Standard Specification for Coal Tar Primer Used in Roofing, Dampproofing, and Waterproofing

ABSTRACT
This specification covers coal tar primer suitable for use with coal tar pitch in roofing, dampproofing, and waterproofing below or above ground level, for application to concrete, masonry, and coal tar surfaces. Different tests shall be conducted in order to determine the following physical properties of coal tar primer: water content, consistency, specific gravity, matter insoluble in benzene, distillation, and coke residue content.
SCOPE
^SCOPE:
1.1 This specification covers coal tar primer suitable for use with coal tar pitch in roofing, dampproofing, and waterproofing below or above ground level, for application to concrete, masonry, and coal tar surfaces.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
30-Apr-2012
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM D43/D43M-00(2012)e1 - Standard Specification for Coal Tar Primer Used in Roofing, Dampproofing, and Waterproofing
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Technical specification
REDLINE ASTM D43/D43M-00(2012)e1 - Standard Specification for Coal Tar Primer Used in Roofing, Dampproofing, and Waterproofing
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
´1
Designation:D43/D43M −00 (Reapproved 2012) American Association State
Highway and Transportation Officials Standard
AASHTO No.: M121
Standard Specification for
Coal Tar Primer Used in Roofing, Dampproofing, and
Waterproofing
This standard is issued under the fixed designation D43/D43M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
´ NOTE—Units information was editorially corrected in June 2012.
1. Scope D367 Test Method for Xylene-Insoluble Matter in Creosote
(Withdrawn 2006)
1.1 This specification covers coal tar primer suitable for use
D368 Test Method for Specific Gravity of Creosote and
withcoaltarpitchinroofing,dampproofing,andwaterproofing
Oil-Type Preservatives (Withdrawn 2006)
below or above ground level, for application to concrete,
D370 Practice for Dehydration of Oil-Type Preservatives
masonry, and coal tar surfaces.
3. Physical Requirements
1.2 The values stated in either SI units or inch-pound units
are to be regarded separately as standard. The values stated in
3.1 Coal tar primer shall be a distillate of coal-gas tar or
each system may not be exact equivalents; therefore, each
coke-oventarandshallconformtothefollowingrequirements:
system shall be used independently of the other. Combining
values from the two systems may result in non-conformance
Water not more than 1 %
A
Consistency at 5°C [41°F] entirely fluid and crystal free
with the standard.
Specific gravity, 38/15.5°C [100/60°F ] not less than 1.06
1.3 This standard does not purport to address all of the
Matter insoluble in benzene not more than 0.5 %
Distillation, based on water-free oil:
safety concerns, if any, associated with its use. It is the
Up to 210°C [410°F] not more than 1 %
responsibility of the user of this standard to establish appro-
Up to 235°C [455°F] not more than 10 %
priate safety and health practices and determine the applica- Up to 355°C [670°F] not less than 65 %
Coke residue not more than 2 %
bility of regulatory limitations prior to use.
A
2. Referenced Documents The coal tar primer shall be rated as crystal free if no crystals are formed when
100 mL of the sample is maintained at a temperature of 5°C [41°F] for 3 h, in a 125
2.1 ASTM Standards:
mL Erlenmeyer flask, with occasional stirring.
D140 Practice for Sampling Bituminous Materials
4. Sampling
D168 Test Method for Coke Residue of Creosote (With-
4.1 Sample the coal tar primer in accordance with Practice
drawn 2006)
D246 TestMethodforDistillationofCreosoteandCreosote- D140.
Coal Tar Solutions (Withdrawn 2006)
5. Test Methods
D347 Tables for Volume and Specific Gravity Correction for
5.1 Determine the properties enumerated in this specifica-
Creosote, Creosote-Coal Tar Solution, and Coal Tar
tion in accordance with the following methods:
(Withdrawn 2006)
5.1.1 Water—Test Method D370.
5.1.2 Specific Gravity—Test Method D368.
This specification is under the jurisdiction of ASTM Committee D08 on
Roo
...


This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
American Association State
Designation:D43–00 (Reapproved 2006) Designation: D43/D43MHighway and–Transportation00 (ReapprovedOfficials Standard
´1
AASHTO No.: M121
2012)
Standard Specification for
Coal Tar Primer Used in Roofing, Dampproofing, and
Waterproofing
This standard is issued under the fixed designation D43/D43M; the number immediately following the designation indicates the year
of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.
A superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
´ NOTE—Units information was editorially corrected in June 2012.
1. Scope
1.1 This specification covers coal tar primer suitable for use with coal tar pitch in roofing, dampproofing, and waterproofing
below or above ground level, for application to concrete, masonry, and coal tar surfaces.
1.2The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each
system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the
two systems may result in non-conformance with the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:
D140 Practice for Sampling Bituminous Materials
D168 Test Method for Coke Residue of Creosote
D246 Test Method for Distillation of Creosote and Creosote-Coal Tar Solutions
D347 Tables for Volume and Specific Gravity Correction for Creosote, Creosote-Coal Tar Solution, and Coal Tar
D367 Test Method for Xylene-Insoluble Matter in Creosote
D368 Test Method for Specific Gravity of Creosote and Oil-Type Preservatives
D370 Practice for Dehydration of Oil-Type Preservatives
3. Physical Requirements
3.1 Coal tar primer shall be a distillate of coal-gas tar or coke-oven tar and shall conform to the following requirements:
Water not more than 1 %
A
Consistency at 5°C (41°F) entirely fluid and crystal free
A
Consistency at 5°C [41°F] entirely fluid and crystal free
Specific gravity, 38/15.5°C (100/ not less than 1.06
60°F )
Specific gravity, 38/15.5°C [100/ not less than 1.06
60°F ]
Matter insoluble in benzene not more than 0.5 %
Distillation, based on water-free
oil:
Up to 210°C (410°F) not more than 1 %
This specification is under the jurisdiction of ASTM Committee D08 on Roofing and Waterproofing and is the direct responsibility of Subcommittee D08.05 on
Solvent-Bearing Bituminous Compounds for Roofing and Waterproofing.
Current edition approved Dec. 1, 2006. Published December 2006. Originally approved in 1917. Last previous edition approved in 2000 as D43–00. DOI:
10.1520/D0043-00R06.
Current edition approved May 1, 2012. Published June 2012. Originally approved in 1917. Last previous edition approved in 2006 as D43 – 00 (2006
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.