Standard Specification for Glass Fiber Reinforced Polyethylene (PE-GF) Spiral Wound Large Diameter Pipe (Withdrawn 2016)

SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, joining systems, and marking for large diameter, 12 in. [300 mm] and larger, inside diameter controlled glass fiber reinforced polyethylene (PE-GF) spiral wound pipe with electrofusion joints. The piping is intended for new construction and renewal of existing piping systems used for the transport of water, slurries, municipal sewage, domestic sewage, effluents, etc., in pressure systems.
Note 1—Pipe produced to this specification should be installed in accordance with Practice D2774 or F1668, where applicable, and with the manufacturer’s recommendations.
1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard. Within the text the SI units are shown in brackets. The values stated in each system may not be exact equivalents: therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3 All pipes produced under this specification are pressure-rated.
1.4 This specification includes criteria for choice of raw material and test methods for evaluation of raw material, together with performance requirements and test methods for determining conformance with the requirements.
1.5 In referee decisions, the SI units shall be used for metric-sized pipe and inch-pound units for pipe sized per ANSI (ANSI B 36.10).
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Nov-2009
Technical Committee
Drafting Committee
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM F2720/F2720M-09 - Standard Specification for Glass Fiber Reinforced Polyethylene (PE-GF) Spiral Wound Large Diameter Pipe (Withdrawn 2016)
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM F2720/F2720M-09 - Standard Specification for Glass Fiber Reinforced Polyethylene (PE-GF) Spiral Wound Large Diameter Pipe (Withdrawn 2016)
English language
8 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:F2720/F2720M −09
StandardSpecification for
Glass Fiber Reinforced Polyethylene (PE-GF) Spiral Wound
1
Large Diameter Pipe
ThisstandardisissuedunderthefixeddesignationF2720/F2720M;thenumberimmediatelyfollowingthedesignationindicatestheyear
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 This specification covers requirements and test methods
D618 Practice for Conditioning Plastics for Testing
for materials, dimensions, workmanship, joining systems, and
D638 Test Method for Tensile Properties of Plastics
marking for large diameter, 12 in. [300 mm] and larger, inside
D790 Test Methods for Flexural Properties of Unreinforced
diameter controlled glass fiber reinforced polyethylene (PE-
and Reinforced Plastics and Electrical Insulating Materi-
GF) spiral wound pipe with electrofusion joints. The piping is
als
intended for new construction and renewal of existing piping
D792 Test Methods for Density and Specific Gravity (Rela-
systems used for the transport of water, slurries, municipal
tive Density) of Plastics by Displacement
sewage, domestic sewage, effluents, etc., in pressure systems.
D1505 Test Method for Density of Plastics by the Density-
NOTE 1—Pipe produced to this specification should be installed in
Gradient Technique
accordance with Practice D2774 or F1668, where applicable, and with the
D1598 Test Method for Time-to-Failure of Plastic Pipe
manufacturer’s recommendations.
Under Constant Internal Pressure
1.2 The values stated in either inch-pound units or SI units
D1600 Terminology forAbbreviatedTerms Relating to Plas-
are to be regarded separately as standard.Within the text the SI
tics
units are shown in brackets. The values stated in each system
D2122 Test Method for Determining Dimensions of Ther-
may not be exact equivalents: therefore, each system shall be
moplastic Pipe and Fittings
used independently of the other. Combining values from the
D2657 Practice for Heat Fusion Joining of Polyolefin Pipe
two systems may result in non-conformance with the standard.
and Fittings
D2774 PracticeforUndergroundInstallationofThermoplas-
1.3 All pipes produced under this specification are pressure-
tic Pressure Piping
rated.
D2837 Test Method for Obtaining Hydrostatic Design Basis
forThermoplasticPipeMaterialsorPressureDesignBasis
1.4 This specification includes criteria for choice of raw
for Thermoplastic Pipe Products
material and test methods for evaluation of raw material,
D3350 Specification for Polyethylene Plastics Pipe and Fit-
together with performance requirements and test methods for
tings Materials
determining conformance with the requirements.
D3895 Test Method for Oxidative-Induction Time of Poly-
1.5 In referee decisions, the SI units shall be used for
olefins by Differential Scanning Calorimetry
metric-sizedpipeandinch-poundunitsforpipesizedperANSI
F412 Terminology Relating to Plastic Piping Systems
(ANSI B 36.10).
F1290 PracticeforElectrofusionJoiningPolyolefinPipeand
Fittings
1.6 This standard does not purport to address all of the
F1668 Guide for Construction Procedures for Buried Plastic
safety concerns, if any, associated with its use. It is the
Pipe
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica- 2.2 ANSI Standard:
3
bility of regulatory limitations prior to use.
B36.10 Standard Dimensions of Steel Pipe (IPS)
1 2
This specification is under the jurisdiction ofASTM Committee F17 on Plastic For referenced ASTM standards, visit the ASTM website, www.astm.org, or
Piping Systems and is the direct responsibility of Subcommittee F17.11 on contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
Composite. Standards volume information, refer to the standard’s Document Summary page on
Current edition approved Dec. 1, 2009. Published March 2010. Originally the ASTM website.
3
approved in 2008. Last previous edition approved in 2008 as F2720/F2720M-08. Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
DOI:10.1520/F2720_F2720M-09. 4th Floor, New York, NY 10036, http://www.ansi.org.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
F2720/F2720M−09
TABLE 1 Physical Properties of PE-GF Material Tested as Pipe
Minimum
Property Test Method[s] Units
Value
3
Density ASTM D792 orD1505 g/cm 1.04
Oxidation Induction Time @ 412°F [200°C] ASTMD3895 minutes 20
Tensile strength @ yield (longitudinal dir
...

This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
An American National Standard
Designation:F2720/F2720M–08 Designation: F 2720/F 2720M – 09
Standard Specification for
Glass Fiber Reinforced Polyethylene (PE-GF) Spiral Wound
1
Large Diameter Pipe
This standard is issued under the fixed designation F 2720/F 2720M; the number immediately following the designation indicates the
year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last
reapproval. A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, joining systems, and
marking for large diameter, 12 in. [300 mm] and larger, inside diameter controlled glass fiber reinforced polyethylene (PE-GF)
spiral wound pipe with electrofusion joints. The piping is intended for new construction and renewal of existing piping systems
used for the transport of water, slurries, municipal sewage, domestic sewage, effluents, etc., in pressure systems.
NOTE 1—Pipe produced to this specification should be installed in accordance with Practice D2774 or Guide or F1668, where applicable, and with the
manufacturer’s recommendations.
1.2 The values stated in either inch-pound units or SI units are to be regarded separately as standard.Within the text the SI units
are shown in brackets. The values stated in each system may not be exact equivalents: therefore, each system shall be used
independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3 All pipes produced under this specification are pressure-rated.
1.4 This specification includes criteria for choice of raw material and test methods for evaluation of raw material, together with
performance requirements and test methods for determining conformance with the requirements.
1.5 In referee decisions, the SI units shall be used for metric-sized pipe and inch-pound units for pipe sized per ANSI (ANSI
B 36.10).
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D638 Test Method for Tensile Properties of Plastics
D790 Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials
D792 Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement
D1505 Test Method for Density of Plastics by the Density-Gradient Technique
D1598 Test Method for Time-to-Failure of Plastic Pipe Under Constant Internal Pressure
D1600 Terminology for Abbreviated Terms Relating to Plastics
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2657 Practice for Heat Fusion Joining of Polyolefin Pipe and Fittings
D2774 Practice for Underground Installation of Thermoplastic Pressure Piping
D2837 Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials or Pressure Design Basis for
Thermoplastic Pipe Products
D3350 Specification for Polyethylene Plastics Pipe and Fittings Materials
D3895 Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry
F412 Terminology Relating to Plastic Piping Systems
F1290 Practice for Electrofusion Joining Polyolefin Pipe and Fittings
F1668 Guide for Construction Procedures for Buried Plastic Pipe
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.11 on Composite.
Current edition approved Sept. 1, 2008. Published December 2008. DOI: 10.1520/F2720_F2720M-08.
Current edition approved Dec. 1, 2009. Published March 2010. Originally approved in 2008. Last previous edition approved in 2008 as F2720/F2720M-08.
DOI:10.1520/F2720_F2720M-09.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ---------------
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.