Fibre optic connector interfaces - Part 4: Type SC connector family

EN following parallel vote

Steckgesichter von Lichtwellenleiter-Steckverbindern - Teil 4: Bauart SC Steckverbinderfamilie

Interfaces de connecteurs pour fibres optiques - Partie 4: Famille de connecteurs du type SC

Fibre optic connector for interfaces - Part 4: Type SC connector family - Amendment A2 (IEC 61754-4:1997/A2:2001)

General Information

Status
Withdrawn
Publication Date
22-Jul-2001
Withdrawal Date
31-May-2004
Current Stage
9960 - Withdrawal effective - Withdrawal
Start Date
26-Aug-2014
Completion Date
26-Aug-2014

Relations

Buy Standard

Amendment
EN 61754-4:1997/A2:2002
English language
21 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2002
Fibre optic connector for interfaces - Part 4: Type SC connector family -
Amendment A2 (IEC 61754-4:1997/A2:2001)
Fibre optic connector interfaces -- Part 4: Type SC connector family
Steckgesichter von Lichtwellenleiter-Steckverbindern -- Teil 4: Bauart SC
Steckverbinderfamilie
Interfaces de connecteurs pour fibres optiques -- Partie 4: Famille de connecteurs du
type SC
Ta slovenski standard je istoveten z: EN 61754-4:1997/A2:2001
ICS:
33.180.20 3RYH]RYDOQHQDSUDYH]D Fibre optic interconnecting
RSWLþQDYODNQD devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EUROPEAN STANDARD EN 61754-4/A2
NORME EUROPÉENNE
EUROPÄISCHE NORM July 2001
ICS 33.180.20
English version
Fibre optic connector interfaces
Part 4: Type SC connector family
(IEC 61754-4:1997/A2:2001)
Interfaces de connecteurs pour fibres Steckgesichter von Lichtwellenleiter-
optiques Steckverbindern
Partie 4: Famille de connecteurs Teil 4: Bauart SC Steckverbinderfamilie
du type SC (IEC 61754-4:1997/A2:2001)
(CEI 61754-4:1997/A2:2001)
This amendment A2 modifies the European Standard EN 61754-4:1997; it was approved by CENELEC
on 2001-06-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this amendment the status of a national standard without any
alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway,
Portugal, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61754-4:1997/A2:2001 E

Foreword
The text of document 86B/1447/FDIS, future amendment 2 to IEC 61754-4:1997, prepared by
SC 86B, Fibre optic interconnecting devices and passive components, of IEC TC 86, Fibre optics, was
submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as amendment A2 to
EN 61754-4:1997 on 2001-06-01.
The following dates were fixed:
– latest date by which the amendment has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2002-03-01
– latest date by which the national standards conflicting
with the amendment have to be withdrawn (dow) 2004-06-01
__________
Endorsement notice
The text of amendment 2:2001 to the International Standard IEC 61754-4:1997 was approved by
CENELEC as an amendment to the European Standard without any modification.
__________
NORME
CEI
INTERNATIONALE IEC
61754-4
INTERNATIONAL
STANDARD
AMENDEMENT 2
AMENDMENT 2
2001-02
Amendement 2
Interfaces de connecteurs pour fibres optiques –
Partie 4:
Famille de connecteurs du type SC
Amendment 2
Fibre optic connector interfaces –
Part 4:
Type SC connector family
© IEC 2001 Droits de reproduction réservés ⎯ Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http://www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
R
PRICE CODE
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue

61754-4 Amend. 2 © IEC:2001 – 3 –
FOREWORD
This amendment has been prepared by subcommittee 86B: Fibre optic interconnecting
devices and passive components, of IEC technical committee 86: Fibre optics.
The text of this amendment is based on the following documents:
FDIS Report on voting
86B/1447/FDIS 86B/1500/RVD
Full information on the voting for the approval of this amendment can be found in the report
on voting indicated in the above table.
The committee has decided that the contents of the base publication and its amendments will
remain unchanged until 2002. At this date, the publication will be:
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
___________
Page 7
2 Description
Add, after the existing paragraph, the following new text:
This part of IEC 61754 defines the standard interface dimensions of active device receptacles
for the type SC connectors. The receptacles are used to retain the connector plug and
mechanically maintain the optical datum target of the plugs at a defined position within the
receptacle housings.
3 Interfaces
Add, after Interface 4.2: simplex adaptor connector interface – push/pull, the following new
standard interfaces:
Interface 4-X1: simplex active device receptacle interface – for angled PC connector plug
Interface 4-X2: simplex active device receptacle interface – for PC connector plug
Interface 4-X3: duplex active device receptacle interface – for angled PC connector plug
Interface 4-X4: duplex active device receptacle interface – for PC connector plug

61754-4 Amend. 2 © IEC:2001 – 5 –
Add, after the last line "Interface 4-1 mates with Interface 4-2", the following new figures and
tables:
Interface Interface 4-X1 Interface 4-X2 Interface 4-X3 Interface 4-X4
(simplex, APC) (simplex, PC) (duplex, APC) (duplex, PC)
Interface 4-1 Not mate Mate Not mate Mate
(simplex plug, PC)
Interface 4-5 Mate Not mate Mate Not mate
(simplex plug, APC)
Interface 4-3 Not mate Not mate Not mate Mate
(duplex plug, PC)
Interface 4-8 Not mate Not mate Mate Not mate
(duplex plug, APC)
61754-4 Amend. 2 © IEC:2001 – 7 –
X
R H
U
J
T K
C
Y
A’
A
I
AC
AE
L
Guide groove
B
S
Z
Guide groove
V
Projected from B direction
Cross-section A-A’
OC
Ferrule
Optional datum target
OD
Detail of C – Mechanical stop feature IEC  182/01
Figure 7a – Simplex active device receptacle interface for angled PC connector plug
O
D
P
∅B
AA
AB
BA ∅A
OA
AD
BB
61754-4 Amend. 2 © IEC:2001 – 9 –
Table 7a – Dimensions of the simplex active device receptacle interface
for angled PC connector plug
Dimensions
Reference Notes
Minimum Maximum
A See table 7b
B 4,39 mm 4,79 mm
D 4,9 mm 5,5 mm
6,9 mm 7,1 mm 1
H
I 0,4 mm 0,8 mm
J 5,51 mm 5,90 mm
K 0,06 mm 1,00 mm
L 1,9 mm 2,1 mm
O 2,0 mm 2,2 mm
P 9,0 mm 9,2 mm
R 7,4 mm 7,5 mm
S 1,0 mm 1,1 mm Radius
T 3,80 mm 4,04 mm
U 5,0 mm 5,3 mm
V 0,6 mm 1,6 mm
AA 27° 33°
AB 0,8 mm 1,0 mm
AC 0,4 mm 0,6 mm Radius
AD 0,7 mm 0,8 mm
AE 0,4 mm 0,6 mm
BA 5,4 mm 5,6 mm 2
BB 11,0 mm 11,2 mm 2
1, see table 7d
OA
OC 0 mm 0,05 mm Radius
OD 1, see table 7d
NOTE 1 An example of a mechanical stop feature is shown in figure 7a. A mechanical stop feature is required
in order to bring the fibre tip to the optical datum target. Due to the ferrule tip geometry variations, some means
of providing a mechanical reference stop for all types is required. The mechanical stop feature incorporated into
the reference should be capable of maintaining the optical datum target of both the fibre and the receptacle
within the clearances specified in table 7d depending upon the application.
NOTE 2 This may be a structure as shown by a dashed line shown in figure 7a.

61754-4 Amend. 2 © IEC:2001 – 11 –
Table 7b – Alignment feature grade
Dimensions
Grade Notes
Minimum Maximum
1 2,500 mm 2,502 mm 1 and 2
2 2,501 mm 2,504 mm 1 and 2
3 2,501 mm 2,510 mm 1 and 2
4 2,501 mm 2,525 mm 1 and 2
5 Resilient sleeve, 2 and 3
NOTE 1 The connector alignment feature is a rigid bore.
NOTE 2 Add the grade number to the interface reference number.
NOTE 3 The connector alignment feature is a resilient sleeve. The feature accepts a gauge pin to the
centre of the receptacle with a force of 2,9 N to 5,9 N. The centre of the receptacle is defined by the right
side position of the dimension H. The measurement is performed using a single gauge pin.
C or R
CN
IEC  183/01
Figure 7b – Pin gauge for receptacle
Table 7c – Pin gauge dimensions
Dimensions
Reference Notes
Minimum Maximum
CK 2,4985 mm 2,4995 mm Surface roughness grade N4 (0,2 µm radius)
CL 2,8 mm 4,8 mm
CN 7 mm 15 mm
∅CK
∅CL
61754-4 Amend. 2 © IEC:2001 – 13 –
Table 7d – Mechanical stop feature grade
Dimensions Dimensions
µm
Grade Notes
OA OA OD
minimum maximum clearance
A 0,150 mm 0,2 mm 15 1 and 2
±
B 0,150 mm 0,35 mm
±40 1 and 2
N 0,150 mm – 1 and 2
X 2 and 3
NOTE 1 The connector alignment feature is a rigid bore.
NOTE 2 Add the grade number to the alignment feature g
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.