Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings

ABSTRACT
This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, joining systems and a form of marking for type PSM poly(vinyl chloride) (PVC) sewer pipe and fittings. The pipe and fittings shall be homogeneous throughout and free from visible cracks, holes, foreign inclusions, or other injurious defects. The socket diameters, socket depth, wall thickness, pipe flattening, impact resistance, pipe stiffness, joint tightness, and extrusion quality shall be tested to meet the requirements prescribed.
SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, joining systems and a form of marking for type PSM poly(vinyl chloride) (PVC) sewer pipe and fittings.  
1.2 Pipe and fittings produced to this specification should be installed in accordance with Practice D2321.  
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.  
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.5 The following precautionary caveat pertains only to the test methods portion, Section 8, of this specification:   This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Oct-2016
Technical Committee
Drafting Committee
Current Stage
Ref Project

Buy Standard

Technical specification
ASTM D3034-16 - Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM D3034-16 - Standard Specification for Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:D3034 −16
Standard Specification for
Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and
1
Fittings
This standard is issued under the fixed designation D3034; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1. Scope* (CPVC) Compounds
D2122Test Method for Determining Dimensions of Ther-
1.1 This specification covers requirements and test methods
moplastic Pipe and Fittings
for materials, dimensions, workmanship, flattening resistance,
D2152Test Method for Adequacy of Fusion of Extruded
impact resistance, pipe stiffness, extrusion quality, joining
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
systems and a form of marking for type PSM poly(vinyl
Acetone Immersion
chloride) (PVC) sewer pipe and fittings.
D2321PracticeforUndergroundInstallationofThermoplas-
1.2 Pipeandfittingsproducedtothisspecificationshouldbe
tic Pipe for Sewers and Other Gravity-Flow Applications
installed in accordance with Practice D2321.
D2412Test Method for Determination of External Loading
Characteristics of Plastic Pipe by Parallel-Plate Loading
1.3 Thetextofthisspecificationreferencesnotes,footnotes,
and appendixes which provide explanatory material. These D2444Test Method for Determination of the Impact Resis-
tance of Thermoplastic Pipe and Fittings by Means of a
notesandfootnotes(excludingthoseintablesandfigures)shall
not be considered as requirements of the specification. Tup (Falling Weight)
D2564Specification for Solvent Cements for Poly(Vinyl
1.4 The values stated in inch-pound units are to be regarded
Chloride) (PVC) Plastic Piping Systems
as standard. The values given in parentheses are mathematical
D2749Symbols for Dimensions of Plastic Pipe Fittings
conversions to SI units that are provided for information only
D2855Practice for the Two-Step (Primer and Solvent Ce-
and are not considered standard.
ment) Method of Joining Poly (Vinyl Chloride) (PVC) or
1.5 The following precautionary caveat pertains only to the
Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and
test methods portion, Section 8, of this specification: This
Piping Components with Tapered Sockets
standard does not purport to address all of the safety concerns,
D3212Specification for Joints for Drain and Sewer Plastic
if any, associated with its use. It is the responsibility of the user
Pipes Using Flexible Elastomeric Seals
of this standard to establish appropriate safety and health
F412Terminology Relating to Plastic Piping Systems
practices and determine the applicability of regulatory limita-
F1336Specification for Poly(Vinyl Chloride) (PVC) Gas-
tions prior to use.
keted Sewer Fittings
3
2.2 Federal Standard:
2. Referenced Documents
Fed. Std. No. 123Marking for Shipment (Civil Agencies)
2
2.1 ASTM Standards:
3
2.3 Military Standard:
D618Practice for Conditioning Plastics for Testing
MIL-STD-129Marking for Shipment and Storage
D1600TerminologyforAbbreviatedTermsRelatingtoPlas-
tics
3. Terminology
D1784Specification for Rigid Poly(Vinyl Chloride) (PVC)
Compounds and Chlorinated Poly(Vinyl Chloride) 3.1 Definitions—Definitions are in accordance with Termi-
nology F412, and abbreviations are in accordance with Termi-
nology D1600, unless otherwise specified.The abbreviation of
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
poly(vinyl chloride) plastics is PVC.
Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
3.1.1 The term PSM is not an abbreviation but rather an
Current edition approved Nov. 1, 2016. Published December 2016. Originally
ɛ1
approved in 1972. Last previous edition approved in 2014 as D3034–15 . DOI:
arbitrary designation for a product having certain dimensions.
10.1520/D3034-16.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
3
Standards volume information, refer to the standard’s Document Summary page on Available from DLA Document Services Building 4/D 700 Robbins Avenue
the ASTM website. Philadelphia, PA 19111-5094 http://quicksearch.dla.mil/
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D3034−16
TABLE 1 Pipe Dimensions
4. Significance and Use
Outside Diameter Minimum Wall Thickness
4.1 The requirements of this specification are intended to
Nominal
Tolerance SDR DR SDR DR
Size
provide pipe and fitting
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
´1
Designation: D3034 − 15 D3034 − 16
Standard Specification for
Type PSM Poly(Vinyl Chloride) (PVC) Sewer Pipe and
1
Fittings
This standard is issued under the fixed designation D3034; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the U.S. Department of Defense.
1
ε NOTE—7.3.4 was editorially corrected in May 2016.
1. Scope*
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance,
impact resistance, pipe stiffness, extrusion quality, joining systems and a form of marking for type PSM poly(vinyl chloride) (PVC)
sewer pipe and fittings.
1.2 Pipe and fittings produced to this specification should be installed in accordance with Practice D2321.
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes
and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.5 The following precautionary caveat pertains only to the test methods portion, Section 8, of this specification: This standard
does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC)
Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2152 Test Method for Adequacy of Fusion of Extruded Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by Acetone
Immersion
D2321 Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications
D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
D2444 Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling
Weight)
D2564 Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems
D2749 Symbols for Dimensions of Plastic Pipe Fittings
D2855 Practice for the Two-Step (Primer and Solvent Cement) Method of Joining Poly (Vinyl Chloride) (PVC) or Chlorinated
Poly (Vinyl Chloride) (CPVC) Pipe and Piping Components with Tapered Sockets
D3212 Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals
F412 Terminology Relating to Plastic Piping Systems
F1336 Specification for Poly(Vinyl Chloride) (PVC) Gasketed Sewer Fittings
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.62 on Sewer.
Current edition approved Nov. 1, 2015Nov. 1, 2016. Published December 2015December 2016. Originally approved in 1972. Last previous edition approved in 2014 as
ɛ1
D3034 – 14a.D3034 – 15 . DOI: 10.1520/D3034-15E01.10.1520/D3034-16.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
D3034 − 16
3
2.2 Federal Standard:
Fed. Std. No. 123 Marking for Shipment (Civil Agencies)
3
2.3 Military Standard:
MIL-STD-129 Marking for Shipment and Storage
3. Terminology
3.1 Definitions—Definitions are in accordance with Terminology F412, and abbreviations are in accordance with Terminology
D1600, unless otherwise specified. The abbreviation of poly(vinyl chloride) plastics is PVC.
3.1
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.