Dentistry - Ceramic denture teeth (ISO 4824:1993)

Applicable to semiconductor devices (discrete devices and integrated circuits) and establishes provisions common to all the other parts of the series.
The contents of the corrigendum of August 2003 have been included in this copy.

Zahnheilkunde - Keramikzähne (ISO 4824:1993)

Diese Internationale Norm legt Anforderungen und Prüfmethoden für Keramikzähne, die für die Herstellung von herausnehmbarem Zahnersatz verwendet werden, fest.

Produits et matériel pour l'art dentaire - Dents en céramique (ISO 4824:193)

Applicable aux dispositifs à semiconducteurs (dispositifs discrets et circuits intégrés)et établit des dispositions communes à toutes les autres parties de la série.
Le contenu du corrigendum d'août 2003 a été pris en considération dans cet exemplaire.

Dentistry - Ceramic denture teeth (ISO 4824:1993)

General Information

Status
Withdrawn
Publication Date
21-May-1996
Withdrawal Date
28-Mar-2006
Technical Committee
Drafting Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
29-Mar-2006
Completion Date
29-Mar-2006

Relations

Buy Standard

Standard
EN ISO 4824:2000
English language
7 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 4824:2000
01-januar-2000
Dentistry - Ceramic denture teeth (ISO 4824:1993)
Dentistry - Ceramic denture teeth (ISO 4824:1993)
Zahnheilkunde - Keramikzähne (ISO 4824:1993)
Produits et matériel pour l'art dentaire - Dents en céramique (ISO 4824:193)
Ta slovenski standard je istoveten z: EN ISO 4824:1996
ICS:
11.060.10 =RERWHKQLþQLPDWHULDOL Dental materials
SIST EN ISO 4824:2000 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN ISO 4824:2000

---------------------- Page: 2 ----------------------

SIST EN ISO 4824:2000

---------------------- Page: 3 ----------------------

SIST EN ISO 4824:2000

---------------------- Page: 4 ----------------------

SIST EN ISO 4824:2000

---------------------- Page: 5 ----------------------

SIST EN ISO 4824:2000

---------------------- Page: 6 ----------------------

SIST EN ISO 4824:2000
INTERNATIONAL
STANDARD
Second edition
1993-02-01
Dentistry
- Ceramic denture teeth
Produits et materiel pour I’art dentaire - Dents en ckamique
Y -
Reference number
IS0 4824:1993(E)
- -

---------------------- Page: 7 ----------------------

SIST EN ISO 4824:2000
IS0 4824:1993(E)
Foreword
IS0 (the International Organization for Standardization) is a worldwide
federation of national standards bodies (IS0 member bodies). The work
of preparing International Standards is normally carried out through IS0
technical committees. Each member body interested in a subject for
which a technical committee has been established has the right to be
represented on that committee. International organizations, governmental
and non-governmental, in liaison with ISO, also take part in the work. IS0
collaborates clos’ely with the International Electrotechnical Commission
(IEC) on all matters of electrotechnical standardization.
Draft International Standards adopted by the technical committees are
circulated to the member bodies for voting. Publication as an International
Standard requires approval by at least 75 % of the member bodies casting
a vote.
International Standard IS0 4824 was prepared by Technical Committee
lSO/rC 106, Dentistry, Sub-Committee SC 2, Prosthodontic materiak.
This second edition cancels and replaces the first edition (IS0 4824:1981)
of which it constitutes a technical revision, differing in the following re-
spects.
a) The title has been modified to include other ceramics in addition to
porcelain.
b) A statement concerning the addition of fluorescing agents has been
added.
0 IS0 1993
All rights reserved. No part of this publication may be reproduced or utilized in any form or
by any means, electronic or mechanical, including photocopying and microfilm, without per-
mission in writing from the publisher.
International Organization for Standardization
Case Postale 56 l CH-1211 Geneve 20 l Switzerland
Printed in Switzerland

---------------------- Page: 8 ----------------------

SIST EN ISO 4824:2000
IS0 4824:1993(E)
Introduction
Specific qualitative and quantitative requirements of freedom from bio-
logical hazard are not included in this International Standard but it is rec-
ommended that, in assessing possible biological or toxicological hazards,
reference should be made to ISO/rR 7405:1984, Biological evaluation of
dental materiak, or any more recent edition.
. . .
III

---------------------- Page: 9 ----------------------

SIST EN ISO 4824:2000
This page intentionally left blank

---------------------- Page: 10 ----------------------

SIST EN ISO 4824:2000
IS0 4824:1993(E)
INTERNATIONAL STANDARD
Dentistry - Ceramic denture teeth
3.5 set: Set of six anterior pin teeth or eight
1 Scope
posterior diatoric teeth, as received from the manu-
facturer.
This International Standard specifies the requirements
and test methods for ceramic teeth suitable for use
3.6 half-set: Three teeth on one side of a set of
in the manufacture of removable prostheses.
anterior teeth or four teeth on one side of a set of
posterior teeth.
2 Normative references
The following standards contain provisions which,
4 Requirements
through reference in this text, constitute provisions
of this International Standard. At the time of publi-
cation, the editions indicated were valid. All standards
4.1 Material
are subject to revision, and parties to agreements
based on this International Standard are encouraged
Substances which will increase the radioactivity of the
to investigate the possibility of applying the most re-
ceramic shall not be added.
cent editions of the standards indicated below.
Members of IEC and IS0 maintain registers of cur-
rently valid International Standards.
4.2 Dimensions of teeth
IS0 1567:1988, Dentistry - Denture base polymers.
The dimensions of the teeth when examined in ac-
with 6.2 shall not differ by more than 7 %
cordance
IS0 1942-l :1989, Dental vocabulary - Part I: Gen-
values shown in the manufacturer’s mould
from the
eral and clinical terms.
chart.
IS0 6873:1983, Dental gypsum products.
lour and blending of shades
3 Definitions
Anterior teeth shall be a blend of two or more colours.
Anterior teeth, and posterior teeth if blended, shall
For the purposes of this International Standard, the
show no line of demarcation between incisal and
following definitions apply.
cervical portions on the facial aspects of the teeth.
This requirement is not intended to disallow especially
3.1 anterior teeth (type I): Teeth of forms approxi-
designed demarcations placed to simulate filling bor-
/
mating those of human anterior teeth. (See
I
ders or enamel imperfections found in natural teeth.
I
IS0 1942-I :1989, definition 1.043.)
I
I
\ The shape, colour, visual appearance and blending of
I
I the teeth in all the sets of the sample (see clause 5)
3.2 diatoric teeth: Teeth designed to be retained
shall correspond to the manufacturer’s shade guide
by anchorage slots and/or holes.
I
when inspected visually against the same background
I
I
in accordance with 6.1.
3.3 pin teeth: Teeth designed to be retained by
headed pins.
4.4 Biocompatibility
3.4 posterior teeth (type II): Teeth approximating
j
the form or function of human posterior teeth. (See
1
See the Introduction for guidance on biocompatibility.
IS0 1942-l :1989, definiton 1.044.)
,
1

---------------------- Page: 11 ----------------------

SIST EN ISO 4824:2000
IS0 4824:1993(E)
for conformity to the mould chart dimensions (4.2).
4.5 Surface finish
Measure the maximum me&o-distal and cervico-
incisal dimensions of the upper and lower left central
When inspected visually, the teeth as received (ex-
incisors (21, 31) and the overall facie-lingual dimen-
cluding retention areas) shall have a smooth, lustrous,
sions of the crowns of the upper and lower left first
non-porous surface.
molars (26, 36) using a micrometer (6.2.1 .I).
When the teeth are tested in accordance with 6.3, the
original finish of the teeth shall not have been im-
paired by the processing, and the teeth shall be ca- 6.3 Surface finish
pable of being ground and polished.
6.3.1 Apparatus
4.6 Anchorage of diatoric teeth
6.3.1.1 Wet, 300 grit silicon carbide lathe wheel,
All diatoric teeth, examined in accordance with 6.4,
of diameter 63mm+3mm and thickness
shall provide a means of positive retention and have
4,7 mm + 0,3 mm, capable of being rotated at
holes all of which shall be patent.
1 700 r/r& + 300 r/min.
4.7 Resistance to thermal shock
6.3.1.2 Equipment for polishing dental ceramic.
The tee
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.