Fixed capacitors for use in electronic equipment - Part 24: Sectional specification - Surface mount fixed tantalum electrolytic capacitors with conductive polymer solid electrolyte

This part of IEC 60384 is applicable to tantalum electrolytic capacitors with conductive polymer solid electrolyte. These capacitors are primarily intended to be mounted direct on to substrates for hybrid circuits or to printed boards. Fixed tantalum electrolytic chip capacitors with solid (MnO2) are not included but are covered by IEC 60384-3. The object of this standard is to prescribe preferred ratings and characteristics and to select from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification shall be of equal or higher performance level, because lower performance levels are not permitted.

Festkondensatoren zur Verwendung in Geräten der Elektronik - Teil 24: Rahmenspezifikation - Oberflächenmontierbare Tantal-Elektrolyt-Kondensatoren mit leitfähigem Polymerfestkörper-Elektrolyten

Condensateurs fixes utilisés dans les équipements électroniques - Partie 24: Spécification intermédiaire - Condensateurs fixes électrolytiques au tantale pour montage en surface à électrolyte solide en polymère conducteur

Nespremenljivi kondenzatorji za elektronsko opremo - 24. del: Področna specifikacija - Nespremenljivi tantalovi elektrolitski kondenzatorji s prevodnim polimernim trdim elektrolitom za površinsko montažo (IEC 60384-24:2006)

General Information

Status
Withdrawn
Publication Date
03-Aug-2006
Technical Committee
Drafting Committee
Parallel Committee
Current Stage
6060 - Document made available
Due Date
04-Aug-2006
Completion Date
04-Aug-2006

RELATIONS

Buy Standard

Standard
EN 60384-24:2007
English language
29 pages
sale 10% off
Preview
sale 10% off
Preview

e-Library read for
1 day

Standards Content (sample)

SLOVENSKI STANDARD
SIST EN 60384-24:2007
01-januar-2007
1HVSUHPHQOMLYLNRQGHQ]DWRUML]DHOHNWURQVNRRSUHPRGHO3RGURþQD
VSHFLILNDFLMD1HVSUHPHQOMLYLWDQWDORYLHOHNWUROLWVNLNRQGHQ]DWRUMLVSUHYRGQLP
SROLPHUQLPWUGLPHOHNWUROLWRP]DSRYUãLQVNRPRQWDåR ,(&

Fixed capacitors for use in electronic equipment -- Part 24: Sectional specification -

Surface mount fixed tantalum electrolytic capacitors with conductive polymer solid

electrolyte
Festkondensatoren zur Verwendung in Geräten der Elektronik -- Teil 24:
Rahmenspezifikation - Oberflächenmontierbare Tantal-Elektrolyt-Kondensatoren mit
leitfähigem Polymerfestkörper-Elektrolyten
Condensateurs fixes utilisés dans les équipements électroniques -- Partie 24:

Spécification intermédiaire - Condensateurs fixes électrolytiques au tantale pour

montage en surface à électrolyte solide en polymère conducteur
Ta slovenski standard je istoveten z: EN 60384-24:2006
ICS:
31.060.40 Tantalski elektrolitni Tantalum electrolytic
kondenzatorji capacitors
SIST EN 60384-24:2007 en

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
SIST EN 60384-24:2007
---------------------- Page: 2 ----------------------
SIST EN 60384-24:2007
EUROPEAN STANDARD
EN 60384-24
NORME EUROPÉENNE
August 2006
EUROPÄISCHE NORM
ICS 31.060.040; 31.060.50
English version
Fixed capacitors for use in electronic equipment
Part 24: Sectional specification –
Surface mount fixed tantalum electrolytic capacitors
with conductive polymer solid electrolyte
(IEC 60384-24:2006)
Condensateurs fixes utilisés dans Festkondensatoren zur Verwendung
les équipements électroniques in Geräten der Elektronik
Partie 24: Spécification intermédiaire – Teil 24: Rahmenspezifikation –
Condensateurs fixes électrolytiques Oberflächenmontierbare
au tantale pour montage en surface
Tantal-Elektrolyt-Kondensatoren
à électrolyte solide en polymère mit leitfähigem Polymerfestkörper-
conducteur Elektrolyten
(CEI 60384-24:2006) (IEC 60384-24:2006)

This European Standard was approved by CENELEC on 2006-07-01. CENELEC members are bound to comply

with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard

the status of a national standard without any alteration.

Up-to-date lists and bibliographical references concerning such national standards may be obtained on

application to the Central Secretariat or to any CENELEC member.

This European Standard exists in three official versions (English, French, German). A version in any other

language made by translation under the responsibility of a CENELEC member into its own language and notified

to the Central Secretariat has the same status as the official versions.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, the Czech

Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,

Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,

Sweden, Switzerland and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels

© 2006 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.

Ref. No. EN 60384-24:2006 E
---------------------- Page: 3 ----------------------
SIST EN 60384-24:2007
EN 60384-24:2006 - 2 -
Foreword

The text of document 40/1731/FDIS, future edition 1 of IEC 60384-24, prepared by IEC TC 40, Capacitors

and resistors for electronic equipment, was submitted to the IEC-CENELEC parallel vote and was

approved by CENELEC as EN 60384-24 on 2006-07-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2007-04-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2009-07-01
Annex ZA has been added by CENELEC.
__________
Endorsement notice

The text of the International Standard IEC 60384-24:2006 was approved by CENELEC as a European

Standard without any modification.

Editorial modification to text of IEC 60384-24:2006: In Clause 2, delete the reference to IEC 62378.

__________
---------------------- Page: 4 ----------------------
SIST EN 60384-24:2007
- 3 - EN 60384-24:2006
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications

The following referenced documents are indispensable for the application of this document. For dated

references, only the edition cited applies. For undated references, the latest edition of the referenced

document (including any amendments) applies.

NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD

applies.
Publication Year Title EN/HD Year
IEC 60063 1963 Preferred number series for resistors and - -
A1 1967 capacitors - -
A2 1977 - -
1) 2)
IEC 60068-1 - Environmental testing EN 60068-1 1994
Part 1: General and guidance
1) 2)
IEC 60068-2-14 - Environmental testing EN 60068-2-14 1999
Part 2: Tests - Test N: Change of temperature
IEC 60068-2-58 2004 Environmental testing EN 60068-2-58 2004
Part 2-58: Tests - Test Td: Test methods for + corr. December 2004
solderability, resistance to dissolution of
metallization and to soldering heat of surface
mounting devices (SMD)
IEC 60384-1 (mod) 1999 Fixed capacitors for use in electronic EN 60384-1 2001
equipment + corr. October 2001
Part 1: Generic specification
IEC 60410 - Sampling plans and procedures for inspection - -
by attributes
ISO 3 1973 Preferred numbers - Series of preferred - -
numbers
Undated reference.
Valid edition at date of issue.
---------------------- Page: 5 ----------------------
SIST EN 60384-24:2007
---------------------- Page: 6 ----------------------
SIST EN 60384-24:2007
INTERNATIONAL IEC
STANDARD 60384-24
First edition
2006-06
Fixed capacitors for use in electronic equipment –
Part 24:
Sectional specification –
Surface mount fixed tantalum electrolytic
capacitors with conductive polymer solid
electrolyte
 IEC 2006  Copyright - all rights reserved

No part of this publication may be reproduced or utilized in any form or by any means, electronic or

mechanical, including photocopying and microfilm, without permission in writing from the publisher.

International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland

Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch

PRICE CODE
Commission Electrotechnique Internationale U
International Electrotechnical Commission
МеждународнаяЭлектротехническаяКомиссия
For price, see current catalogue
---------------------- Page: 7 ----------------------
SIST EN 60384-24:2007
– 2 – 60384-24  IEC:2006(E)
CONTENTS

FOREWORD...........................................................................................................................3

1 General ............................................................................................................................6

1.1 Scope......................................................................................................................6

1.2 Object .....................................................................................................................6

1.3 Normative references ..............................................................................................6

1.4 Information to be given in a detail specification .......................................................7

1.5 Terms and definitions ..............................................................................................8

1.6 Marking ...................................................................................................................8

2 Preferred rating and characteristics ..................................................................................8

2.1 Preferred characteristics .........................................................................................8

2.2 Preferred values of ratings ......................................................................................9

3 Quality assessment procedures......................................................................................10

3.1 Primary stage of manufacture................................................................................10

3.2 Structurally similar components.............................................................................10

3.3 Declaration conformity (basic requirements)..........................................................10

3.4 Test schedule and requirement for initial assessment (mandatory and

optional tests) .......................................................................................................10

3.5 Quality conformance inspection.............................................................................19

4 Test and measurement procedures.................................................................................20

4.1 Preliminary drying .................................................................................................20

4.2 Measuring conditions ............................................................................................21

4.3 Mounting ...............................................................................................................21

4.4 Visual examination and check of dimensions.........................................................21

4.5 Electrical tests.......................................................................................................21

4.6 Resistance to soldering heat .................................................................................22

4.7 Solderability ..........................................................................................................23

4.8 Shear test .............................................................................................................23

4.9 Substrate bending test ..........................................................................................23

4.10 Rapid change of temperature ................................................................................23

4.11 Climatic sequence .................................................................................................24

4.12 Damp heat, steady state........................................................................................24

4.13 Characteristics at high and low temperature ..........................................................25

4.14 Surge ....................................................................................................................25

4.15 Endurance.............................................................................................................25

4.16 Component solvent resistance (if applicable).........................................................26

4.17 Solvent resistance of marking (if applicable)..........................................................26

4.18 High surge current (if applicable)...........................................................................26

4.19 Storage at high temperature ..................................................................................26

---------------------- Page: 8 ----------------------
SIST EN 60384-24:2007
60384-24  IEC:2006(E) – 3 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT –
Part 24: Sectional specification – Surface mount fixed tantalum
electrolytic capacitors with conductive polymer solid electrolyte
FOREWORD

1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising

all national electrotechnical committees (IEC National Committees). The object of IEC is to promote

international co-operation on all questions concerning standardization in the electrical and electronic fields. To

this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,

Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC

Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested

in the subject dealt with may participate in this preparatory work. International, governmental and non-

governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely

with the International Organization for Standardization (ISO) in accordance with conditions determined by

agreement between the two organizations.

2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international

consensus of opinion on the relevant subjects since each technical committee has representation from all

interested IEC National Committees.

3) IEC Publications have the form of recommendations for international use and are accepted by IEC National

Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC

Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any

misinterpretation by any end user.

4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications

transparently to the maximum extent possible in their national and regional publications. Any divergence

between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in

the latter.

5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any

equipment declared to be in conformity with an IEC Publication.

6) All users should ensure that they have the latest edition of this publication.

7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and

members of its technical committees and IEC National Committees for any personal injury, property damage or

other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and

expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC

Publications.

8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is

indispensable for the correct application of this publication.

9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of

patent rights. IEC shall not be held responsible for identifying any or all such patent rights.

International Standard IEC 60384-24 has been prepared by IEC technical committee 40:

Capacitors and resistors for electronic equipment.
The text of this standard is based on the following documents:
FDIS Report on voting
40/1731/FDIS 40/1754/RVD

Full information on the voting for the approval of this standard can be found in the report on

voting indicated in the above table.

This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

---------------------- Page: 9 ----------------------
SIST EN 60384-24:2007
– 4 – 60384-24  IEC:2006(E)

IEC 60384 consists of the following parts, under the general title Fixed capacitors for use in

electronic equipment:
Part 1: Generic specification

Part 2: Sectional specification: Fixed metallized polyethylene-terephthalate film dielectric

d.c. capacitors
Part 3: Sectional specification: Fixed tantalum chip capacitors

Part 4: Sectional specification: Aluminium electrolytic capacitors with solid and non-solid

electrolyte

Part 5: Sectional specification: Fixed mica delectric d.c. capacitors with a rated voltage

not exceeding 3 000 V – Selection of methods of test and general requirements

Part 6: Sectional specification: Fixed metallized polycarbonate film dielectric d.c.

capacitors

Part 7: Sectional specification: Fixed polystyrene film dielectric metal foil d.c. capacitors

Part 8: Sectional specification: Fixed capacitors of ceramic dielectric, Class 1
Part 9: Sectional specification: Fixed capacitors of ceramic dielectric, Class 2

Part 11: Sectional specification: Fixed polyethylene-terephthalate film dielectric metal foil

d.c. capacitors

Part 12: Sectional specification: Fixed polycarbonate film dielectric metal foil d.c.

capacitors

Part 13: Sectional specification: Fixed polypropylene film dielectric metal foil d.c.

capacitors

Part 14: Sectional specification: Fixed capacitors for electromagnetic interference

suppression and connection to the supply mains

Part 15: Sectional specification: Fixed tantalum capacitors with non-solid or solid

electrolyte

Part 16: Sectional specification: Fixed metallized polypropylene film dielectric d.c.

capacitors

Part 17: Sectional specification: Fixed metallized polypropylene film dielectric a.c. and

pulse capacitors

Part 18: Sectional specification: Fixed aluminium electrolytic chip capacitors with solid and

non-solid electrolyte

Part 19: Sectional specification: Fixed metallized polyethylene-terephthalate film dielectric

chip d.c. capacitors

Part 20: Sectional specification: Fixed metallized polyphenylene sulphide film dielectric

chip d.c. capacitors

Part 21: Sectional specification: Fixed surface mount multilayer capacitors of ceramic

dielectric, Class 1

Part 22: Sectional specification: Fixed surface mount multilayer capacitors of ceramic

dielectric, Class 2

Part 23: Sectional specification: Fixed surface mount metallized polyethylene naphthalate

film dielectric d.c. capacitors

Part 24: Sectional specification: Surface mount fixed tantalum electrolytic capacitors with

conductive polymer solid electrolyte

Part 25: Sectional specification: Surface mount fixed aluminium electrolyte capacitors with

conductive polymer solid electrolyte

All sectional specifications mentioned above do have one or more blank detail specifications

being a supplementary document, containing requirements for style, layout and minimum

content of detail specifications.
---------------------- Page: 10 ----------------------
SIST EN 60384-24:2007
60384-24 © IEC:2006(E) – 5 –

The committee has decided that the contents of this publication will remain unchanged until

the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in

the data related to the specific publication. At this date, the publication will be

• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
A bilingual version of this publication may be issued at a later date.
The contents of the corrigendum of October 2006 have been included in this copy.
---------------------- Page: 11 ----------------------
SIST EN 60384-24:2007
– 6 – 60384-24 © IEC:2006(E)
FIXED CAPACITORS FOR USE IN ELECTRONIC EQUIPMENT –
Part 24: Sectional specification – Surface mount fixed tantalum
electrolytic capacitors with conductive polymer solid electrolyte
1 General
1.1 Scope

This part of IEC 60384 is applicable to tantalum electrolytic capacitors with conductive

polymer solid electrolyte. These capacitors are primarily intended to be mounted direct on to

substrates for hybrid circuits or to printed boards.

Fixed tantalum electrolytic chip capacitors with solid (MnO ) are not included but are covered

by IEC 60384-3.
1.2 Object

The object of this standard is to prescribe preferred ratings and characteristics and to select

from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring

methods and to give general performance requirements for this type of capacitor. Test

severities and requirements prescribed in detail specifications referring to this sectional

specification shall be of equal or higher performance level, because lower performance levels

are not permitted.
1.3 Normative references

The following referenced documents are indispensable for the application of this document.

For dated references, only the edition cited applies. For undated references, the latest edition

of the referenced document (including any amendments) applies.
IEC 60063:1963, Preferred number series for resistors and capacitors
Amendment 1 (1967)
Amendment 2 (1977)
IEC 60068-1: Environmental testing – Part 1: General and guidance

IEC 60068-2-14: Environmental testing – Part 2-14:Tests – Test N: Change of temperature

IEC 60068-2-58:2004, Environmental testing – Part 2-58: Tests – Test Td: Test methods for

solderability, resistance to dissolution of metallization and to soldering heat of surface

mounting devices (SMD)

IEC 60384-1:1999, Fixed capacitors for use in electronic equipment – Part 1: Generic

specification
IEC 60410: Sampling plans and procedures for inspection by attributes
ISO 3:1973, Preferred numbers – Series of preferred numbers
---------------------- Page: 12 ----------------------
SIST EN 60384-24:2007
60384-24  IEC:2006(E) – 7 –
1.4 Information to be given in a detail specification

Detail specifications shall be derived from the relevant blank detail specification.

Detail specifications shall not specify requirements inferior to those of the generic, sectional

or blank detail specification. When more severe requirements are included, they shall be

listed in 1.9 of the detail specification and indicated in the test schedules, for example, by an

asterisk.

NOTE The information given in 1.4.1 may, for convenience, be presented in tabular form.

The following information shall be given in each detail specification and the values quoted

shall preferably be selected from those given in the appropriate clause of this sectional

specification.
1.4.1 Outline drawing and dimensions

There shall be an illustration of the surface mount capacitors as an aid to easy recognition

and for comparison of the surface mount capacitors with others. Dimensions and their

associated tolerances, which affect interchangeability and mounting, shall be given in the

detail specification. All dimensions shall preferably be stated in millimetres; however, when

the original dimensions are given in inches, the converted metric dimensions in millimetres

shall be added.

Normally, the numerical values shall be given for the length, width and height of the body.

When necessary, for example, when a number of case sizes are covered by a detail

specification, the dimensions and their associated tolerances shall be placed in a table below

the drawing. When the configuration is other than described above, the detail specification

shall state such dimensional information as will adequately describe the capacitors.

1.4.2 Mounting

The detail specification shall give guidance on methods of mounting for normal use. Mounting

for test and measurement purposes (when required) shall be in accordance with 4.3 of this

sectional specification.
1.4.3 Rating and characteristics

The ratings and characteristics shall be in accordance with the relevant clauses of this

specification, together with the following.
1.4.3.1 Rated capacitance range
See 2.2.1.

NOTE When products approved to the detail specification have different ranges, the following statement should

be added: “The range of capacitance values available in each voltage range is given in IEC QC 001005”.

1.4.3.2 Particular characteristics

Additional characteristics may be listed, when they are considered necessary to specify

adequately the component for design and application purposes.
1.4.3.3 Soldering

The detail specification shall prescribe the test methods, severities and requirements

applicable for the solderability and the resistance to soldering heat tests.
---------------------- Page: 13 ----------------------
SIST EN 60384-24:2007
– 8 – 60384-24  IEC:2006(E)
1.4.4 Marking

The detail specification shall specify the content of the marking on the capacitor and on the

package. Deviations from 1.6 of this sectional specification shall be specifically stated.

1.5 Terms and definitions

For the purposes of this document, the terms and definitions of IEC 60384-1, as well as the

following, apply.
1.5.1
surface mount capacitor

capacitor whose small dimensions and nature or shape of terminations make it suitable for

surface mounting
1.6 Marking
See IEC 60384-1, 2.4, with the following details:

1.6.1 The information given in the marking is normally selected from the following list; the

relative importance of each item is indicated by its position in the list:
a) polarity of the terminations (unless identified by the construction);
b) rated capacitance;

c) rated voltage (d.c. voltage may be indicated by the symbol or );

d) tolerance on rated capacitance;
e) year and month (or week) of manufacture;
f) manufacturer’s name or trade mark;
g) climatic category;
h) manufacturer’s type designation;
i) reference to the detail specification.

1.6.2 Surface mount capacitors are generally not marked on the body. If some marking can

be applied, they shall be clearly marked with as many as possible of the above items as is

considered useful. Any duplication of information in the marking on the capacitor should be

avoided.

1.6.3 Any marking shall be legible and not easily smeared or removed by rubbing with the

finger.

1.6.4 The package containing the capacitor(s) shall be clearly marked with all the

information listed in 1.6.1, except polarity, unless this is applicable to the method of

packaging.
1.6.5 Any additional marking shall be so applied that no confusion can arise.
2 Preferred rating and characteristics
2.1 Preferred characteristics

The values given in the detail specification shall preferably be selected from the following:

---------------------- Page: 14 ----------------------
SIST EN 60384-24:2007
60384-24  IEC:2006(E) – 9 –
2.1.1 Preferred climatic categories

The surface mount capacitors covered by this specification are classified into climatic

categories according to the general rules given in IEC 60068-1.

The lower and upper category temperatures and the duration of the damp heat, steady state

test shall be chosen from the following:
Lower category temperature: -55 °C
Upper category temperature: +105 °C and +125 °C
Duration of the damp heat, steady state test: 21 days

The severities for the cold and dry heat tests are the lower and upper category temperatures

respectively.

The rated temperature shall be 85 °C or 105 °C for upper category temperature of 125 °C.

The rated temperature shall be 85 °C for an upper category temperature of 105 °C.

2.2 Preferred values of ratings
2.2.1 Rated capacitance (C )

Preferred values of rated capacitance are the values the E6 and E12 series of IEC 60063 and

their decimal multiples (× 10 , n: integer).
2.2.2 Tolerance on rated capacitance
Preferred values of tolerance on rated capacitance are: ±20 %.
2.2.3 Rated voltage (U )

The preferred values of the rated voltage are the values of the R10 series of ISO 3:

1,0 – 1,25 – 1,6 – 2,0 – 2,5 – 3,15 – 4,0 – 5,0 – 6,3 – 8,0 and their decimal multiples (× 10 , n:

integer).
2.2.4 Category voltage (U )
The category voltage for capacitors is given in Table 1.
Table 1 – Category voltages
Temperature/
Value
Voltage
T ( °C) 125 105 125
T ( °C) 85 85 105
U (V) 1,0 × U 1,0 × U
R R R
U (V) 1,15 × U 1,15 × U
RS R R
U (V)
0,8 × U 0,9 × U
R R
U (V)
0,92 × U 1,03 × U
R R
---------------------- Page: 15 ----------------------
SIST EN 60384-24:2007
– 10 – 60384-24  IEC:2006(E)
2.2.5 Surge voltage (U or U )
RS CS

The surge voltage shall be 1,15 times the rated or category voltage rounded off to the nearest

volt (see Table 1).
NOTE U is the surge voltage to rated voltage;
U is the the surge voltage to category voltage.
2.2.6 Rated temperature
The value of the rated temperature is +85 °C and +105 °C.
3 Quality assessment procedures
3.1 Primary stage of manufacture
The primary stage of manufacture is the forming of the oxide film.
3.2 Structurally similar components

Capacitors considered as being structurally similar are capacitors produced with similar

processes and materials, though they may be of different case sizes and values.
3.3 Declaration conformity (basic requirements)
3.4 Test schedule and requirement for initial assessment (mandatory and optional
tests)
The procedures for qualification approval testing are given in IEC 60384-1, 3.5.

The schedule to be used for qualification approval testing on the basis of lot-by-lot and

periodic tests is given in 3.5 of this specification. The procedure using a fixed sample size

schedule is given in 3.4.1 and 3.4.2 below.
3.4.1 Qualification approval on the basis of the fixed sample size procedures
The fixed sample size procedure is described in IEC 60410. The sample shall be

representative of the range of capacitors for which approval is sought. This may or may not be

the complete range covered by the detail specification.

For each temperature characteristic the sample shall consist of specimens of capacitors of

maximu
...

Questions, Comments and Discussion