ASTM D2665-08b
(Specification)Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings
Standard Specification for Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings
ABSTRACT
This specification covers requirements and test methods for materials, dimensions and tolerances, pipe stiffness, crush resistance, impact resistance, hydrostatic burst resistance, and solvent cement for poly(vinyl chloride) plastic drain, waste, and vent pipe and fittings. The pipe and fittings covered are suitable for the drainage and venting of sewage and certain other liquid wastes. A form of marking is also included. The pipe and fittings shall be made of virgin PVC compounds of defined specification. The pipe shall conform to the required stiffness, deflection load and flattening. The fittings shall be subject to hydrostatic burst pressure. The pipe and fittings shall be subject to impact resistance test.
SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions and tolerances, pipe stiffness, crush resistance, impact resistance, and solvent cement for poly(vinyl chloride) plastic drain, waste, and vent pipe and fittings. A form of marking is also included. Plastic which does not meet the material requirements specified in Section 5 is excluded. Installation procedures are given in the Appendix.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.4 The following safety hazards caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
An American National Standard
Designation: D 2665 – 08b
Standard Specification for
Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent
1
Pipe and Fittings
This standard is issued under the fixed designation D2665; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope* D1784 SpecificationforRigidPoly(VinylChloride)(PVC)
Compounds and Chlorinated Poly(Vinyl Chloride)
1.1 This specification covers requirements and test methods
(CPVC) Compounds
for materials, dimensions and tolerances, pipe stiffness, crush
D2122 Test Method for Determining Dimensions of Ther-
resistance,impactresistance,andsolventcementforpoly(vinyl
moplastic Pipe and Fittings
chloride)plasticdrain,waste,andventpipeandfittings.Aform
D2412 TestMethodforDeterminationofExternalLoading
of marking is also included. Plastic which does not meet the
Characteristics of Plastic Pipe by Parallel-Plate Loading
material requirements specified in Section 5 is excluded.
D2444 Test Method for Determination of the Impact Re-
Installation procedures are given in the Appendix.
sistance ofThermoplastic Pipe and Fittings by Means of a
1.2 Thevaluesstatedininch-poundunitsaretoberegarded
Tup (Falling Weight)
as standard. The values given in parentheses are mathematical
D2564 Specification for Solvent Cements for Poly(Vinyl
conversions to SI units that are provided for information only
Chloride) (PVC) Plastic Piping Systems
and are not considered standard.
D3311 Specification for Drain, Waste, and Vent (DWV)
1.3 Thetextofthisspecificationreferencesnotes,footnotes,
Plastic Fittings Patterns
and appendixes which provide explanatory material. These
D4396 SpecificationforRigidPoly(VinylChloride)(PVC)
notesandfootnotes(excludingthoseintablesandfigures)shall
and Chlorinated Poly(Vinyl Chloride) (CPVC) Com-
not be considered as requirements of the specification.
pounds for Plastic Pipe and Fittings Used in Nonpressure
1.4 The following safety hazards caveat pertains only to the
Applications
test methods portion, Section 7, of this specification: This
F402 Practice for Safe Handling of Solvent Cements,
standard does not purport to address all of the safety concerns,
Primers,andCleanersUsedforJoiningThermoplasticPipe
if any, associated with its use. It is the responsibility of the user
and Fittings
of this standard to establish appropriate safety and health
F412 Terminology Relating to Plastic Piping Systems
practices and determine the applicability of regulatory limita-
F1498 Specification for Taper Pipe Threads 60° for Ther-
tions prior to use.
moplastic Pipe and Fittings
2. Referenced Documents F1866 Specification for Poly (Vinyl Chloride) (PVC) Plas-
2
tic Schedule 40 Drainage and DWV Fabricated Fittings
2.1 ASTM Standards:
F2135 Specification for Molded Drain, Waste, and Vent
D618 Practice for Conditioning Plastics for Testing
(DWV) Short-Pattern Plastic Fittings
D1600 Terminology for Abbreviated Terms Relating to
Plastics
3. Terminology
3.1 Definitions—DefinitionsareinaccordancewithTermi-
nology F412, and abbreviations are in accordance with Ter-
1
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
minology D1600, unless otherwise specified.
Piping Systems and is the direct responsibility of Subcommittee F17.63 on DWV.
Current edition approved Nov. 1, 2008 Published November 2008. Originally
4. Significance and Use
approved in 1968. Last previous edition approved in 2008 as D2665–08a.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
4.1 The requirements of this specification are intended to
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
provide pipe and fittings suitable for the drainage and venting
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. of sewage and certain other liquid wastes.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
D 2665 – 08b
NOTE 1—Industrial waste disposal lines should be installed only with
6.3.1.1 Pipe Stiffness (PS)—Three specimens shall be
the specific approval of the cognizant building code authority since
tested. If all three meet the PS requirement, the sample meets
chemicals not commonly found in drains and sewers and temperatures in
the PS requirement. If one or two fail, additional testing shall
excess of 180°F (82.2°C) may be encountered.
be co
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
An American National Standard
Designation:D2665–08a Designation: D 2665 – 08b
Standard Specification for
Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent
1
Pipe and Fittings
This standard is issued under the fixed designation D2665; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope*
1.1 This specification covers requirements and test methods for materials, dimensions and tolerances, pipe stiffness, crush
resistance, impact resistance, and solvent cement for poly(vinyl chloride) plastic drain, waste, and vent pipe and fittings.Aform
of marking is also included. Plastic which does not meet the material requirements specified in Section 5 is excluded. Installation
procedures are given in the Appendix.
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.3 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes
and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.4 Thefollowingsafetyhazardscaveatpertainsonlytothetestmethodsportion,Section7,ofthisspecification: This standard
does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this
standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
D618 Practice for Conditioning Plastics for Testing
D1600 Terminology for Abbreviated Terms Relating to Plastics
D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC)
Compounds
D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings
D2412 Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading
D2444 TestMethodforDeterminationoftheImpactResistanceofThermoplasticPipeandFittingsbyMeansofaTup(Falling
Weight)
D2564 Specification for Solvent Cements for Poly(Vinyl Chloride) (PVC) Plastic Piping Systems
D3311 Specification for Drain, Waste, and Vent (DWV) Plastic Fittings Patterns
D4396 Specification for Rigid Poly(Vinyl Chloride) (PVC) and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds for
Plastic Pipe and Fittings Used in Nonpressure Applications
F402 Practice for Safe Handling of Solvent Cements, Primers, and Cleaners Used for JoiningThermoplastic Pipe and Fittings
F412 Terminology Relating to Plastic Piping Systems
F1498 Specification for Taper Pipe Threads 60 for Thermoplastic Pipe and Fittings
F1866 Specification for Poly (Vinyl Chloride) (PVC) Plastic Schedule 40 Drainage and DWV Fabricated Fittings
F2135 Specification for Molded Drain, Waste, and Vent (DWV) Short-Pattern Plastic Fittings
3. Terminology
3.1 Definitions—DefinitionsareinaccordancewithTerminologyF412,andabbreviationsareinaccordancewithTerminology
D1600, unless otherwise specified.
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.63 on DWV.
Current edition approved Sept.Nov. 1, 2008 Published SeptemberNovember 2008. Originally approved in 1968. Last previous edition approved in 2008 as D2665–08a.
2
ForreferencedASTMstandards,visittheASTMwebsite,www.astm.org,orcontactASTMCustomerServiceatservice@astm.org.For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
D 2665 – 08b
4. Significance and Use
4.1 The requirements of this specification are intended to provide pipe and fittings suitable for the drainage and venting of
sewage and certain other liquid wastes.
NOTE 1—Industrial waste disposal lines should be installed only with the specific approval of the cognizant building code authority since
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.