Optical fibres - Part 1-46: Measurement methods and test procedures - Monitoring of changes in attenuation

Lichtwellenleiter – Teil 1-46: Messmethoden und Prüfverfahren - Überwachung von Änderungen der optischen Dämpfung

Fibres optiques — partie 1-46: Méthodes de mesure et procédures d’essai — contrôle des variations de l’affaiblissement

Optična vlakna - 1-46. del: Merilne metode in postopki preskušanja - Nadzorovanje sprememb slabljenja

General Information

Status
Not Published
Publication Date
28-Jul-2024
Current Stage
5060 - Voting results sent to TC, SR - Formal Approval
Start Date
26-Apr-2024
Completion Date
26-Apr-2024

Relations

Buy Standard

Draft
prEN IEC 60793-1-46:2023
English language
12 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
oSIST prEN IEC 60793-1-46:2023
01-oktober-2023
Optična vlakna - 1-46. del: Merilne metode in postopki preskušanja - Nadzorovanje
sprememb slabljenja
Optical fibres - Part 1-46: Measurement methods and test procedures - Monitoring of
changes in attenuation
Fibres optiques - Partie 1-46: Méthodes de mesure et procédures d'essai - Contrôle des
variations du facteur de transmission optique
Ta slovenski standard je istoveten z: prEN IEC 60793-1-46:2023
ICS:
33.180.10 (Optična) vlakna in kabli Fibres and cables
oSIST prEN IEC 60793-1-46:2023 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
oSIST prEN IEC 60793-1-46:2023

---------------------- Page: 2 ----------------------
oSIST prEN IEC 60793-1-46:2023
86A/2334/CDV
COMMITTEE DRAFT FOR VOTE (CDV)

PROJECT NUMBER:
IEC 60793-1-46 ED2
DATE OF CIRCULATION: CLOSING DATE FOR VOTING:
2023-08-04 2023-10-27
SUPERSEDES DOCUMENTS:
86A/2303/CD, 86A/2329A/CC

IEC SC 86A : FIBRES AND CABLES
SECRETARIAT: SECRETARY:
France Mr Laurent Gasca
OF INTEREST TO THE FOLLOWING COMMITTEES: PROPOSED HORIZONTAL STANDARD:


Other TC/SCs are requested to indicate their interest, if
any, in this CDV to the secretary.
FUNCTIONS CONCERNED:
EMC ENVIRONMENT QUALITY ASSURANCE SAFETY
SUBMITTED FOR CENELEC PARALLEL VOTING NOT SUBMITTED FOR CENELEC PARALLEL VOTING
Attention IEC-CENELEC parallel voting
The attention of IEC National Committees, members of
CENELEC, is drawn to the fact that this Committee Draft
for Vote (CDV) is submitted for parallel voting.
The CENELEC members are invited to vote through the
CENELEC online voting system.

This document is still under study and subject to change. It should not be used for reference purposes.
Recipients of this document are invited to submit, with their comments, notification of any relevant patent rights of
which they are aware and to provide supporting documentation.
Recipients of this document are invited to submit, with their comments, notification of any relevant “In So me
Countries” clauses to be included should this proposal proceed. Recipients are reminded that the CDV stage is
the final stage for submitting ISC clauses. (SEE AC/22/2007 OR NEW GUIDANCE DOC).

TITLE:
Optical fibres - Part 1-46: Measurement methods and test procedures - Monitoring of changes
in attenuation

PROPOSED STABILITY DATE: 2028

NOTE FROM TC/SC OFFICERS:


Copyright © 2023 International Electrotechnical Commission, IEC. All rights reserved. It is permitted to
download this electronic file, to make a copy and to print out the content for the sole purpose of preparing National
Committee positions. You may not copy or "mirror" the file or printed version of the document, or any part of it,
for any other purpose without permission in writing from IEC.

---------------------- Page: 3 ----------------------
oSIST prEN IEC 60793-1-46:2023
IEC CDV 60793-1-46/Ed2 © IEC:2023 – 2 – 86A/2334/CDV
1 CONTENTS
2 FOREWORD . 3
3 INTRODUCTION . 5
4 1 Scope . 6
5 2 Normative references . 6
6 3 Terms and definitions . 6
7 4 Reference test method . 7
8 5 Apparatus . 7
9 6 Sampling and specimens . 7
10 6.1 Specimen length . 7
11 6.2 Specimen end face . 7
12 6.3 Specimen preparation . 7
13 6.4 Reference specimen . 7
14 7 Procedure . 7
15 8 Calculations. 7
16 9 Results .
...