Standard Guide for Design and Construction of Low-Rise Frame Building Wall Systems to Resist Water Intrusion

SIGNIFICANCE AND USE
This guide may be used by public agencies to set standards affecting the weather resistance, durability, and performance of new building wall systems, exterior deck and stair components, doors, windows, penetrations and sealant joints beyond those specifically defined in the building codes.
This guide may be used by building field inspectors as a resource for construction inspection during the construction phase of a project.
This guide may be used by private organizations or individuals to set standards affecting the weather resistance, durability, and performance of building walls.
This guide may be used by architects and engineers as a resource for making design decisions involving material selection, building wall detailing and specifications.
This guide may be used by architects and engineers as a resource for conducting submittal review and construction observation during the construction administration phase of a project.  
This guide may be used by contractors as a resource and checklist for exercising field quality control.
SCOPE
1.1 This guide describes design, specification, selection, installation, and inspection of new building wall systems, exterior deck and stair components, doors, windows, penetrations and sealant joints of wood and metal frame buildings, typically four stories or less, to minimize water intrusion.
1.2 This guide does not address prevention of damage caused by water originating from the use of wet building materials or from indoor or outdoor humidity. Water from these sources can be important, and the potential for damage caused by water from these sources must not be overlooked in building design or construction.  
1.3 This guide does not address roofing systems, except when the surface of a deck also serves as a roof and at locations where roof systems interface with building walls.
1.4 This guide does not address any type of barrier wall system.
1.5 This guide does not address any exterior insulation and finish system (EIFS).
1.6 This guide does not address foundation conditions where the bottom of a slab on grade or the grade of a crawl space is at or below the water table or subject to hydrostatic pressure.
1.7 This guide is intended to supplement and not duplicate building code requirements.
1.8 Maintenance, although important, is not covered in detail.  
1.9 Application of finishes, such as paint and sealers, may be important in the performance of some types of cladding; however, this is not covered in detail.
1.10 This guide applies only to constructions with sheathing, which facilitates installation of the weather-resistive barrier and associated flashings in a common plane.
1.11 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.12 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
1.13 Organization of Document:
Section Scope1 Referenced Documents2 Terminology3 Summary of Guide4 Significance and Use5 General Design Principles6 Design Practices7 General Guidelines8 Drainage Walls9  Drainage WallsGeneral9.1  Drainage Wall CladdingPortland Cement Plaster (Stucco)9.2  Drainage Wall CladdingWood and Wood-Derived Products9.3  Drainage Wall CladdingVinyl Siding9.4  Drainage Wall CladdingFiber-Cement Siding9.5 Cavity Drainage Walls10  Cavity Drainage WallsGeneral10.1  Cavity Drainage Wall CladdingMasonry10.2 Wood Framed Decks and Stairs with Exposed Framing
and Decking11 Plaza Decks or Stairs with Enclosed Framing and a
Waterproofing Membrane with Separat...

General Information

Status
Historical
Publication Date
31-Jan-2011
Current Stage
Ref Project

Relations

Buy Standard

Guide
ASTM E2266-11 - Standard Guide for Design and Construction of Low-Rise Frame Building Wall Systems to Resist Water Intrusion
English language
40 pages
sale 15% off
Preview
sale 15% off
Preview
Guide
REDLINE ASTM E2266-11 - Standard Guide for Design and Construction of Low-Rise Frame Building Wall Systems to Resist Water Intrusion
English language
40 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: E2266 − 11
Standard Guide for
Design and Construction of Low-Rise Frame Building Wall
1
Systems to Resist Water Intrusion
This standard is issued under the fixed designation E2266; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.10 This guide applies only to constructions with
sheathing, which facilitates installation of the weather-resistive
1.1 This guide describes design, specification, selection,
barrier and associated flashings in a common plane.
installation, and inspection of new building wall systems,
exterior deck and stair components, doors, windows, penetra-
1.11 The values stated in SI units are to be regarded as
tions and sealant joints of wood and metal frame buildings, standard. The values given in parentheses are mathematical
typically four stories or less, to minimize water intrusion.
conversions to inch-pound units that are provided for informa-
tion only and are not considered standard.
1.2 This guide does not address prevention of damage
caused by water originating from the use of wet building 1.12 This standard may involve hazardous materials,
materialsorfromindoororoutdoorhumidity.Waterfromthese operations, and equipment. This standard does not purport to
sources can be important, and the potential for damage caused address all of the safety concerns, if any, associated with its
bywaterfromthesesourcesmustnotbeoverlookedinbuilding use. It is the responsibility of the user of this standard to
design or construction. establish appropriate safety and health practices and deter-
mine the applicability of regulatory requirements prior to use.
1.3 This guide does not address roofing systems, except
1.13 Organization of Document:
whenthesurfaceofadeckalsoservesasaroofandatlocations
Section
where roof systems interface with building walls.
Scope 1
1.4 This guide does not address any type of barrier wall Referenced Documents 2
Terminology 3
system.
Summary of Guide 4
Significance and Use 5
1.5 This guide does not address any exterior insulation and
General Design Principles 6
finish system (EIFS).
Design Practices 7
General Guidelines 8
1.6 This guide does not address foundation conditions
Drainage Walls 9
where the bottom of a slab on grade or the grade of a crawl
Drainage Walls—General 9.1
space is at or below the water table or subject to hydrostatic Drainage Wall Cladding—Portland Cement Plaster 9.2
(Stucco)
pressure.
Drainage Wall Cladding—Wood and Wood-Derived 9.3
Products
1.7 This guide is intended to supplement and not duplicate
Drainage Wall Cladding—Vinyl Siding 9.4
building code requirements.
Drainage Wall Cladding—Fiber-Cement Siding 9.5
Cavity Drainage Walls 10
1.8 Maintenance, although important, is not covered in
Cavity Drainage Walls—General 10.1
detail.
Cavity Drainage Wall Cladding—Masonry 10.2
Wood Framed Decks and Stairs with Exposed Framing 11
1.9 Application of finishes, such as paint and sealers, may
and Decking
be important in the performance of some types of cladding;
Plaza Decks or Stairs with Enclosed Framing and a 12
Waterproofing Membrane with Separate Wearing
however, this is not covered in detail.
Surfaces
Plaza Decks or Stairs with Enclosed Framing and a 13
1
Waterproofing Membrane with an Integral Wearing
This guide is under the jurisdiction of ASTM Committee E06 on Performance
Surface
of Buildings and is the direct responsibility of Subcommittee E06.55 on Perfor-
Windows, Doors, and Similar Wall Penetrations 14
mance of Building Enclosures.
Special Wall Configuration 15
CurrenteditionapprovedFeb.1,2011.PublishedJune2011.Originallyapproved
Exterior Sealant Joints 16
in 2004. Last previous version approved in 2004 as E2266– 04.DOI: 10.1520/
Keywords 17
E2266-11.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
E2266 − 11
Applied Elastomeric Waterproofing Membrane with an
Section
Appendix—Additional Resources Appendix
Integral Wearing Surface
X1
C1180 Terminology of Mortar and Grout for Unit Masonry
Appendix—General Notes for Cement Plaster (Stucco) Appendix
Details X2 C1186 Specification for Flat Fiber-Cement Sheets
C1193 Guide for Use of Joint Sealants
2. Referenced Documents
C1209 Terminology of Concrete Masonry Units and Related
2 3
2.1 ASTM Standards: Units (Withdrawn 2009)
A153/A153M Specification for Zinc Coating (Hot-Dip) on C1232 Terminology of Masonry
Iron and Steel Hardware
C1299 Guide for Use in Selection of Liquid-Applied Seal-
3
C11 Terminology Relating to Gypsum and Related Building ants (Withdrawn 2012)
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:E2266–04 Designation:E2266–11
Standard Guide for
Design and Construction of Low-Rise Frame Building Wall
1
Systems to Resist Water Intrusion
This standard is issued under the fixed designation E2266; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 Thisguidedescribesdesign,specification,selection,installation,andinspectionofnewbuildingwallsystems,exteriordeck
and stair components, doors, windows, penetrations and sealant joints of wood and metal frame buildings, typically four stories
or less, to minimize water intrusion.
1.2 This guide does not address prevention of damage caused by water originating from the use of wet building materials or
from indoor or outdoor humidity. Water from these sources can be important, and the potential for damage caused by water from
these sources must not be overlooked in building design or construction.
1.3 This guide does not address roofing systems, except when the surface of a deck also serves as a roof and at locations where
roof systems interface with building walls.
1.4 This guide does not address any type of barrier wall system.
1.5 This guide does not address any exterior insulation and finish system (EIFS).
1.6 This guide does not address foundation conditions where the bottom of a slab on grade or the grade of a crawl space is at
or below the water table or subject to hydrostatic pressure.
1.7 This guide is intended to supplement and not duplicate building code requirements.
1.8 Maintenance, although important, is not covered in detail.
1.9 Application of finishes, such as paint and sealers, may be important in the performance of some types of cladding; however,
this is not covered in detail.
1.10This standard applies only to constructions with sheathing, which facilitates installation of the weather-resistive barrier and
associated flashings in a common plane.
1.11This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all
of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate
safety and health practices and determine the applicability of regulatory requirements prior to use.
1.10 This guide applies only to constructions with sheathing, which facilitates installation of the weather-resistive barrier and
associated flashings in a common plane.
1.11 The values stated in SI units are to be regarded as standard.The values given in parentheses are mathematical conversions
to inch-pound units that are provided for information only and are not considered standard.
1.12 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all
of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate
safety and health practices and determine the applicability of regulatory requirements prior to use.
1.13 Organization of Document:
Section
Scope 1
Referenced Documents 2
Terminology 3
Summary of Guide 4
Significance and Use 5
General Design Principles 6
Design Practices 7
General Guidelines 8
Drainage Walls 9
Drainage Walls—General 9.1
Drainage Wall Cladding—Portland Cement Plaster (Stucco) 9.2
1
This guide is under the jurisdiction ofASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.55 on Exterior Building
Wall Systems.
Current edition approved Dec. 1, 2004. Published January 2005. DOI: 10.1520/E2266-04.
Current edition approved Feb. 1, 2011. Published June 2011. Originally approved in 2004. Last previous version approved in 2004 as E2266– 04.DOI: 10.1520/E2266-11.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
E2266–11
Section
Drainage Wall Cladding—Wood and Wood-Derived Products 9.3
Drainage Wall Cladding—Vinyl Siding 9.4
Drainage Wall Cladding—Fiber-Cement Siding 9.5
Cavity Drainage Walls 10
Cavity Drainage Walls—General 10.1
Cavity Drainage Wall Cladding—Masonry 10.2
Wood Framed Decks and Stairs with Exposed Framing 11
and Decking
Plaza Decks or Stairs with Enclosed Framing and a 12
Waterproofing Membrane with Separate Wearing Surfaces
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.