Standard Test Method for Nonvolatile Content of Cold Liquid-Applied Elastomeric Waterproofing Membranes (Withdrawn 2015)

SIGNIFICANCE AND USE
This test method is used to determine the nonvolatile content of cold liquid-applied elastomeric waterproofing membranes and can be useful in determining application coverage rates.
SCOPE
1.1 This test method describes a laboratory procedure for determining the average nonvolatile content for one- or two-component cold liquid-applied elastomeric waterproofing membranes.
1.2 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.
1.3 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
WITHDRAWN RATIONALE
This test method described a laboratory procedure for determining the average nonvolatile content for one- or two-component cold liquid-applied elastomeric waterproofing membranes.
Formerly under the jurisdiction of Committee D08 on Roofing and Waterproofing, this test method was withdrawn in April 2015 in accordance with section 10.5.3.1 of the Regulations Governing ASTM Technical Committees, which requires that standards shall be updated by the end of the eighth year since the last approval date.

General Information

Status
Withdrawn
Publication Date
30-Jun-2005
Withdrawal Date
27-Apr-2015
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C1250-05 - Standard Test Method for Nonvolatile Content of Cold Liquid-Applied Elastomeric Waterproofing Membranes (Withdrawn 2015)
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C1250 −05
StandardTest Method for
Nonvolatile Content of Cold Liquid-Applied Elastomeric
1
Waterproofing Membranes
This standard is issued under the fixed designation C1250; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 5. Significance and Use
5.1 This test method is used to determine the nonvolatile
1.1 This test method describes a laboratory procedure for
content of cold liquid-applied elastomeric waterproofing mem-
determining the average nonvolatile content for one- or two-
branes and can be useful in determining application coverage
component cold liquid-applied elastomeric waterproofing
rates.
membranes.
6. Apparatus
1.2 The values stated in SI units are to be regarded as the
standard. The values in parentheses are for information only.
6.1 Forced-draft Oven, controlled to 70 6 2°C (158 6
3.6°F).
1.3 Thecommitteewithjurisdictionoverthisstandardisnot
6.2 Balance, sensitive to 0.01 g.
aware of any comparable standards published by other orga-
nizations.
6.3 Two Aluminum Weighing Dishes , 57 by 18 mm.
1.4 This standard does not purport to address all of the
7. Conditioning/Mixing
safety concerns, if any, associated with its use. It is the
7.1 Unless otherwise specified by those authorizing the
responsibility of the user of this standard to establish appro-
tests, standard conditions for all tests are 23 6 2°C (73.4 6
priate safety and health practices and determine the applica-
3.6°F) and 50 6 5 % relative humidity.
bility of regulatory limitations prior to use.
7.2 Store all membrane materials to be tested in an un-
opened container at standard conditions for at least 24 h before
2. Referenced Documents
any test specimens are prepared.
2
2.1 ASTM Standards:
7.3 Follow the manufacturer’s instructions for mixing and
C717 Terminology of Building Seals and Sealants
preparing membrane materials for testing. Thoroughly mix
one-component materials before using. Mix two-component
3. Terminology
compounds in the ratio recommended by the manufacturer.
3.1 Definitions—Refer to Terminology C717 for definitions
8. Procedure
used in standard.
8.1 For each test sample, prepare two test specimens as
4. Summary of Test Method
follows:
8.1.1 Mark each aluminum weighing dish for identification.
4.1 This test method consists of preparing duplicate
Accurately weigh each aluminum weighing dish to the nearest
samples, each of known mass, and aging these samples for 72
0.01 g. Record each mass.
hat70 6 2°C (158 6 3.6°F) in an air-circulating oven.
8.1.2 Place an aluminum weighing dish on the balance and
tare. Add 5.06 0.2 g of compound and spread evenly over the
interior surface area of the dish.
1
This test method is under the jurisdiction ofASTM Committee D08 on Ro
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.