33.180.10 - Fibres and cables
Fibres and cables
Glasfasern. Glasfaserkabel
Fibres et cables
(Optična) vlakna in kabli
General Information
This standard specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions.
- Amendment4 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment4 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 60794-6-20:2020 is a family specification covering optical fibre outdoor cables which are flame retardant and thus also applicable to indoor environments. These cables generally possess the characteristics associated with outdoor cable designs having similar thermal and mechanical robustness that makes them suitable for use in the outside plant, while simultaneously exhibiting the fire performance required in indoor premises. A typical application is for example the extension of a "shorter l...view more
- Standard24 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 60794-6:2020 is a sectional specification covering general features of optical fibre cables applicable to outdoor as well as indoor environments, called "indoor-outdoor cables". Indoor-outdoor cables are deployed in outside plant environments as well as in premises thus fulfilling outdoor as well as indoor requirements. Typical application spaces are, for example, extension of a duct cable into a building or using this design for centralized cabling in the central office, the premises or loc...view more
- Standard13 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 60794-6-10:2020 is a family specification covering features of optical fibre cables applicable to outdoor as well as indoor environments, called "universal indoor-outdoor cables". These cables generally possess the characteristics associated with outdoor cable designs (according to IEC 60794-3, however typically less stringent, and typically "non armoured") having the thermal and mechanical robustness that makes them suitable for use in the outside plant, while simultaneously being flexible ...view more
- Standard26 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 60794-6-30:2020 is a family specification covering optical fibre indoor cables that are deployed in short length (≤ 10 m) outdoor environments. These cables generally possess the characteristics associated with indoor cable designs having the appropriate fire performance and flexibility that makes them suitable for use in premises. Because of its predicted use outdoors, stability against environmental attack, for example UV radiation and humidity (see IEC 60794-6:2020, Table 1), is important...view more
- Standard27 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 60794-6-20:2020 is a family specification covering optical fibre outdoor cables which are flame retardant and thus also applicable to indoor environments. These cables generally possess the characteristics associated with outdoor cable designs having similar thermal and mechanical robustness that makes them suitable for use in the outside plant, while simultaneously exhibiting the fire performance required in indoor premises. A typical application is for example the extension of a "shorter l...view more
- Standard42 pagesEnglish and French language
sale 15% off
IEC 60794-6-10:2020 is a family specification covering features of optical fibre cables applicable to outdoor as well as indoor environments, called "universal indoor-outdoor cables". These cables generally possess the characteristics associated with outdoor cable designs (according to IEC 60794-3, however typically less stringent, and typically "non armoured") having the thermal and mechanical robustness that makes them suitable for use in the outside plant, while simultaneously being flexible ...view more
- Standard43 pagesEnglish and French language
sale 15% off
IEC 60794-6:2020 is a sectional specification covering general features of optical fibre cables applicable to outdoor as well as indoor environments, called "indoor-outdoor cables". Indoor-outdoor cables are deployed in outside plant environments as well as in premises thus fulfilling outdoor as well as indoor requirements. Typical application spaces are, for example, extension of a duct cable into a building or using this design for centralized cabling in the central office, the premises or loc...view more
- Standard20 pagesEnglish and French language
sale 15% off
IEC 60794-6-30:2020 is a family specification covering optical fibre indoor cables that are deployed in short length (≤ 10 m) outdoor environments. These cables generally possess the characteristics associated with indoor cable designs having the appropriate fire performance and flexibility that makes them suitable for use in premises. Because of its predicted use outdoors, stability against environmental attack, for example UV radiation and humidity (see IEC 60794-6:2020, Table 1), is important...view more
- Standard46 pagesEnglish and French language
sale 15% off
IEC TR 62362:2020 is available as IEC TR 62362:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC/TR 62362: 2020 which is a technical report, provides information on the specification of optical fibre cables with respect to the mechanical, ingress, climatic and chemical or electromagnetic characteristics (MICE) as classified in ISO/IEC 11801-1. In this classification system, each letter...view more
- Technical report20 pagesEnglish language
sale 15% off
This part of IEC 60794-1 defines test procedures to be used in establishing uniform
requirements for the environmental performance of
• optical fibre cables for use with telecommunication equipment and devices employing similar
techniques, and
• cables having a combination of both optical fibres and electrical conductors.
Throughout this document, the wording "optical cable" can also include optical fibre units,
microduct fibre units, etc.
This document defines a test standard to determin...view more
- Standard16 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of IEC 62614 describes the launch condition requirements used for measuring
multimode attenuation in passive components and in installed cable plants.
In this document, the fibre types that are addressed include category A1-OMx, where x = 2, 3,
4 and 5 (50 μm/125 μm), and A1-OM1 (62,5 μm/125 μm) multimode fibres, as specified in
IEC 60793-2-10. The nominal test wavelengths detailed are 850 nm and 1 300 nm. This
document can be suitable for multimode attenuation measurements for ot...view more
- Standard15 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC TR 62349:2014(E) applies to polarization-maintaining (PM) optical fibres. The object of this report is to define test procedures to be used in establishing uniform requirements for the geometrical and transmission properties of PM fibres. This second edition cancels and replaces the first edition published in 2005. It constitutes a technical revision. In this edition, guidance of measurement methods and test procedures for dimensional characteristics, cut-off wavelength, mode field diameter ...view more
- Technical report23 pagesEnglish language
sale 15% off
IEC 60794-1-215:2020 defines test procedures to be used in establishing uniform requirements for the environmental performance of
- optical fibre cables for use with telecommunication equipment and devices employing similar techniques, and
- cables having a combination of both optical fibres and electrical conductors.
Throughout this document, the wording "optical cable" can also include optical fibre units, microduct fibre units, etc. This document defines a test standard to determine the ab...view more
- Standard26 pagesEnglish and French language
sale 15% off
This part of IEC 61753 contains the minimum test and measurement requirements and
severities which a fibre optic isolator as specified by IEC 61202-1 satisfies in order to be
categorized as meeting the requirements of isolators used in controlled environments as
specified in IEC 61753-1. The requirements cover single-mode pigtailed style polarization
independent isolators for category C used in controlled environments.
- Standard26 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment22 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment22 pagesEnglish language
sale 10% off- e-Library read for1 day