Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units

This European Standard specifies characteristics and related requirements, assessment methods, the marking and assessment and verification of constancy of performance (AVCP) procedures for prefabricated tertiary treatment units used for populations up to 50 inhabitants.
Prefabricated tertiary treatment units in accordance with this European Standard are: - used for the tertiary treatment of domestic wastewater by biological, physical, chemical, electrical processes and coming from: a) products in accordance with EN 12566 3 or EN 12566 6 or;
b) installation designed and constructed in accordance with CEN/TR 12566-5.
NOTE   Equivalent secondary treated effluent may come from existing systems.
- made of concrete, steel, PVC-U, Polyethylene (PE), Polypropylene (PP), Glass Reinforced Polyester (GRP-UP), Polydicyclopentadiene (PDCPD), PVC and/or EPDM; - used on the top of the ground (outside the building) or buried in the ground; - with or without extension shaft;
- made of prefabricated components that are factory or site-assembled by one manufacturer and which are tested as a whole.
This European Standard does not cover prefabricated tertiary treatment units: - where vehicle loads apply to it; - with direct infiltration into the ground (non-watertight); - made of retrofit kits (see definition in 3.1.11); - forming part of products covered by EN 12566-3 and EN 12566-6; - for microorganism reduction.
The assessment methods specified in this European Standard establish the performance of the prefabricated tertiary treatment unit, needed to verify its suitability for the condition in which it is normally installed.

Kleinkläranlagen für bis zu 50 EW - Teil 7: Vorgefertigte Anlagen für eine dritte Reinigungsstufe

Dieses Dokument legt die Merkmale und die damit in Zusammenhang stehenden Anforderungen, Bewertungsverfahren, die Kennzeichnung und die Verfahren zur Bewertung und Überprüfung der Leistungsbeständigkeit (AVCP) für vorgefertigte Anlagen für eine dritte Reinigungsstufe für bis zu 50 EW fest.
Vorgefertigte Anlagen für eine dritte Reinigungsstufe nach diesem Dokument
— werden für die dritte Reinigungsstufe von häuslichem Schmutzwasser aus
a) Produkten nach EN 12566-3 oder EN 12566-6 oder
b) Anlagen verwendet, die nach CEN/TR 12566-5 geplant und gebaut wurden.
Gleichwertiges Abwasser der zweiten Reinigungsstufe kann aus bestehenden Anlagen stammen.
— bestehen aus Beton, Stahl, weichmacherfreiem Polyvinylchlorid (PVC-U), Polyethylen (PE), Polypropylen (PP), glasfaserverstärktem Kunststoff (GFK-UP), Polydicyclopentadien (PDCPD), PVC und/oder EPDM,
— werden in den Boden eingebaut,
— sind mit oder ohne Schachtverlängerung,
— bestehen aus vorgefertigten und/oder vor Ort montierten Komponenten, die durch einen Hersteller als Bausatz auf den Markt gebracht und als Ganzes geprüft werden.
Dieses Dokument gilt nicht für vorgefertigte Anlagen für eine dritte Reinigungsstufe,
— wenn sie Fahrzeuglasten ausgesetzt sind,
— wenn direkte Infiltration in den Boden stattfindet (nicht wasserdicht),
— wenn sie aus Nachrüstsätzen (siehe Definition in 3.1.9) bestehen,
— wenn sie Teil von Produkten sind, die durch EN 12566-3 und EN 12566-6 abgedeckt sind,
— die zur Reduzierung der Mikroorganismen dienen.
Die in diesem Dokument festgelegten Bewertungsverfahren bestimmten die Leistung der vorgefertigten Anlage für eine dritte Reinigungsstufe, die erforderlich ist, um ihre Eignung für die Bedingungen, in denen sie üblicherweise eingebaut wird, nachzuweisen.

Petites installations de traitement des eaux usées pour une population totale équivalente (PTE) jusqu’à 50 habitants - Partie 7 : Unités préfabriquées de traitement tertiaire

Le présent document spécifie les caractéristiques et les exigences associées, les méthodes d’évaluation, le marquage et les modes opératoires d’évaluation et de vérification de la constance des performances (EVCP) applicables aux unités préfabriquées de traitement tertiaire utilisées pour des populations allant jusqu’à 50 habitants.
Les unités préfabriquées de traitement tertiaire conformes au présent document sont :
 utilisées pour le traitement tertiaire des eaux usées domestiques provenant :
a) de produits conformes à l’EN 12566-3 ou l’EN 12566-6 ; ou
b) d’installations conçues et construites conformément au CEN/TR 12566-5.
Un effluent secondaire équivalent peut provenir de systèmes existants :
 fabriquées en béton, acier, polychlorure de vinyle non plastifié (PVC-U), polyéthylène (PE), polypropylène (PP), polyester renforcé de verre (PRV-UP), polydicyclopentadiène (PDCPD), PVC et/ou EPDM ;
 enterrées dans le sol ;
 équipées ou dépourvues d’une rehausse ;
 fabriquées avec des composants qui sont préfabriqués en usine ou assemblés sur site par un même fabricant et qui sont soumis aux essais comme un tout.
Le présent document ne traite pas des unités préfabriquées de traitement tertiaire :
 soumises à des charges dues aux véhicules ;
 à infiltration directe dans le sol (non étanches à l’eau) ;
 équipées de kits de remise à niveau (voir définition en 3.1.9) ;
 faisant partie de produits couverts par l’EN 12566-3 et l’EN 12566-6 ;
 destinées à la réduction des microorganismes.
Les méthodes d’évaluation spécifiées dans le présent document établissent les performances des unités préfabriquées de traitement tertiaire, qui sont requises pour vérifier leur aptitude à l’emploi dans les conditions d’installation normale.

Male čistilne naprave do 50 PE - 7. del: Predizdelane čistilne enote za terciarno čiščenje

General Information

Status
Not Published
Publication Date
30-Nov-2020
Withdrawal Date
30-Nov-2020
Current Stage
4098 - Decision to abandon - Enquiry
Due Date
30-Dec-2024
Completion Date
14-Jun-2019

Buy Standard

Draft
prEN 12566-7:2018
English language
82 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN 12566-7:2018
01-december-2018
0DOHþLVWLOQHQDSUDYHGR3(GHO3UHGL]GHODQHþLVWLOQHHQRWH]DWHUFLDUQR
þLãþHQMH
Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary
treatment units
Kleinkläranlagen für bis zu 50 EW - Teil 7: Vorgefertigte Anlagen für eine dritte
Reinigungsstufe
Petites installations de traitement des eaux usées pour une population totale équivalente
(PTE) jusqu’à 50 habitants - Partie 7 : Unités préfabriquées de traitement tertiaire
Ta slovenski standard je istoveten z: prEN 12566-7
ICS:
13.060.30 Odpadna voda Sewage water
oSIST prEN 12566-7:2018 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN 12566-7:2018

---------------------- Page: 2 ----------------------
oSIST prEN 12566-7:2018


DRAFT
EUROPEAN STANDARD
prEN 12566-7
NORME EUROPÉENNE

EUROPÄISCHE NORM

October 2018
ICS 13.060.30 Will supersede EN 12566-7:2016
English Version

Small wastewater treatment systems for up to 50 PT - Part
7: Prefabricated tertiary treatment units
Petites installations de traitement des eaux usées pour Kleinkläranlagen für bis zu 50 EW - Teil 7:
une population totale équivalente (PTE) jusqu'à 50 Vorgefertigte Anlagen für eine dritte Reinigungsstufe
habitants - Partie 7 : Unités préfabriquées de
traitement tertiaire
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 165.

If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.


EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2018 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 12566-7:2018 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------
oSIST prEN 12566-7:2018
prEN 12566-7:2018 (E)
Contents Page
European foreword . 4
3.1 Terms and definitions . 8
3.2 Symbols and abbreviated terms . 10
4.1 Design . 10
4.1.1 General. 10
4.1.2 Inlets, outlets, internal pipework and connections . 10
4.1.3 Ventilation . 11
4.1.4 Access . 11
4.1.5 Extension shaft . 11
4.1.6 Overall dimensions . 11
4.2 Load bearing capacity . 11
4.2.1 General. 11
4.2.2 Load bearing capacity determined by calculation (see 4.2.1.1, e)). . 12
4.2.3 Load bearing capacity determined by testing (see 4.2.1.1, a) to d)). . 14
4.3 Treatment efficiency . 15
4.3.1 Characteristics . 15
4.3.2 Tank selection . 16
4.4 Watertightness . 16
4.4.1 General. 16
4.4.2 Water loss . 16
4.4.3 Pressure variation . 17
4.5 Durability . 17
4.5.1 General. 17
4.5.2 Concrete . 17
4.5.3 Steel. 17
4.5.4 Unplasticized polyvinyl chloride (PVC-U) . 17
4.5.5 Polyethylene (PE) . 18
4.5.6 Glass reinforced plastic (GRP) . 19
4.5.7 Polypropylene (PP) . 19
4.5.8 Polydicyclopentadiene (PDCPD) . 20
4.5.9 Flexible sheets . 20
4.6 Reaction to fire. 20
4.6.1 General. 20
4.6.2 Classification without the need for testing . 21
4.6.3 Classification according to the test results . 21
4.7 Treatment capacity . 21
5.1 Load bearing capacity . 22
5.1.1 Crushing test . 22
5.1.2 Vertical load test . 25
5.1.3 Vacuum test . 26
5.1.4 Pit test . 27
5.2 Treatment efficiency . 29
5.2.1 General. 29
5.2.2 Installation and commissioning . 29
5.2.3 Operation and maintenance procedures during testing . 29
5.2.4 Data to be monitored . 30
5.2.5 Time for biomass establishment . 30
5.2.6 Influent characteristics . 30
2

---------------------- Page: 4 ----------------------
oSIST prEN 12566-7:2018
prEN 12566-7:2018 (E)
5.2.7 Daily flow pattern for testing . 31
5.2.8 Test procedure . 31
5.2.9 Sample analysis . 32
5.2.10 Test report . 32
5.3 Watertightness . 33
5.3.1 Water test . 33
5.3.2 Vacuum test . 34
5.4 Durability . 35
5.4.1 General . 35
5.4.2 Concrete . 35
5.4.3 Steel . 35
5.4.4 Unplasticized polyvinyl chloride (PVC-U) . 35
5.4.5 Polyethylene (PE) . 35
5.4.6 Glass reinforced plastic (GRP) . 36
5.4.7 Polypropylene (PP) . 37
5.4.8 Polydicyclopentadiene (PDCPD) . 38
5.4.9 Flexible sheets . 39
5.5 Reaction to fire . 39
6.1 General . 39
6.2 Type testing . 39
6.2.1 General . 39
6.2.2 Test samples, testing and compliance criteria . 40
6.2.3 Test reports . 46
6.2.4 Shared other party results . 46
6.2.5 Cascading determination of the product type results . 47
6.3 Factory production control . 48
6.3.1 General . 48
6.3.2 Requirements . 48
6.3.3 Product specific requirements . 51
6.3.4 Initial inspection of factory and of FPC . 51
6.3.5 Continuous surveillance of FPC . 52
6.3.6 Procedure for modifications . 52
6.3.7 One-off products, pre-production products (e.g. prototypes) and products produced
in very low quantity . 52
7.1 Marking . 53
7.2 Technical information accompanying the unit . 53
7.3 Installation instructions . 54
7.4 Operation manual . 55
Annex A (informative) Analysis method . 56
Annex B (normative) Mechanical characteristics of test samples used for load bearing
capacity calculation . 57
Annex C (normative) Alternative watertightness assessment methods for FPC (pneumatic
pressure test) . 58
Annex ZA (informative) Relationship of this European Standard with Regulation (EU)
No. 305/2011 . 59
ZA.1 Scope and relevant characteristics . 59
System of Assessment and Verification of Constancy of Performance (AVCP) . 79
Assignment of AVCP tasks . 79
Bibliography . 81
3

---------------------- Page: 5 ----------------------
oSIST prEN 12566-7:2018
prEN 12566-7:2018 (E)
European foreword
This document (prEN 12566-7:2018) has been prepared by Technical Committee CEN/TC 165 “Waste
water engineering”, the secretariat of which is held by DIN.
This document is currently submitted to the CEN Enquiry.
This document supersedes EN 12566-7:2016.
This document has been prepared under a mandate given to CEN by the European Commission and the
European Free Trade Association, and supports essential requirements for construction works of
Regulation (EU) No. 305/2011.
For relationship with Regulation (EU) No. 305/2011, see informative Annex ZA, which is an integral
part of this document.
In comparison with the previous edition, the following technical modifications have been made:
• mainly changes in AVCP clause and Annex ZA in accordance with the Construction Product
Regulation (CPR) but also changes in accordance with the CEN Rules.
The series of standards EN 12566 “Small wastewater treatment systems for up to 50 PT” contains the
following parts (see Figure 1):
• Part 1: Prefabricated septic tanks;
• Part 3: Packaged and/or site assembled domestic wastewater treatment plants;
• Part 6: Prefabricated secondary treatment unit;
• Part 7: Prefabricated tertiary treatment unit (this document);
For filtration systems, CEN/TC 165 decided to publish the following CEN Technical reports, which are
considered as Code of practices and do not specify treatment requirements:
• Part 2: Soil infiltration systems
• Part 5: Pre-treated Effluent Filtration systems
4

---------------------- Page: 6 ----------------------
oSIST prEN 12566-7:2018
prEN 12566-7:2018 (E)

Key
A domestic wastewater 1 packaged and/or site assembled septic tank
B septic tank effluent 2 soil infiltration system
C treated infiltrated effluent 3 packaged and/or site assembled domestic wastewater treatment plant
D treated wastewater 5 pre-treated effluent filtration system
E tertiary treated wastewater 6 prefabricated treatment unit used for septic tank effluent
  7 prefabricated tertiary treatment unit
Figure 1 — Scheme related to the arrangement of the parts of EN 12566
National regulations can specify different arrangements between the products described in the
standard series EN 12566.
5

---------------------- Page: 7 ----------------------
oSIST prEN 12566-7:2018
prEN 12566-7:2018 (E)
1 Scope
This document specifies characteristics and related requirements, assessment methods, the marking
and assessment and verification of constancy of performance (AVCP) procedures for prefabricated
tertiary treatment units used for populations up to 50 inhabitants.
Prefabricated tertiary treatment units in accordance with this document are:
• used for the tertiary treatment of domestic wastewater coming from:
a) products in accordance with EN 12566-3 or EN 12566-6 or;
b) installation designed and constructed in accordance with CEN/TR 12566-5.
Equivalent secondary treated effluent may come from existing systems.
• made of concrete, steel, Unplasticized Polyvinylchloride (PVC-U), Polyethylene (PE), Polypropylene
(PP), Glass Reinforced Polyester (GRP-UP), Polydicyclopentadiene (PDCPD), PVC and/or EPDM.
• used buried in the ground;
• with or without extension shaft;
• made of prefabricated components that are factory or site-assembled by one manufacturer and
which are tested as a whole.
This document does not cover prefabricated tertiary treatment units:
• where vehicle loads apply to it;
• with direct infiltration into the ground (non-watertight);
• made of retrofit kits (see definition in 3.1.9);
• forming part of products covered by EN 12566-3 and EN 12566-6;
• for microorganism reduction.
The assessment methods specified in this document establish the performance of the prefabricated
tertiary treatment unit, needed to verify its suitability for the condition in which it is normally installed.
6

---------------------- Page: 8 ----------------------
oSIST prEN 12566-7:2018
prEN 12566-7:2018 (E)
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content
constitutes requirements of this document. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any amendments) applies.
EN 206, Concrete — Specification, performance, production and conformity
EN 580, Plastics piping systems — Unplasticized poly(vinyl chloride) (PVC-U) pipes — Test method for the
resistance to dichloromethane at a specified temperature (DCMT)
EN 727, Plastics piping and ducting systems — Thermoplastics pipes and fittings — Determination of
Vicat softening temperature (VST)
EN 976-1:1997, Underground tanks of glass-reinforced plastics (GRP) - Horizontal cylindrical tanks for
the non-pressure storage of liquid petroleum based fuels - Part 1: Requirements and test methods for single
wall tanks
EN 978:1997, Underground tanks of glass-reinforced plastics (GRP) - Determination of factor alpha and
factor beta
EN 1905, Plastics piping systems - Unplasticized poly(vinyl chloride) (PVC-U) pipes, fittings and material -
Method for assessment of the PVC content based on total chlorine content
EN 1992-1-1, Eurocode 2: Design of concrete structures - Part 1-1: General rules and rules for buildings
EN 1993-1-1, Eurocode 3: Design of steel structures - Part 1-1: General rules and rules for buildings
EN 10088-1, Stainless steels - Part 1: List of stainless steels
EN 12311-2, Flexible sheets for waterproofing - Determination of tensile properties - Part 2: Plastic and
rubber sheets for roof waterproofing
EN 12566-3, Small wastewater treatment systems for up to 50 PT - Part 3: Packaged and/or site
assembled domestic wastewater treatment plants
EN 12566-6, Small wastewater treatment systems for up to 50 PT - Part 6: Prefabricated treatment units
for septic tank effluent
CEN/TR 12566-5, Small wastewater treatment systems up to 50 PT - Part 5: Pre-treated Effluent
Filtration systems
EN 13369, Common rules for precast concrete products
EN 13501-1, Fire classification of construction products and building elements — Part 1: Classification
using data from reaction to fire tests
EN 14150, Geosynthetic barriers - Determination of permeability to liquids
EN 16323:2014, Glossary of wastewater engineering terms
EN ISO 178, Plastics - Determination of flexural properties (ISO 178)
EN ISO 179 (all parts), Plastics — Determination of Charpy impact properties (ISO 179, all parts)
7

---------------------- Page: 9 ----------------------
oSIST prEN 12566-7:2018
prEN 12566-7:2018 (E)
EN ISO 527-2, Plastics - Determination of tensile properties - Part 2: Test conditions for moulding and
extrusion plastics (ISO 527-2)
EN ISO 899-2, Plastics - Determination of creep behaviour - Part 2: Flexural creep by three-point loading
(ISO 899-2)
EN ISO 1133-1:2011, Plastics - Determination of the melt mass-flow rate (MFR) and melt volume-flow rate
(MVR) of thermoplastics - Part 1: Standard method (ISO 1133-1:2011)
EN ISO 1183 (all parts), Plastics — Methods for determining the density and relative density of non-
cellular plastics (ISO 1183, all parts)
EN ISO 2505:2005, Thermoplastics pipes - Longitudinal reversion - Test method and parameters (ISO
2505:2005)
EN ISO 2555, Plastics - Resins in the liquid state or as emulsions or dispersions - Determination of
apparent viscosity using a single cylinder type rotational viscometer method (ISO 2555)
EN ISO 9967, Thermoplastics pipes - Determination of creep ratio (ISO 9967)
EN ISO 9969, Thermoplastics pipes - Determination of ring stiffness (ISO 9969)
EN ISO 13229, Thermoplastics piping systems for non-pressure applications - Unplasticized poly(vinyl
chloride) (PVC-U) pipes and fittings - Determination of the viscosity number and K-value (ISO 13229)
EN ISO 14125:1998, Fibre-reinforced plastic composites - Determination of flexural properties (ISO
14125:1998)
3 Terms, definitions, symbols and abbreviated terms
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 16323:2014 and the following
apply.
3.1.1
biological processes
processes in which the treatment is mainly carried out by micro-organism activity (i.e. sand, gravel,
peat, activated carbon, other media filtration). These processes are mostly used for the reduction of
COD, BOD, SS and nitrogen parameters
3.1.2
chemical processes
processes in which the treatment is mainly carried out by the addition of chemical agents (i.e. dosing
with ozone or with iron or aluminium derivatives for flocculation). These processes are mostly used for
the reduction of SS, phosphorus
3.1.3
electrical processes
processes in which the treatment is mainly carried out using electricity (i.e. ultraviolet, electrolysis).
These processes are mostly used for the reduction of microorganisms
8

---------------------- Page: 10 ----------------------
oSIST prEN 12566-7:2018
prEN 12566-7:2018 (E)
3.1.4
end use
condition in which a prefabricated tertiary treatment unit is normally installed
3.1.5
extension shaft
component(s) which is part of the prefabricated tertiary treatment unit, and allow access from or
slightly above the ground surface
3.1.6
flexible sheet
flexible impermeable liner
3.1.7
physical processes
processes in which the treatment is mainly carried out by using the physical properties of a media (i.e.
sand, gravel, peat, activated carbon, cartridge and drum membranes, reverse osmosis, ultra-filtration).
These processes are mostly used for the reduction of SS and phosphorus
3.1.8
product family
group of products in which, for evaluation, the selected property(s) is/are similar for all products
within the group considering at least similar shape, equipment, materials and conditions of end use and
ensures the minimum hydraulic efficiency and minimum structural behaviour for all the products in the
range
3.1.9
retrofit kit
kit installed within an existing product in accordance with EN 12566-3 or with EN 12566-6 or with
CEN/TR 12566-5
Note 1 to entry: Not covered by this standard but Where such a retrofit kit affects the declared performance of is
installed in a EN 12566-3 or EN 12566-6 unit in which it is installed, then the overall product shall be tested in full
for its conformity with the relevant standard.
3.1.10
tertiary treatment
additional treatment process which results in further purification than that obtained by applying
primary followed by a secondary treatment
Note 1 to entry: It is recommended that the expression for the treatment, e.g. nitrogen removal, phosphorus
removal, polishing effects, suspended solid removal, is used.
9

---------------------- Page: 11 ----------------------
oSIST prEN 12566-7:2018
prEN 12566-7:2018 (E)
3.2 Symbols and abbreviated terms
AVCP Assessment and Verification of Constancy
...

Questions, Comments and Discussion