ASTM F3057-16
(Test Method)Standard Test Method for Electromagnetic Shielding Effectiveness of Glazings
Standard Test Method for Electromagnetic Shielding Effectiveness of Glazings
SIGNIFICANCE AND USE
5.1 This test method provides measurement procedures for determining the electromagnetic shielding effectiveness of glazings and glazing configurations as a material. This test method specifies a method for comparing the glazings and glazing configurations as an infill component to allow comparison of between different infills. In addition, this test method is written to minimize variations in measured shielding effectiveness at a given frequency and test point regardless of test personnel, equipment, and test site. Therefore, the shielding effectiveness of a glazing or glazing configuration from any supplier can be determined. This test method specifies a minimum set of measurements over a frequency range to determine shielding effectiveness.
5.2 Source Fields—Performance of a shielded enclosure and glazing or glazing configurations are to be assessed for three source fields: magnetic, electric, and plane wave.
SCOPE
1.1 This test method covers the determination of the electromagnetic shielding effectiveness of glazings or glazing configurations.
1.1.1 The intended application of this test method is for glazings or glazing configurations to be evaluated for their transmittance or shielding capability to electromagnetic frequencies.
1.1.2 This is a component test. It is not applicable to full systems such as walls, floors, ceilings, shielded racks, or window systems.
1.1.3 The intention of this test method is to standardize a measurement procedure for glazings or glazing configurations, with and without coatings, films, interlayers, or other enhancements, as single or insulating units at a standard size and when mounted in a standardized frame.
1.1.4 This test method is to provide a means of generating data for the glazing or glazing configuration infills that can be used by the consumer, designer, and system manufacturer to understand the capability and contribution of glazings or glazing configurations to a system used for Electromagnetic Interference (EMI) security.
1.2 This test method is for use in the assessment of EMI transmittance for frequency ranges 100 kHz to 20 GHz. Specific test frequencies within these ranges are required.
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Some specific hazards statements are given in Section 8 on Hazards.
General Information
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: F3057 − 16
Standard Test Method for
1
Electromagnetic Shielding Effectiveness of Glazings
This standard is issued under the fixed designation F3057; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
2
2.1 ASTM Standards:
1.1 This test method covers the determination of the elec-
E631 Terminology of Building Constructions
tromagnetic shielding effectiveness of glazings or glazing
3
configurations.
2.2 IEEE Standards:
IEEE Standard 299–1977 IEEE Standard Method for Mea-
1.1.1 The intended application of this test method is for
suring the Effectiveness of Electromagnetic Shielding
glazings or glazing configurations to be evaluated for their
Enclosures
transmittance or shielding capability to electromagnetic fre-
IEEE STD C95.1–1991 IEEE Standard for Safety Levels
quencies.
with Respect to Human Exposure to Radio Frequency
1.1.2 This is a component test. It is not applicable to full
Electromagnetic Fields, 3 kHz to 300 GHz
systems such as walls, floors, ceilings, shielded racks, or
4
window systems.
2.3 OSHA Standard:
OSHARegulation, 29 CFR 1910 Department of Labor, July
1.1.3 The intention of this test method is to standardize a
1992
measurement procedure for glazings or glazing configurations,
5
with and without coatings, films, interlayers, or other
2.4 ANSI Standard:
enhancements, as single or insulating units at a standard size
ANSI/NCSL Z540.3 Requirements for the Calibration of
and when mounted in a standardized frame.
Measuring and Test Equipment
6
1.1.4 This test method is to provide a means of generating
2.5 ISO Standard:
data for the glazing or glazing configuration infills that can be
ISO/IEC 17025:2005 General Requirements for the Compe-
used by the consumer, designer, and system manufacturer to
tence of Testing and Calibration Laboratories
understand the capability and contribution of glazings or
glazing configurations to a system used for Electromagnetic
3. Terminology
Interference (EMI) security.
3.1 Definitions:
1.2 This test method is for use in the assessment of EMI
3.1.1 accredited independent testing laboratory—testing
transmittance for frequency ranges 100 kHz to 20 GHz.
laboratory accredited to perform the referenced testing proce-
Specific test frequencies within these ranges are required.
dures by a nationally recognized accrediting agency in accor-
dance with ISO/IEC 17025 and led by a test director.
1.3 Units—The values stated in SI units are to be regarded
3.1.2 electric field measurements—the attenuation provided
as standard. No other units of measurement are included in this
by a glazing or glazing configuration is assessed by using a
standard.
local source to generate the electric field. The electric field
1.4 This standard does not purport to address all of the
measurement will be from 1 to 100 MHz.
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appro-
priate safety and health practices and determine the applica-
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
bility of regulatory limitations prior to use. Some specific
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
hazards statements are given in Section 8 on Hazards.
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website.
3
Available from Institute of Electrical and Electronics Engineers, Inc. (IEEE),
445 Hoes Ln., Piscataway, NJ 08854, http://www.ieee.org.
1 4
This test method is under the jurisdiction ofASTM Committee F12 on Security Available from Occupational Safety and Health Administration (OSHA), 200
Systems and Equipment and is the direct responsibility of Subcommittee F12.10 on Constitution Ave., Washington, DC 20210, http://www.osha.gov.
5
Systems Products and Services. Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
Current edition approved Feb. 1, 2016. Published March 2016. Originally 4th Floor, New York, NY 10036, http://www.ansi.org.
6
approved in 2014. Last previous edition approved in 2014 as F3057 – 14. DOI: Available from International Organization for Standardization (ISO), 1, ch. de
10.1520/F3057-16. la Voie-Creuse, CP 56, CH-1211 Geneva 20, Switzerland, http://www.iso.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
F3057 − 16
3.1.3 magnetic field measurements—the attenuation pro- method specifies a method for comparing the glazings and
videdbyaglazin
...
This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: F3057 − 14 F3057 − 16
Standard Test Method for
1
Electromagnetic Shielding Effectiveness of Glazings
This standard is issued under the fixed designation F3057; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This test method covers the determination of the electromagnetic shielding effectiveness of glazings or glazing
configurations.
1.1.1 The intended application of this test method is for glazings or glazing configurations to be evaluated for their transmittance
or shielding capability to electromagnetic frequencies.
1.1.2 This is a component test. It is not applicable to full systems such as walls, floors, ceilings, shielded racks, or window
systems.
1.1.3 The intention of this test method is to standardize a measurement procedure for glazings or glazing configurations, with
and without coatings, films, interlayers, or other enhancements, as single or insulating units at a standard size and when mounted
in a standardized frame.
1.1.4 This test method is to provide a means of generating data for the glazing or glazing configuration infills that can be used
by the consumer, designer, and system manufacturer to understand the capability and contribution of glazings or glazing
configurations to a system used for Electromagnetic Interference (EMI) security.
1.2 This test method is for use in the assessment of EMI transmittance for frequency ranges 100 kHz to 20 GHz. Specific test
frequencies within these ranges are required.
1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this
standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use. Some specific hazards statements are given in Section 8 on Hazards.
2. Referenced Documents
2
2.1 ASTM Standards:
E631 Terminology of Building Constructions
3
2.2 IEEE Standards:
IEEE Standard 299–1977 IEEE Standard Method for Measuring the Effectiveness of Electromagnetic Shielding Enclosures
IEEE STD C95.1–1991 IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic
Fields, 3 kHz to 300 GHz
4
2.3 OSHA Standard:
OSHA Regulation, 29 CFR 1910 Department of Labor, July 1992
5
2.4 ANSI Standard:
ANSI/NCSL Z540.3 Requirements for the Calibration of Measuring and Test Equipment
6
2.5 ISO Standard:
ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories
1
This test method is under the jurisdiction of ASTM Committee F12 on Security Systems and Equipment and is the direct responsibility of Subcommittee F12.10 on
Systems Products and Services.
Current edition approved April 15, 2014Feb. 1, 2016. Published May 2014March 2016. Originally approved in 2014. Last previous edition approved in 2014 as F3057 – 14.
DOI: 10.1520/F3057-14.10.1520/F3057-16.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from Institute of Electrical and Electronics Engineers, Inc. (IEEE), 445 Hoes Ln., Piscataway, NJ 08854, http://www.ieee.org.
4
Available from Occupational Safety and Health Administration (OSHA), 200 Constitution Ave., Washington, DC 20210, http://www.osha.gov.
5
Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.
6
Available from International Organization for Standardization (ISO), 1, ch. de la Voie-Creuse, CP 56, CH-1211 Geneva 20, Switzerland, http://www.iso.org.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1
---------------------- Page: 1 ----------------------
F3057 − 16
3. Terminology
3.1 Definitions:
3.1.1 accredited independent testing laboratory—testing laboratory accredited to perform the referenced testing procedures by
a nationally recognized accrediting agency in accordance with ISO/IEC 17025 and led by a test director.
3.1.2 electric field measurem
...