of masonry may degrade masonry wall performance with respect to thermal conductivity, durability, efflorescence, staining, corrosion of embedded metal items, and water leakage.
This test may be used to evaluate masonry walls in-situ or for field mock-up testing. Common applications of this method have been comparison of water penetration rates of walls before and after repairs, and testing the efficacy of coatings. Alternative procedures are also provided to simulate the effect of local climatology on water penetration of masonry wall surfaces.
The outer surface of all masonry walls will experience water penetration when subjected to wind-driven rain. The resistance to water penetration is dependent on materials, workmanship, design, and maintenance. Some wall types accommodate large volumes of water penetration, without deleterious effects, through the presence of properly designed and installed drainage systems including flashing and weep holes. Use of this standard without consideration of the overall wall system may lead to incorrect conclusions regarding performance.
It is the intent of this standard that a sheet of water be developed and maintained on the wall surface during testing. In some cases, due to the surface texture of the masonry, the application of a coating, or other factors, a sheet of water will not consistently form. In those cases, results of this test method will likely be inaccurate.
This test method is similar to but distinct from the laboratory Test Method E 514. This field test method is designed to test in-situ walls. E 514 laboratory test method is designed to test laboratory wall specimens. This test method determines water...
SCOPE
1.1 This test method covers the field determination of water penetration of a masonry wall surface under specific water flow rate and air pressure conditions. This test is intended for use on any masonry wall surface that can be properly instrumented and tested within the requirements of this standard.
1.2 This test method is not identical to and the results are not directly comparable with the laboratory standard Test Method E 514.
1.3 Surface penetration, as determined by this test method, is defined as the amount of water passing through the wall surface exposed to testing per unit time per unit area. This property is not directly comparable to overall water penetration and leakage, which are typically defined as the amount of water travelling completely through a masonry system.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard may involve hazardous materials, operations, or equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1601–08
Standard Test Method for
Field Determination of Water Penetration of Masonry Wall
1
Surfaces
This standard is issued under the fixed designation C 1601; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* 4. Significance and Use
4.1 This non-destructive test method contains procedures
1.1 This test method covers the field determination of water
penetrationofamasonrywallsurfaceunderspecificwaterflow and equipment requirements to quantitatively determine the
rate and air pressure conditions.This test is intended for use on surface penetration of water at a single location on a masonry
any masonry wall surface that can be properly instrumented wall. It is not designed to determine the overall water penetra-
and tested within the requirements of this standard. tion and leakage of a masonry system.
1.2 This test method is not identical to and the results are 4.2 Excessive water penetration of masonry may degrade
not directly comparable with the laboratory standard Test masonry wall performance with respect to thermal conductiv-
Method E 514. ity, durability, efflorescence, staining, corrosion of embedded
1.3 Surface penetration, as determined by this test method, metal items, and water leakage.
is defined as the amount of water passing through the wall 4.3 This test may be used to evaluate masonry walls in-situ
surface exposed to testing per unit time per unit area. This or for field mock-up testing. Common applications of this
property is not directly comparable to overall water penetration method have been comparison of water penetration rates of
andleakage,whicharetypicallydefinedastheamountofwater walls before and after repairs, and testing the efficacy of
travelling completely through a masonry system. coatings. Alternative procedures are also provided to simulate
1.4 The values stated in inch-pound units are to be regarded the effect of local climatology on water penetration of masonry
as standard. The values given in parentheses are mathematical wall surfaces.
conversions to SI units that are provided for information only 4.4 The outer surface of all masonry walls will experience
and are not considered standard. water penetration when subjected to wind-driven rain. The
1.5 This standard may involve hazardous materials, opera- resistance to water penetration is dependent on materials,
tions, or equipment. This standard does not purport to address workmanship, design, and maintenance. Some wall types
all of the safety problems associated with its use. It is the accommodate large volumes of water penetration, without
responsibility of the user of this standard to establish appro- deleterious effects, through the presence of properly designed
priate safety and health practices and determine the applica- and installed drainage systems including flashing and weep
bility of regulatory limitations prior to use. holes. Use of this standard without consideration of the overall
wall system may lead to incorrect conclusions regarding
2. Referenced Documents
performance.
2
2.1 ASTM Standards:
4.5 It is the intent of this standard that a sheet of water be
C 1232 Terminology of Masonry developedandmaintainedonthewallsurfaceduringtesting.In
E 514 Test Method for Water Penetration and Leakage
some cases, due to the surface texture of the masonry, the
Through Masonry application of a coating, or other factors, a sheet of water will
not consistently form. In those cases, results of this test method
3. Terminology
will likely be inaccurate.
3.1 For definitions of terms used in this test method, refer to
4.6 This test method is similar to but distinct from the
Terminology C 1232.
laboratory Test Method E 514. This field test method is
designed to test in-situ walls. E 514 laboratory test method is
1
designed to test laboratory wall specimens. This test method
This test method is under the jurisdiction of ASTM Committee C15 on
Manufactured Masonry Units and is the direct responsibility of Subcommittee
determines water penetration of the masonry at its surface.Test
C15.04 on Research.
Method E 514 measures the water that has penetrated into and
Current edition approved Nov. 1, 2008. Published November 2008. Originally
through the masonry specimen and is collected. Direct com-
approved in 2004. Last previous edition approved in 2006 as C 1601 – 06.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or parison of results from this test method and Test Method E 514
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
are inappropriate.
Standards volume information
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:C1601–06 Designation:C1601–08
Standard Test Method for
Field Determination of Water Penetration of Masonry Wall
1
Surfaces
This standard is issued under the fixed designation C 1601; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This test method covers the field determination of water penetration of a masonry wall surface under specific water flow
rate and air pressure conditions. This test is intended for use on any masonry wall surface that can be properly instrumented and
tested within the requirements of this standard.
1.2 This test method is not identical to and the results are not directly comparable with the laboratory standard Test Method
E 514“Test Method for Water Penetration and Leakage Through Masonry.”
1.3Surface penetration, as determined by this test method, is defined as the amount of water passing through the wall surface
exposed to testing per unit time per unit area. This property is not directly comparable to overall water penetration and leakage,
which are typically defined as the amount of water travelling completely through a masonry system.
1.4.
1.3 Surface penetration, as determined by this test method, is defined as the amount of water passing through the wall surface
exposed to testing per unit time per unit area. This property is not directly comparable to overall water penetration and leakage,
which are typically defined as the amount of water travelling completely through a masonry system.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard may involve hazardous materials, operations, or equipment. This standard does not purport to address all of
the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and
health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
C 1232 Terminology of Masonry
E 514 Test Method for Water Penetration and Leakage Through Masonry
3. Terminology
3.1 For definitions of terms used in this test method, refer to Terminology C 1232.
4. Significance and Use
4.1This4.1 This non-destructive test method contains procedures and equipment requirements to quantitatively determine the
surface penetration of water at a single location on a masonry wall. It is not designed to determine the overall water penetration
and leakage of a masonry system.
4.2 Excessive water penetration of masonry may degrade masonry wall performance with respect to thermal conductivity,
durability, efflorescence, staining, corrosion of embedded metal items, and water leakage.
4.3 This test may be used to evaluate masonry walls in-situ or for field mock-up testing. Common applications of this method
have been comparison of water penetration rates of walls before and after repairs, and testing the efficacy of coatings.Alternative
procedures are also provided to simulate the effect of local climatology on water penetration of masonry wall surfaces.
4.4 The outer surface of all masonry walls will experience water penetration when subjected to wind-driven rain.The resistance
to water penetration is dependent on materials, workmanship, design, and maintenance. Some wall types accommodate large
1
ThisTest Methodtest method is under the jurisdiction ofASTM Committee C15 on Manufactured Masonry Units and is the direct responsibility of Subcommittee C15.04
on Research.
Current edition approved JulyNov. 1, 2006.2008. Published July 2006.November 2008. Originally approved in 2004. Last previous edition approved in 20052006 as
C 1601 – 056.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book ofASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
C1601–08
volumesofwaterpenetration,withoutdeleteriouse
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.