Standard Specification for Copper Flat Products with Finished (Rolled or Drawn) Edges (Flat Wire and Strip)

ABSTRACT
This specification establishes the requirements for flat copper wire and strip products, with rolled or drawn finished edges produced for general applications. Unless otherwise established by agreement between the manufacturer and purchaser, products shall be produced in UNS Copper Nos. C10100, C10200, C10300, C10500, C10700, C10800, C11000, C11040, C12200, and C14200. The material for manufacture shall be a billet, cake, wire bar, or rod suitable for processing by hot working, cold working, and annealing to produce a uniform wrought structure in the finished product. Products shall be produced in the annealed (O61) and cold worked (H00, H01, H02, H03, H04, H06, and H08) tempers. Products shall be tested and shall adhere to dimensional (thickness, width, length, straightness, and edge contour), mechanical (tensile strength, elongation, Rockwell hardness, bend angle, and hydrogen embrittlement susceptibility), electrical resisitvity, and chemical composition requirements.
SCOPE
1.1 This specification establishes the requirements for copper products, flat wire and strip, with rolled or drawn finished edges produced for general application.
1.1.1 The product is produced in UNS Copper Nos. C10100, C10200, C10300, C10500, C10700, C10800, C11000, C11040, C12200, and C14200 unless otherwise established by agreement between manufacturer and purchaser.
1.2 Units Values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units, which are provided for information only and are not considered standard.Note 1
When a copper other than that listed in is designated by the purchaser, the resulting product shall conform to the physical, mechanical, performance, dimensional, and tolerance requirements per agreement between the manufacturer and purchaser.

General Information

Status
Historical
Publication Date
14-May-2007
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM B272-07 - Standard Specification for Copper Flat Products with Finished (Rolled or Drawn) Edges (Flat Wire and Strip)
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:B272 −07
StandardSpecification for
Copper Flat Products with Finished (Rolled or Drawn)
1
Edges (Flat Wire and Strip)
This standard is issued under the fixed designation B272; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* B577 Test Methods for Detection of Cuprous Oxide (Hydro-
gen Embrittlement Susceptibility) in Copper
1.1 This specification establishes the requirements for cop-
B846 Terminology for Copper and Copper Alloys
per products, flat wire and strip, with rolled or drawn finished
E8 Test Methods for Tension Testing of Metallic Materials
edges produced for general application.
E18 Test Methods for Rockwell Hardness of Metallic Ma-
1.1.1 The product is produced in UNS Copper Nos.
terials
C10100,C10200,C10300,C10500,C10700,C10800,C11000,
E53 Test Method for Determination of Copper in Unalloyed
C11040, C12200, and C14200 unless otherwise established by
Copper by Gravimetry
agreement between manufacturer and purchaser.
E62 Test Methods for Chemical Analysis of Copper and
1.2 Units—Values stated in inch-pound units are to be
Copper Alloys (Photometric Methods)
regarded as standard. The values given in parentheses are
E290 Test Methods for Bend Testing of Material for Ductil-
mathematical conversions to SI units, which are provided for
ity
information only and are not considered standard.
E478 Test Methods for ChemicalAnalysis of CopperAlloys
NOTE 1—When a copper other than that listed in 1.1.1 is designated by
the purchaser, the resulting product shall conform to the physical,
3. General Requirements
mechanical, performance, dimensional, and tolerance requirements per
agreement between the manufacturer and purchaser.
3.1 The following sections of Specification B248 constitute
a part of this specification for strip products and of Specifica-
2. Referenced Documents
tion B250/B250M for flat wire products:
2
2.1 ASTM Standards:
3.1.1 Terminology,
B5 Specification for High Conductivity Tough-Pitch Copper
3.1.2 Materials and Manufacture,
Refinery Shapes
3.1.3 Workmanship, Finish, and Appearance,
B170 Specification for Oxygen-Free Electrolytic Copper—
3.1.4 Sampling,
Refinery Shapes
3.1.5 Number of Tests and Retests,
B193 Test Method for Resistivity of Electrical Conductor
3.1.6 Specimen Preparation,
Materials
3.1.7 Test Methods,
B248 Specification for General Requirements for Wrought
3.1.8 Significance of Numerical Limits,
Copper and Copper-Alloy Plate, Sheet, Strip, and Rolled
3.1.9 Inspection,
Bar
3.1.10 Rejection and Rehearing,
B250/B250M Specification for General Requirements for
3.1.11 Certification,
Wrought Copper Alloy Wire
3.1.12 Test Reports,
B379 Specification for Phosphorized Coppers—Refinery
3.1.13 Packaging and Package Marking, and
Shapes
3.1.14 Supplementary Requirements.
3.2 In addition, when a section with a title identical to that
1
ThisspecificationisunderthejurisdictionofASTMCommitteeB05onCopper
referenced in 3.1 appears in this specification, it contains
and CopperAlloys and is the direct responsibility of Subcommittee B05.02 on Rod,
Bar, Wire, Shapes and Forgings.
additional requirements that supplement those appearing in
Current edition approved May 15, 2007. Published May 2007. Originally
Specifications B248 or B250/B250M, or both.
approved in 1952. Last previous edition approved in 2002 as B272 – 02. DOI:
10.1520/B0272-07.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or 4. Terminology
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
4.1 For definitions of terms related to copper and copper
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. alloys, refer to Terminology B846.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
B272−07
5. Ordering Information 7. Chemical Composition
5.1 When placing orders for product to this specification, 7.1 The material shall conform to the chemical composi-
include the following information: tional requirements in Table 1 for the copper UNS No.
5.1.1 ASTM designation and year of issue, designation specified in the ordering information.
5.1.2 Copper UNS No. designation (Section 1), 7.1.1 These compositional limits do not preclude the pres-
5.1.3 Temper—O61 (annealed), H00 (eight hard), H01 ence of other elements. When required, limits shall be estab-
(quarter hard), H02 (half ha
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.