ASTM D2949-01a
(Specification)Standard Specification for 3.25-in. Outside Diameter Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings
Standard Specification for 3.25-in. Outside Diameter Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings
SCOPE
1.1 This specification covers requirements and test methods for materials, dimensions and tolerances, deflection load, crush resistance, hydrostatic-burst resistance, flattening resistance, impact resistance, and solvent cement. A form of marking is also included. Plastic which does not meet the material requirements specified in Section 5 is excluded.
Note 1—This specification was formerly issued under the title, 3-in. Thin Wall Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings.
Note 2—Techniques for making solvent-cement joints are given in Practice D 2855.
1.2 The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.3 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.
1.4 The following precautionary caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
An American National Standard
Designation: D 2949 – 01a
Standard Specification for
3.25-in. Outside Diameter Poly(Vinyl Chloride) (PVC) Plastic
1
Drain, Waste, and Vent Pipe and Fittings
This standard is issued under the fixed designation D 2949; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
This standard has been approved for use by agencies of the Department of Defense.
1. Scope D1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)
Compounds and Chlorinated Poly(Vinyl Chloride)
1.1 This specification covers requirements and test methods
2
(CPVC) Compounds
formaterials,dimensionsandtolerances,deflectionload,crush
D2122 Test Method for Determining Dimensions of Ther-
resistance, hydrostatic-burst resistance, flattening resistance,
3
moplastic Pipe and Fittings
impact resistance, and solvent cement. A form of marking is
D2152 Test Method for Adequacy of Fusion of Extruded
also included. Plastic which does not meet the material
Poly(Vinyl Chloride) (PVC) Pipe and Molded Fittings by
requirements specified in Section 5 is excluded.
3
Acetone Immersion
NOTE 1—This specification was formerly issued under the title, 3-in.
D2412 TestMethodforDeterminationofExternalLoading
ThinWallPoly(VinylChloride)(PVC)PlasticDrain,Waste,andVentPipe
3
Characteristics of Plastic Pipe by Parallel-Plate Loading
and Fittings.
D2444 Test Method for Determination of the Impact Re-
NOTE 2—Techniques for making solvent-cement joints are given in
sistance of Thermoplastic Pipe and Fittings by Means of a
Practice D2855.
3
Tup (Falling Weight)
1.2 Thetextofthisspecificationreferencesnotes,footnotes,
D2564 Specification for Solvent Cements for Poly(Vinyl
and appendixes which provide explanatory material. These
3
Chloride) (PVC) Plastic Piping Systems
notesandfootnotes(excludingthoseintablesandfigures)shall
D2855 Practice for Making Solvent-Cemented Joints with
not be considered as requirements of the specification.
3
Poly(Vinyl Chloride) (PVC) Pipe and Fittings
1.3 The values stated in inch-pound units are to be regarded
D3311 Specification for Drain, Waste, and Vent (DWV)
as the standard. The values given in parentheses are for
3
Plastic Fittings Patterns
information only.
F402 Practice for Safe Handling of Solvent Cements,
1.4 The following precautionary caveat pertains only to the
Primers,andCleanersUsedforJoiningThermoplasticPipe
test methods portion, Section 7, of this specification: This
3
and Fittings
standard does not purport to address all of the safety concerns,
3
F412 Terminology Relating to Plastic Piping Systems
if any, associated with its use. It is the responsibility of the user
F1498 Specification for Taper Pipe Threads 60° for Ther-
of this standard to establish appropriate safety and health
3
moplastic Pipe and Fittings
practices and determine the applicability of regulatory limita-
tions prior to use.
3. Terminology
3.1 Definitions—Definitions are in accordance with Termi-
2. Referenced Documents
nology F412, and abbreviations are in accordance with Ter-
2.1 ASTM Standards:
minology D1600, unless otherwise specified.
2
D618 Practice for Conditioning Plastics for Testing
D1599 Test Method for Resistance to Short-Time Hydrau-
4. Significance and Use
3
lic Pressure of Plastic Pipe, Tubing, and Fittings
4.1 The requirements of this specification are intended to
D1600 Terminology for Abbreviated Terms Relating to
provide pipe and fittings suitable for drainage of sewage and
2
Plastics
certain other liquid wastes where toughness, resistance to
deterioration from water and chemicals, flattening and aging
1 resistance, and strong tight joints are required.
This specification is under the jurisdiction ofASTM Committee F17 on Plastic
Piping Systems and is the direct responsibility of Subcommittee F17.63 on DWV.
Current edition approved Dec. 10, 2001. Published February 2002. Originally
published as D2949–71. Last previous edition D2949–01.
2
Annual Book of ASTM Standards, Vol 08.01.
3
Annual Book of ASTM Standards, Vol 08.04.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ----------------------
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact ASTM
International (www.astm.org) for the latest information.
D 2949 – 01a
NOTE 4—Additional fittings in IPS dimensions are included in Speci-
4.2 When joining 3.25-in. outside diameter PVC DWV
fication D3311.
piping to 3-in. Schedule 40 PVC DWV piping, it is necessary
to use either reducer bushings or increasers, as shown in the
6.3 Deflection Load
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.