Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 7-3: Type MPO connector family - Two fibre rows 16 fibre wide

This part of IEC 61754 defines the standard interface dimensions for type MPO family of connectors with two rows of 16 fibres.

Lichtwellenleiter - Verbindungselemente und passive Bauteile - Steckgesichter von Lichtwellenleiter-Steckverbindern - Teil 7-3: Steckverbinderfamilie der Bauart MPO - Zwei Faserreihen mit jeweils 16 Fasern

Dispositifs d'interconnexion et composants passifs àfibres optiques - Interfaces de connecteurs à fibres optiques - Partie 7-3: Famille de connecteurs de type MPO - Deux rangées de 16 fibres

La présente partie de l'IEC 61754 définit les dimensions d’interface normalisées pour la famille de connecteurs de type MPO comportant deux rangées de 16 fibres.

Optični spojni elementi in pasivne komponente - Vmesniki optičnih konektorjev - 7-3. del: Skupina konektorjev vrste MPO - Dvoredni s po 16 vlaken (IEC 61754-7-3:2019)

Ta del standarda IEC 61754 opredeljuje standardne mere vmesnikov za družino konektorjev vrste MPO z dvema redoma 16 vlaken.

General Information

Status
Published
Publication Date
23-May-2019
Withdrawal Date
09-May-2022
Current Stage
6060 - Document made available - Publishing
Start Date
24-May-2019
Completion Date
24-May-2019

Buy Standard

Standard
EN IEC 61754-7-3:2019
English language
28 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-oktober-2019
Optični spojni elementi in pasivne komponente - Vmesniki optičnih konektorjev - 7
-3. del: Skupina konektorjev vrste MPO - Dvoredni s po 16 vlaken (IEC 61754-7-
3:2019)
Fibre optic interconnecting devices and passive components - Fibre optic connector
interfaces - Part 7-3: Type MPO connector family - Two fibre rows 16 fibre wide (IEC
61754-7-3:2019)
Lichtwellenleiter - Verbindungselemente und passive Bauteile - Steckgesichter von
Lichtwellenleiter-Steckverbindern - Teil 7-3: Steckverbinderfamilie der Bauart MPO -
Zwei Faserreihen mit jeweils 16 Fasern (IEC 61754-7-3:2019)
Dispositifs d'interconnexion et composants passifs àfibres optiques - Interfaces de
connecteurs à fibres optiques - Partie 7-3: Famille de connecteurs de type MPO - Deux
rangées de 16 fibres (IEC 61754-7-3:2019)
Ta slovenski standard je istoveten z: EN IEC 61754-7-3:2019
ICS:
33.180.20 Povezovalne naprave za Fibre optic interconnecting
optična vlakna devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN IEC 61754-7-3

NORME EUROPÉENNE
EUROPÄISCHE NORM
May 2019
ICS 33.180.20
English Version
Fibre optic interconnecting devices and passive components -
Fibre optic connector interfaces - Part 7-3: Type MPO connector
family - Two fibre rows 16 fibre wide
(IEC 61754-7-3:2019)
Dispositifs d'interconnexion et composants passifs àfibres Lichtwellenleiter - Verbindungselemente und passive
optiques - Interfaces de connecteurs à fibres optiques - Bauteile - Steckgesichter von Lichtwellenleiter-
Partie 7-3: Famille de connecteurs de type MPO - Deux Steckverbindern - Teil 7-3: Steckverbinderfamilie der Bauart
rangées de 16 fibres MPO - Zwei Faserreihen mit jeweils 16 Fasern
(IEC 61754-7-3:2019) (IEC 61754-7-3:2019)
This European Standard was approved by CENELEC on 2019-05-10. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden,
Switzerland, Turkey and the United Kingdom.

European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2019 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN IEC 61754-7-3:2019 E

European foreword
The text of document 86B/4176/FDIS, future edition 1 of IEC 61754-7-3, prepared by SC 86B "Fibre
optic interconnecting devices and passive components" of IEC/TC 86 "Fibre optics" was submitted to
the IEC-CENELEC parallel vote and approved by CENELEC as EN IEC 61754-7-3:2019.
The following dates are fixed:
• latest date by which the document has to be implemented at national (dop) 2020-02-10
level by publication of an identical national standard or by endorsement
• latest date by which the national standards conflicting with the (dow) 2022-05-10
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC shall not be held responsible for identifying any or all such patent rights.

Endorsement notice
The text of the International Standard IEC 61754-7-3:2019 was approved by CENELEC as a
European Standard without any modification.

IEC 61754-7-3 ®
Edition 1.0 2019-04
INTERNATIONAL
STANDARD
NORME
INTERNATIONALE
Fibre optic interconnecting devices and passive components – Fibre optic

connector interfaces –
Part 7-3: Type MPO connector family –Two fibre rows 16 fibre wide

Dispositifs d'interconnexion et composants passifs àfibres optiques – Interfaces

de connecteurs à fibres optiques –

Partie 7-3: Famille de connecteurs de type MPO – Deux rangées de 16 fibres

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE
ICS 33.180.20 ISBN 978-2-8322-6714-1

– 2 – IEC 61754-7-3:2019 © IEC 2019
CONTENTS
FOREWORD . 3
INTRODUCTION . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 Description . 6
5 Interfaces . 7

Figure 1 – MPO connector configurations . 7
Figure 2 – Optical datum target location diagrams . 8
Figure 3 – Gauge pin . 8
Figure 4 – Gauge for plug . 9
Figure 5 – MPO female plug, down-angled interface . 10
Figure 6 – MPO female plug, up-angled interface . 10
Figure 7 – MPO male plug, down-angled interface . 12
Figure 8 – MPO male plug, up-angled interface . 13
Figure 9 – MPO female plug, flat interface . 15
Figure 10 – MPO male plug, flat interface . 17
Figure 11 – MPO adaptor interface, opposed keyway configuration . 19
Figure 12 – MPO adaptor interface, aligned keyway configuration . 21
Figure 13 – MPO active device receptacle, angled interface . 23
Figure 14 – MPO active device receptacle, flat interface . 25

Table 1 – Intermateability between plugs and adaptors/housings/receptacles . 7
Table 2 – Dimensions of the gauge pin . 8
Table 3 – Dimensionsof the gauge for plug . 9
Table 4 – Dimensions of the MPO female plug, down- or up-angled interface . 11
Table 5 – Dimensions of the MPO male plug, down- or up-angled interface . 13
Table 6 – Dimensions of the MPO female plug, flat interface . 16
Table 7 – Dimensions of the MPO male plug, flat interface . 18
Table 8 – Dimensions of the MPO adaptor interface, opposed keyway configuration . 20
Table 9 – Dimensions of the MPO adaptor interface, aligned keyway configuration . 22
Table 10 – Dimensions of the MPO active device receptacle, angled interface . 24
Table 11 – Dimensions of the MPO active device receptacle, flat interface . 26

IEC 61754-7-3:2019 © IEC 2019 – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIBRE OPTIC INTERCONNECTING
DEVICES AND PASSIVE COMPONENTS –
FIBRE OPTIC CONNECTOR INTERFACES –

Part 7-3: Type MPO connector family –
Two fibre rows 16 fibre wide
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and
in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports,
Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their
preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
may participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
Standardization (ISO) in accordance with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence between
any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent
rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61754-7-3 has been prepared by subcommittee 86B: Fibre optic
interconnecting devices and passive components, of IEC technical committee 86: Fibre optics.
The text of this International Standard is based on the following documents:
FDIS Report on voting
86B/4176/FDIS 86B/4190/RVD
Full information on the voting for the approval of this International Standard can be found in the
report on voting indicated in the above table.
This document has been drafted in accordance with the ISO/IEC Directives, Part 2.

– 4 – IEC 61754-7-3:2019 © IEC 2019
A list of all parts in the IEC 61754 series, published under the general title Fibre optic
interconnecting devices and passive components – Fibre optic connector interfaces, can be
found on the IEC website.
The committee has decided that the contents of this document will remain unchanged until the
stability date indicated on the IEC website under "http://webstore.iec.ch" in the data related to
the specific document. At this date, the document will be
• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
IEC 61754-7-3:2019 © IEC 2019 – 5 –
INTRODUCTION
The International Electrotechnical Commission (IEC) draws attention to the fact that it is claimed
that compliance with this document may involve the use of patents concerning MPO connectors.
The IEC takes no position concerning the evidence, validity and sc
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.