Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 011: Nickel plated copper - Operating temperatures, between - 65 °C and 150 °C - Dual extruded wall for open applications, with jacket without screen - UV laser printable - Product standard

This standard specifies the characteristics of UV laser printable jacket, nickel plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer  XLETFE family for use in the on-board electrical systems of aircraft at operating temperatures between - 65 °C and 150 °C, operating at voltages not exceeding 600 V r.m.s and frequencies not exceeding 2 000 Hz. These cables are suitable for airframe use without additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.

Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen zur allgemeinen Verwendung - XLETFE-Familie - ummantelt oder geschirmt und ummantelt - Teil 011: Kupfer vernickelt - Betriebstemperaturen zwischen 65 °C und 150 °C, doppelt extrudierte Isolierung für offene Anwendungen, ummantelt ohne Schirm - UV-Laser bedruckbar - Produktnorm

Diese Europäische Norm legt die Eigenschaften von elektrischen Leitungen aus der XLETFE-Familie (quervernetztes
Ethylen-Tetrafluorethylen-Co-Polymer) mit UV-Laser bedruckbarem Mantel und vernickeltem Kupferleiter
zur Verwendung in elektrischen Bordnetzen von Luftfahrzeugen bei Betriebstemperaturen zwischen
65 °C und 150 °C, Betriebsspannungen mit einem Effektivwert bis 600 V und Frequenzen von maximal
2 000 Hz fest. Diese Leitungen sind für die Verlegung in Luftfahrzeugzellen ohne Zusatzschutz geeignet. Bei
Widersprüchen zwischen dieser Norm und anderen zitierten Dokumenten gelten die Anforderungen dieser
Norm.

Série aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Gainés ou blindés et gainés - Partie 011: Cuivre nickelé - Températures de fonctionnement comprises entre – 65 °C et 150 °C - Fil double isolé pour applications externes, gainé non blindé - Marquable au laser UV - Norme de produit

Aeronavtika - Kabli, električni, za splošne namene, eno- in večžilni - Družina XLETFE - Oplaščeni ali zaslonjeni in oplaščeni - 011. del: Ponikljani baker - Obratovalne temperature med -65 °C in 135 °C - Dvojno ekstrudirana izolacija za zunanjo uporabo, s plaščem brez zaslona - Potiskljiva z UV-laserjem - Standard za izdelek

Ta standard določa lastnosti plašča, potiskljivega z UV-laserjem, vodnika iz ponikljanega bakra in električnih kablov iz družine kopolimerov, pridobljenih z mrežno polimerizacijo etilena in tetrafluoretilena XLETFE, za uporabo v električnih sistemih na krovu letal pri obratovalnih temperaturah med –65 °C in 150 °C, obratovalnih napetostih, ki ne presegajo efektivne vrednosti 600 V, ter frekvencah, ki ne presegajo 2000 Hz. Ti kabli so primerni za uporabo na ogrodjih letal brez dodatne zaščite. V primeru neskladja med tem standardom in drugimi navedenimi dokumenti imajo prednost določila tega standarda.

General Information

Status
Withdrawn
Publication Date
18-Oct-2011
Withdrawal Date
27-Aug-2019
Technical Committee
Drafting Committee
Current Stage
9960 - Withdrawal effective - Withdrawal
Completion Date
28-Aug-2019

Relations

Buy Standard

Standard
EN 4612-011:2012
English language
9 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.L]GHOHNLuft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen für allgemeine Verwendung - XLETFE Familie - Mit Mantel oder geschirmt und Mantel - Teil 011: Kupfer vernickelt - Betriebstemperaturen zwischen – 65 °C und 150 °C - Doppelt extrudierte Isolierung für externe Verwendung, mit Mantel ohne Schirm - UV-Laser bedruckbar - ProduktnormSérie aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Gainés ou blindés et gainés - Partie 011: Cuivre nickelé - Températures de fonctionnement comprises entre – 65 °C et 150 °C - Fil double isolé pour applications externes, gainé non blindé - Marquable au laser UV - Norme de produitAerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 011: Nickel plated copper - Operating temperatures, between - 65 °C and 150 °C - Dual extruded wall for open applications, with jacket without screen - UV laser printable - Product standard49.060Aerospace electric equipment and systemsICS:Ta slovenski standard je istoveten z:EN 4612-011:2011SIST EN 4612-011:2012en,fr01-februar-2012SIST EN 4612-011:2012SLOVENSKI
STANDARD



SIST EN 4612-011:2012



EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 4612-011
October 2011 ICS 49.060 English Version
Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 011: Nickel plated copper - Operating temperatures, between - 65 °C and 150 °C - Dual extruded wall for open applications, with jacket without screen - UV laser printable - Product standard
Série aérospatiale - Câbles, électriques, d'usage général, mono et multiconducteurs - Famille XLETFE - Gainés ou blindés et gainés - Partie 011: Cuivre nickelé - Températures de fonctionnement comprises entre - 65 °C et 150 °C - Fil double isolé pour applications externes, gainé non blindé - Marquable au laser UV - Norme de produit
Luft- und Raumfahrt - Ein- und mehradrige elektrische Leitungen für allgemeine Verwendung - XLETFE Familie - Mit Mantel oder geschirmt und Mantel - Teil 011: Kupfer vernickelt - Betriebstemperaturen zwischen -65 °C und 150 °C - Doppelt extrudierte Isolierung für externe Verwendung, mit Mantel ohne Schirm - UV-Laser bedruckbar - Produktnorm This European Standard was approved by CEN on 20 August 2011.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre:
Avenue Marnix 17,
B-1000 Brussels © 2011 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 4612-011:2011: ESIST EN 4612-011:2012



EN 4612-011:2011 (E) 2 Contents Page Foreword .31Scope .42Normative references .43Terms, definitions and symbols .44Materials and construction .45Required characteristics .56Quality assurance .87Designation .
...