Standard Specification for Poly(Vinyl Chloride) (PVC) Profile Strip for Machine Spiral-Wound Liner Pipe Rehabilitation of Existing Sewers and Conduits

SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, stiffness factor, extrusion quality, and a form of marking for extruded poly(vinyl chloride) (PVC) profile strips used for machinemade field fabrication of spirally wound pipe liners in the rehabilitation of a variety of gravity applications such as sanitary sewers, storm sewers, and process piping in diameters of 6 to 48 in.
1.2 Profile strip produced to this specification is for use in field fabrication of spirally wound liner pipes in nonpressure sewer and conduit rehabilitation, where the spirally wound liner pipe is expanded until it presses against the interior surface of the existing sewer or conduit, or, alternatively, where the spirally wound liner pipe is inserted as a fixed diameter into the existing sewer or conduit and the annular space between the liner pipe and the existing sewer or conduit is grouted.
1.3 This specification includes extruded profile strips made only from materials specified in 5.1.
1.4 The values in parentheses are provided for information only.
1.5 The following precautionary caveat pertains only to the test method portion, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
09-May-2001
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F1697-01ae1 - Standard Specification for Poly(Vinyl Chloride) (PVC) Profile Strip for Machine Spiral-Wound Liner Pipe Rehabilitation of Existing Sewers and Conduits
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
An American National Standard
e1
Designation: F 1697 – 01a
Standard Specification for
Poly(Vinyl Chloride) (PVC) Profile Strip for Machine Spiral-
Wound Liner Pipe Rehabilitation of Existing Sewers and
12
Conduit
This standard is issued under the fixed designation F 1697; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1
e NOTE—Section 17 was added editorially in December 2002.
1. Scope 2. Referenced Documents
1.1 This specification covers requirements and test methods 2.1 ASTM Standards:
for materials, dimensions, workmanship, stiffness factor, ex- D 618 Practice for Conditioning Plastics and Electrical
3
trusion quality, and a form of marking for extruded poly(vinyl Insulating Materials for Testing
chloride) (PVC) profile strips used for machinemade field D 790 Test Methods for Flexural Properties of Unreinforced
fabrication of spirally wound pipe liners in the rehabilitation of and Reinforced Plastics and Electrical Insulating Materi-
3
a variety of gravity applications such as sanitary sewers, storm als
3
sewers, and process piping in diameters of 6 to 48 in. D 883 Terminology Relating to Plastics
1.2 Profile strip produced to this specification is for use in D 1600 Terminology for Abbreviated Terms Relating to
3
field fabrication of spirally wound liner pipes in nonpressure Plastics
sewer and conduit rehabilitation, where the spirally wound D 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
liner pipe is expanded until it presses against the interior Compounds and Chlorinated Poly(Vinyl Chloride)
3
surface of the existing sewer or conduit, or, alternatively, where (CPVC) Compounds
the spirally wound liner pipe is inserted as a fixed diameter into D 2122 Test Method for Determining Dimensions of Ther-
4
the existing sewer or conduit and the annular space between the moplastic Pipe and Fittings
liner pipe and the existing sewer or conduit is grouted. D 2152 Test Method for Adequacy of Fusion of Extruded
1.3 This specification includes extruded profile strips made Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
4
only from materials specified in 5.1. Acetone Immersion
1.4 The values in parentheses are provided for information F 412 Practice for Installation of Machine Spiral Wound
only. Poly Vinyl Chloride (PVC) Liner Pipe for Rehabilitation of
4
1.5 The following precautionary caveat pertains only to the Existing Sewers and Conduits
4
test method portion, Section 11, of this specification: This F 1741 Terminology Relating to Plastic Piping Systems
standard does not purport to address all of the safety concerns, 2.2 Federal Standard:
if any, associated with its use. It is the responsibility of the user Federal Standard No. 123 Marking for Shipment (Civil
5
of this standard to establish appropriate safety and health Agencies)
practices and determine the applicability of regulatory limita- 2.3 Military Standard:
5
tions prior to use. MIL-STD-129 Marking for Shipment and Storage
3. Terminology
1
3.1 General—Definitions are in accordance with Termi-
This specification is under the jurisdiction of ASTM Committee F17 on Plastic
Piping Systems and is the direct responsibility of Subcommittee F17.67 on nologies D 883 and F 412. Abbreviations are in accordance
Trenchless Plastic Pipeline Technology.
with Terminology D 1600, unless otherwise indicated.
Current edition approved May 10, 2001. Published August 2001.
3.2 Definitions of Terms Specific to This Standard:
Orignally published as F 1697–96. Last previous edition F 1697–01.
2
3.2.1 extruded PVC profile strips—a product, available in
The rehabilitation of existing pipelines and conduits by the insertion of a spiral
wound liner pipe is covered by patents. (RibLoc Group Limited, Dry Creek, South
various widths, consisting of a smooth inside surface and a
Australia, Australia and Danby of North America, Inc., Cary, NC, USA). Interested
parties are invited to submit information regarding the identification of acceptable
3
alternatives to this patented item to the Committee on Standards, ASTM Headquar- Annual Book of ASTM Standards, Vol 08.01.
4
ters, 100 Barr Harbor Drive, West Conshohocken, PA 19428-29590. Your comments Annual Book of ASTM Standards, Vol 08.04.
5
will receive careful consideration at a meeting of the responsible technical Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700
committee which you may attend. Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 -----
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.