Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings

SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions and tolerances, pipe stiffness, crush resistance, impact resistance, hydrostatic burst resistance, and solvent cement for poly(vinyl chloride) plastic drain, waste, and vent pipe and fittings. A form of marking is also included. Plastic which does not meet the material requirements specified in Section 5 is excluded. Installation procedures are given in the Appendix.  
1.2 The values stated in inch-pound units are to be regarded as the standard. The metric equivalents of inch-pound units given in parentheses may be approximate.  
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.4 The following safety hazards caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-Sep-2002
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM D2665-02ae1 - Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings
English language
7 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Please contact ASTM International (www.astm.org) for the latest information.
An American National Standard
ϵ1
Designation: D 2665 – 02a
Standard Specification for
Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent
1
Pipe and Fittings
This standard is issued under the fixed designation D 2665; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (ϵ) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1
ϵ NOTE—Table 1, Tolerance on Avg. Column, was editorially corrected in April 2002.
1. Scope D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
Compounds and Chlorinated Poly(Vinyl Chloride)
1.1 This specification covers requirements and test methods
2
(CPVC) Compounds
for materials, dimensions and tolerances, pipe stiffness, crush
D2122 Test Method for Determining Dimensions of Ther-
resistance, impact resistance, hydrostatic burst resistance, and
3
moplastic Pipe and Fittings
solvent cement for poly(vinyl chloride) plastic drain, waste,
D2412 TestMethodforDeterminationofExternalLoading
and vent pipe and fittings.Aform of marking is also included.
3
Characteristics of Plastic Pipe by Parallel-Plate Loading
Plasticwhichdoesnotmeetthematerialrequirementsspecified
D2444 Test Method for Determination of the Impact Re-
in Section 5 is excluded. Installation procedures are given in
sistance of Thermoplastic Pipe and Fittings by Means of a
the Appendix.
3
Tup (Falling Weight)
1.2 The values stated in inch-pound units are to be regarded
D2564 Specification for Solvent Cements for Poly(Vinyl
as the standard. The metric equivalents of inch-pound units
3
Chloride) (PVC) Plastic Piping Systems
given in parentheses may be approximate.
D3311 Specification for Drain, Waste, and Vent (DWV)
1.3 Thetextofthisspecificationreferencesnotes,footnotes,
3
Plastic Fittings Patterns
and appendixes which provide explanatory material. These
D4396 Specification for Rigid Poly(Vinyl Chloride) (PVC)
notesandfootnotes(excludingthoseintablesandfigures)shall
and Chlorinated Poly(Vinyl Chloride) (CPVC) Com-
not be considered as requirements of the specification.
pounds for Plastic Pipe and Fittings Used in Nonpressure
1.4 The following safety hazards caveat pertains only to the
3
Applications
test methods portion, Section 7, of this specification: This
F402 Practice for Safe Handling of Solvent Cements,
standard does not purport to address all of the safety concerns,
Primers,andCleanersUsedforJoiningThermoplasticPipe
if any, associated with its use. It is the responsibility of the user
3
and Fittings
of this standard to establish appropriate safety and health
3
F412 Terminology Relating to Plastic Piping Systems
practices and determine the applicability of regulatory limita-
F1498 Specification for Taper Pipe Threads 60° for Ther-
tions prior to use.
3
moplastic Pipe and Fittings
2. Referenced Documents F1866 Specification for Poly (Vinyl Chloride) (PVC) Plas-
3
tic Schedule 40 Drainage and DWV Fabricated Fittings
2.1 ASTM Standards:
2
F2135 Specification for Molded Drain, Waste, and Vent-
D618 Practice for Conditioning Plastics for Testing
2
(DWV) Short-Pattern Plastic Fittings
D1599 Test Method for Resistance to Short-Time Hydrau-
3
lic Pressure of Plastic Pipe, Tubing, and Fittings
3. Terminology
D1600 Terminology for Abbreviated Terms Relating to
2
3.1 Definitions—DefinitionsareinaccordancewithTermi-
Plastics
nology F412F412, and abbreviations are in accordance with
Terminology D1600D1600, unless otherwise specified.
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
4. Significance and Use
Piping Systems and is the direct responsibility of Subcommittee F17.63 on DWV.
Current edition approved Sept. 10, 2002 Published November 2002. Originally
4.1 The requirements of this specification are intended to
published as D2665–68. Last previous edition D2665–02.
2
provide pipe and fittings suitable for the drainage and venting
Annual Book of ASTM Standards, Vol 08.01.
3
Annual Book of ASTM Standards, Vol 08.04. of sewage and certain other liquid wastes.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Please contact ASTM International (www.astm.org) for the latest information.
ϵ1
D 2665 – 02a
NOTE 1—Industrial waste disposal lines should be installed only with
6.2 Dimensions and Tolerances:
the specific approval of the cognizant building code authority since
6.2.1 Method—Alldimensionsshallbedeterminedinaccor-
chemicals not commonly found in drains and sew
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.