Standard Test Method for Ethyl Methyl Pentanol Content and Purity Value of 2-Ethylhexanol By Gas Chromatography (Withdrawn 2021)

SIGNIFICANCE AND USE
4.1 This test method is used to determine the purity value and ethyl methyl pentanol content of 2-ethylhexanol.
SCOPE
1.1 This test method covers the determination of ethyl methyl pentanol content and purity value of 2-ethylhexanol.  
1.2 Water and acid cannot be determined by this test method and must be determined in accordance with Test Methods D1613 and E203 and those results used to normalize the chromatographic data.  
1.3 For purposes of determining conformance of an observed or a calculated value using this test method to relevant specifications, test result(s) shall be rounded off “to the nearest unit” in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.  
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.  
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see 6.1.1.  
1.6 For hazard information and guidance, see the supplier's Material Safety Data Sheet.

General Information

Status
Historical
Publication Date
30-Jun-2012
Current Stage
Ref Project

Buy Standard

Standard
ASTM D5008-07(2012) - Standard Test Method for Ethyl Methyl Pentanol Content and Purity Value of 2-Ethylhexanol By Gas Chromatography (Withdrawn 2021)
English language
4 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: D5008 − 07 (Reapproved 2012)
Standard Test Method for
Ethyl Methyl Pentanol Content and Purity Value of
1
2-Ethylhexanol By Gas Chromatography
This standard is issued under the fixed designation D5008; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* Determine Conformance with Specifications
E203 Test Method for Water Using Volumetric Karl Fischer
1.1 This test method covers the determination of ethyl
Titration
methyl pentanol content and purity value of 2-ethylhexanol.
1.2 Waterandacidcannotbedeterminedbythistestmethod
3. Summary of Test Method
and must be determined in accordance with Test Methods
3.1 Arepresentative specimen is introduced onto a capillary
D1613 and E203 and those results used to normalize the
column.The 2-ethylhexanol is separated from the ethyl methyl
chromatographic data.
pentanol and other impurities while the components are trans-
1.3 For purposes of determining conformance of an ob-
ported through the column by an inert carrier gas. The
served or a calculated value using this test method to relevant
separated components are measured in the effluent by a flame
specifications, test result(s) shall be rounded off “to the nearest
ionization detector and the areas for the peaks are determined
unit” in the last right-hand digit used in expressing the
by a suitable integration technique. The data are interpreted by
specification limit, in accordance with the rounding-off method
applying component detector response factors to the peak
of Practice E29.
areas, and the relative concentrations are determined by relat-
ing the individual peak responses to the total peak response.
1.4 The values stated in SI units are to be regarded as
Acidity and water are measured by Test Methods D1613 and
standard. No other units of measurement are included in this
E203, respectively, and the results are used to normalize the
standard.
values obtained by gas chromatography. An internal standard
1.5 This standard does not purport to address all of the
procedure is also included as an alternative calculation tech-
safety concerns, if any, associated with its use. It is the
nique. With this procedure, all impurities are determined
responsibility of the user of this standard to establish appro-
relative to the internal standard and the purity value is
priate safety and health practices and determine the applica-
determinedbysubtractingthesumoftheimpurities,water,and
bility of regulatory limitations prior to use. For a specific
acid from 100.
hazard statement, see 6.1.1.
1.6 For hazard information and guidance, see the supplier’s
4. Significance and Use
Material Safety Data Sheet.
4.1 This test method is used to determine the purity value
and ethyl methyl pentanol content of 2-ethylhexanol.
2. Referenced Documents
2
2.1 ASTM Standards:
5. Apparatus
D1613 Test Method for Acidity in Volatile Solvents and
5.1 Chromatograph—Any gas chromatograph designed or
Chemical Intermediates Used in Paint, Varnish, Lacquer,
modifiedforusewithcapillaryorwide-borecapillarycolumns.
and Related Products
The gas chromatograph should be equipped with a flame
E29 Practice for Using Significant Digits in Test Data to
ionization detector or other detector capable of operating with
these columns and capable of detecting impurities at a level of
0.01 weight % with a signal to noise ratio of at least 5:1.
1
This test method is under the jurisdiction of ASTM Committee D01 on Paint
and Related Coatings, Materials, andApplications and is the direct responsibility of
5.2 Column—Any column capable of resolving
Subcommittee D01.35 on Solvents, Plasticizers, and Chemical Intermediates.
2-ethylhexanol from ethyl methyl pentanol and other impuri-
Current edition approved July 1, 2012. Published September 2012. Originally
ties that may be present. The peaks should be resolved
approved in 1989. Last previous edition approved in 2007 as D5008 – 07. DOI:
10.1520/D5008-07R12.
quantitatively within a practical elapsed time. Columns that
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
meet the requirement of this test method are listed in Table 1.
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Other columns may be used, provided the user establishes that
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. a column gives the required separations.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

----------
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.