EN 61300-2-8:1997
(Main)Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-8: Tests - Bump
- BACK
- 09-Jul-1997
- 31-May-1998
- 33.180.20
- CLC/TC 86BXA
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-8: Tests - Bump
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prüf- und Meßverfahren - Teil 2-8: Prüfungen - Vielfachschock
Dispositifs d'interconnexion et composants passifs à fibres optiques - Méthodes fondamentales d'essais et de mesures - Partie 2-8: Essais - Secousses
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-8: Tests – Bump (IEC 61300-2-8:1995)
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 61300-2-8:1999
01-maj-1999
Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures - Part 2-8: Tests – Bump (IEC 61300-2-8:1995)
Fibre optic interconnecting devices and passive components - Basic test and
measurement procedures -- Part 2-8: Tests - Bump
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Grundlegende Prüf- und
Meßverfahren -- Teil 2-8: Prüfungen - Vielfachschock
Dispositifs
...
This May Also Interest You
IEC 61300-2-44:2024 specifies a test to determine the influence of flexing under tensile load of the strain relief of fibre optic interconnecting devices or components. The intention is to simulate the number of flexing cycles which would typically be experienced during service life. This test is applied to both single fibre cable and multiple fibre cable. This fourth edition cancels and replaces the third edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) replaced active monitoring with transient loss for measurements during test; b) harmonized recommended severities according to IEC 61753-1.
- Draft9 pagesEnglish languagesale 10% offe-Library read for×1 day
- 04-Apr-2024
- 33.180.20
- CLC/TC 86BXA
IEC 61300-2-6:2023 is available as IEC 61300-2-6:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61300-2-6:2023 describes a test to ensure the coupling mechanism of a connector set or connector and device combination withstands the axial loads likely to be applied during normal service, and that the optical performance remains within the given specifications during this test. This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of normative references; b) modification of the details to be specified; c) addition of optical monitoring.
- Standard13 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Jan-2024
- 33.180.20
- CLC/TC 86BXA
IEC 61300-2-11:2023 is available as IEC 61300-2-11:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61300-2-11:2023 is to ensure that the captivation or the attachment of the cable to the fibre optic devices or components, for example fibre optic closures, will withstand compressive axial loads likely to be applied during normal service. This third edition cancels and replaces the second edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) added Terms and definitions clause; b) removed severity table for closures; c) added recommended severity for tubes and cables without strength member attachment.
- Standard12 pagesEnglish languagesale 10% offe-Library read for×1 day
- 11-Jan-2024
- 33.180.20
- CLC/TC 86BXA
IEC 61753-021-02:2023 defines the minimum initial test and measurement requirements and severities which single-mode fibre optic connectors terminated as a pigtail or a patchcord satisfy in order to be categorized as meeting the IEC standard category C (controlled environment), as defined in IEC 61753-1. If tests were performed on the connectors terminated as pigtails or patchcords for categories OP+HD, OP+, OP, OPHD, or CHD and the product passed, the product will be automatically qualified or categorized as meeting the IEC standard for category C. This first edition cancels and replaces the second edition of IEC 61753-021-2 published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 61753-021-2:2007: a) changed scope to remove restrictions on attenuation and return loss grades; b) included provisions for rectangular ferrule connectors; c) changed the terms and definitions of the different types of test samples (pigtail test samples and patchcord test samples) used in the various tests to avoid confusion; d) updated fibre naming conventions according to IEC 60793-2-50 and added provisions for B-657 fibres; e) added all the attenuation and return loss grades defined in IEC 61753-1; f) test severities updated according to IEC 61753-1; g) reduced flexing of strain relief cycles from 100 cycles to 50 cycles; h) added the torsion test; i) reduced the duration of the fibre/cable retention test on reinforced cables from 120 s to 60 s minimum; j) removed the static side load test; k) reduced the number of mating durability cycles from 500 cycles to 200 cycles and added provisions for rectangular ferrule connectors; l) added Annex B for visual examination of the outer cable sheath movement of reinforced cables as an additional requirement for change of temperature, cable retention and flexing of the strain relief tests.
- Standard24 pagesEnglish languagesale 10% offe-Library read for×1 day
- 16-Nov-2023
- 33.180.20
- CLC/TC 86BXA
IEC 61753-021-06:2023 defines the minimum initial test and measurement requirements and severities which single-mode fibre optic connectors terminated as a pigtail or a patchcord satisfy in order to be categorised as meeting the IEC standard category OP+ (extended outdoor protected environment), as defined in IEC 61753-1. If tests were performed on the connectors terminated as pigtails or patchcords for category OP+HD and the product passed, the product will be automatically qualified or categorized as meeting the IEC standard for category OP+. If tests are performed on the connectors terminated as pigtails or patchcords for category OP+, and the product passes, the product will be automatically qualified or categorized as meeting the IEC standard for categories OP and C. This first edition cancels and replaces the first edition of IEC 61753-021-6 published in 2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 61753-021-6:2007: a) updated environmental category (from O to OP+), tests and their severities according to IEC 61753-1:2018; b) removed the copyright notice as it is no longer needed; c) changed title and scope to remove restrictions on attenuation and return loss grades; d) changed the term and definitions of the different types of test samples (pigtail test samples and patchcord test samples) used in the various tests to avoid confusion; e) removed the term and definition for small form factor (SFF) connectors as it is no longer used in the document; f) updated fibre naming conventions according to IEC 60793-2-50: and added provisions for B-657 fibres; g) added all the attenuation and return loss grades defined in IEC 61753-1; h) removed the static side load test; i) removed the need to perform all tests sequentially to align with other performance standards; j) added provisions for rectangular ferrule connectors; k) added Annex B for visual examination of the outer cable sheath movement of reinforced cables as an additional requirement for change of temperature, cable retention and flexing of the strain relief tests.
- Standard27 pagesEnglish languagesale 10% offe-Library read for×1 day
- 16-Nov-2023
- 33.180.20
- CLC/TC 86BXA
IEC 61300-2-38:2023 is available as IEC 61300-2-38:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61300-3-38:2023 presents two methods for testing the sealing performance of a fibre optic sealed closure and hardened connector using air pressure. This third edition cancels and replaces the second edition published in 2006. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of sealed hardened connectors; b) recommended test severities from IEC 61753-1; c) test configurations for hardened connectors and adaptors.
- Standard16 pagesEnglish languagesale 10% offe-Library read for×1 day
- 14-Sep-2023
- 33.180.20
- CLC/TC 86BXA
IEC 61300-2-26: 2023 provides a test to determine the corrosion resistance of the metals used in the construction of fibre optic interconnecting devices and passive components. This document determines if dissimilar metals have been well finished to prevent corrosion. The requirements of the tests for these devices are defined in IEC 61753-1. This third edition cancels and replaces the second edition published in 2006. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of Clause 3, Terms and definitions; b) harmonisation with IEC 61753-1:2018 and addition of Table 2; c) harmonisation with IEC 60068-2-11:2021
- Standard15 pagesEnglish languagesale 10% offe-Library read for×1 day
- 31-Aug-2023
- 33.180.20
- CLC/TC 86BXA
IEC 61300-3-45:2023 is available as IEC 61300-3-45:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61000-3-45:2023 describes the procedure required to measure the statistical distribution and mean attenuation for random mated optical connectors with physical contact (PC) and angled physical contact (APC) polished multi-fibre rectangular ferrules as defined in the IEC 61754 series. This measurement method is applicable to cable assemblies. This second edition cancels and replaces the first edition published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of sample size for > 12-fibre connector measurement; b) inclusion of guidance for multimode measurement.
- Standard20 pagesEnglish languagesale 10% offe-Library read for×1 day
- 24-Aug-2023
- 33.180.20
- CLC/TC 86BXA
1.1 Product definition This document contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements, which single mode mechanical splice needs to meet in order for it to be categorized as a European standard product. Although, in this document, the product is qualified for EN IEC 60793 2 50 type B-652.D single mode fibres, it is also suitable for mechanical splicing of other single mode fibres with 125 µm diameter glass cladding. Also mechanical splices designed for connections of buffered or secondary coated fibres and cords according to EN 60794 2 50:2008 are covered by this document. 1.2 Interoperability The installed mechanical splice fits into optical fibre management system with optical splice cassettes or splice trays as defined in EN IEC 61756 1. This document specifies the following two physical interface dimensions: - cross sectional profile with width, height or diameter (in millimetres); - length (in millimetres). 1.3 Expected performance In this document, the performance of the mechanical splice is given with identical fibres only as specified in Annex A. Losses associated with tolerances in fibre cladding diameter and mode field mismatch are not taken into account. The measured attenuation is a function of the core concentricity, cladding non-circularity and alignment capability. The optical return loss performance is a function of the index matching gel and the fibre end face preparation. 1.4 Operating environment The tests selected combined with the severities and durations are representative of an outdoor enclosed environment defined as category OP in EN IEC 61753 1. To ensure that the product can be used in outdoor closures, boxes or street cabinets for categories A, G or S (as defined in EN IEC 61753 1) the specified lower temperature is extended to −40 °C and a water immersion requirement for temporary flooding conditions has been added. 1.5 Reliability Whilst the anticipated service life expectancy of the product in this environment is at least 20 years, compliance with this document does not guarantee the reliability of the product. This is expected to be predicted using a recognized reliability assessment programme. 1.6 Quality assurance Compliance with this document does not guarantee the manufacturing consistency of the product. This is expected to be maintained using a recognized quality assurance programme.
- Standard21 pagesEnglish languagesale 10% offe-Library read for×1 day
- 20-Jul-2023
- 33.180.20
- CLC/TC 86BXA
- Corrigendum3 pagesEnglish languagesale 10% offe-Library read for×1 day
- 13-Jul-2023
- 33.180.20
- CLC/TC 86BXA
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.