ETSI EN 300 119-7 V1.1.1 (2015-02)
Environmental Engineering (EE); European telecommunication standard for equipment practice; Part 7: Engineering requirements for Subracks in harmonized racks and cabinets with extended features
Environmental Engineering (EE); European telecommunication standard for equipment practice; Part 7: Engineering requirements for Subracks in harmonized racks and cabinets with extended features
DEN/EE-0058
Okoljski inženiring (EE) - Evropski telekomunikacijski standard za prakso pri opremi - 7. del: Tehnične zahteve za okvire v harmoniziranih stojalih in ohišjih s razširjenimi lastnostmi
General Information
Buy Standard
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Environmental Engineering (EE) - European telecommunication standard for equipment practice - Part 7: Engineering requirements for Subracks in harmonized racks and cabinets with extended features33.050.01Telekomunikacijska terminalska oprema na splošnoTelecommunication terminal equipment in general19.040Preskušanje v zvezi z okoljemEnvironmental testingICS:Ta slovenski standard je istoveten z:EN 300 119-7 V1.1.1SIST EN 300 119-7 V1.1.1:2015en01-junij-2015SIST EN 300 119-7 V1.1.1:2015SLOVENSKI
STANDARD
SIST EN 300 119-7 V1.1.1:2015
ETSI EN 300 119-7 V1.1.1 (2015-02) Environmental Engineering (EE); European telecommunication standard for equipment practice; Part 7: Engineering requirements for Subracks in harmonized racks and cabinets
with extended features
EUROPEAN STANDARD SIST EN 300 119-7 V1.1.1:2015
ETSI ETSI EN 300 119-7 V1.1.1 (2015-02) 2
Reference DEN/EE-0058 Keywords environment, equipment practice, rack ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C Association à but non lucratif enregistrée à la Sous-Préfecture de Grasse (06) N° 7803/88
Important notice The present document can be downloaded from: http://www.etsi.org/standards-search The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http://portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: https://portal.etsi.org/People/CommiteeSupportStaff.aspx Copyright Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI. The content of the PDF version shall not be modified without the written authorization of ETSI. The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2015. All rights reserved.
DECTTM, PLUGTESTSTM, UMTSTM and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association. SIST EN 300 119-7 V1.1.1:2015
ETSI ETSI EN 300 119-7 V1.1.1 (2015-02) 3 Contents Intellectual Property Rights . 4 Foreword . 4 Modal verbs terminology . 5 1 Scope . 6 2 References . 6 2.1 Normative references . 6 2.2 Informative references . 6 3 Abbreviations . 7 4 Dimensions for subracks . 7 5 Accessibility . 7 6 Weight . 7 6.1 Unequipped subrack . 7 6.2 Equipped subrack . 7 Annex A (informative): Illustrative figures . 9 Annex B (informative): Bibliography . 12 History . 13
SIST EN 300 119-7 V1.1.1:2015
ETSI ETSI EN 300 119-7 V1.1.1 (2015-02) 4 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http://ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE). The present document is part 7 of a multi-part deliverable aimed at setting out, on a common basis, the engineering requirements for telecommunication practice, for housing equipment forming part of a public telecommunications network. ETSI EN 300 119-1 [i.1] is a general introduction and explains the terminology used. ETSI EN 300 119-2 [i.2] specifies the engineering requirements for racks and cabinets and ETSI EN 300 119-3 [i.3] specifies the engineering requirements for miscellaneous racks and cabinets. ETSI EN 300 119-5 [i.5] covers the preferred thermal management solutions for subracks, racks/cabinets and miscellaneous racks/cabinets installed indoors in restricted access locations, for the removal of heat dissipated by one or more subracks in an rack complying to the requirements of this multi-part standard. The present document specifies the engineering requirements for subracks mounted in harmonized racks and cabinets with extended features. The present document applies to all telecommunications equipment forming part of the public telecommunications network. The present document, ETSI EN 300 119-7, is defining extension to the existing parts of the standard to harmonize dimensions and to extend rack installation capabilities. These extended features are: • mounting bracket depth adjustment only on subrack level (as normally done in many other standardized equipment practices; see 19 inches) • common position of mounting brackets for both 300 mm and 600 mm depth • recessed subrack mounting plane compared to ETSI EN 300 119-3 [i.3] and ETSI EN 300 119-4 [i.4] to allow more room for cable management and better cable access from front/rear aisle • design subrack mounting plane in a manner so that not only 600 mm deep rack is a earthquake proof design but also the 300 mm rack (600 mm: ~7 inches deep upright; 300 mm ~3,5 inches deep upright; commonality with EIA rack standard for SNBF) • make ETSI mounting principle similar to SNBF (5 inches deep upright) which is used in USA telecommunication offices to gain more commonality for international markets • define extra front side cabling space for accommodating optical and electrical I
...
ETSI EN 300 119-7 V1.1.1 (2015-02)
EUROPEAN STANDARD
Environmental Engineering (EE);
European telecommunication standard
for equipment practice;
Part 7: Engineering requirements for
Subracks in harmonized racks and cabinets
with extended features
---------------------- Page: 1 ----------------------
2 ETSI EN 300 119-7 V1.1.1 (2015-02)
Reference
DEN/EE-0058
Keywords
environment, equipment practice, rack
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
The present document can be downloaded from:
http://www.etsi.org/standards-search
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the
print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, please send your comment to one of the following services:
https://portal.etsi.org/People/CommiteeSupportStaff.aspx
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2015.
All rights reserved.
TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI
---------------------- Page: 2 ----------------------
3 ETSI EN 300 119-7 V1.1.1 (2015-02)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 6
3 Abbreviations . 7
4 Dimensions for subracks . 7
5 Accessibility . 7
6 Weight . 7
6.1 Unequipped subrack . 7
6.2 Equipped subrack . 7
Annex A (informative): Illustrative figures . 9
Annex B (informative): Bibliography . 12
History . 13
ETSI
---------------------- Page: 3 ----------------------
4 ETSI EN 300 119-7 V1.1.1 (2015-02)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://ipr.etsi.org).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE).
The present document is part 7 of a multi-part deliverable aimed at setting out, on a common basis, the engineering
requirements for telecommunication practice, for housing equipment forming part of a public telecommunications
network. ETSI EN 300 119-1 [i.1] is a general introduction and explains the terminology used. ETSI EN 300 119-2 [i.2]
specifies the engineering requirements for racks and cabinets and ETSI EN 300 119-3 [i.3] specifies the engineering
requirements for miscellaneous racks and cabinets. ETSI EN 300 119-5 [i.5] covers the preferred thermal management
solutions for subracks, racks/cabinets and miscellaneous racks/cabinets installed indoors in restricted access locations,
for the removal of heat dissipated by one or more subracks in an rack complying to the requirements of this multi-part
standard. The present document specifies the engineering requirements for subracks mounted in harmonized racks and
cabinets with extended features.
The present document applies to all telecommunications equipment forming part of the public telecommunications
network.
The present document, ETSI EN 300 119-7, is defining extension to the existing parts of the standard to harmonize
dimensions and to extend rack installation capabilities.
These extended features are:
• mounting bracket depth adjustment only on subrack level (as normally done in many other standardized
equipment practices; see 19 inches)
• common position of mounting brackets for both 300 mm and 600 mm depth
• recessed subrack mounting plane compared to ETSI EN 300 119-3 [i.3] and ETSI EN 300 119-4 [i.4] to allow
more room for cable management and better cable access from front/rear aisle
• design subrack mounting plane in a manner so that not only 600 mm deep rack is a earthquake proof design
but also the 300 mm rack (600 mm: ~7 inches deep upright; 300 mm ~3,5 inches deep upright; commonality
with EIA rack standard for SNBF)
• make ETSI mounting principle similar to SNBF (5 inches deep upright) which is used in USA
telecommunication offices to gain more commonality for international markets
• define extra front side cabling space for accommodating optical and electrical I/O cables
Illustrative figures are contained in annex A.
The present document is part 7 of a multi-part deliverable. Full details of the entire series can be found in part 1 [i.1].
ETSI
---------------------- Page: 4 ----------------------
5 ETSI EN 300 119-7 V1.1.1 (2015-02)
National transposition dates
Date of adoption of this EN: 19 February 2015
Date of latest announcement of this EN (doa): 31 May 2015
Date of latest publication of ne
...
Draft ETSI EN 300 119-7 V1.0.0 (2014-10)
EUROPEAN STANDARD
Environmental Engineering (EE);
European telecommunication standard
for equipment practice;
Part 7: Engineering requirements for
Subracks in harmonized racks and cabinets
with extended features
---------------------- Page: 1 ----------------------
2 Draft ETSI EN 300 119-7 V1.0.0 (2014-10)
Reference
DEN/EE-0058
Keywords
environment, equipment practice, rack
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
The present document can be downloaded from:
http://www.etsi.org
The present document may be made available in electronic versions and/or in print. The content of any electronic and/or
print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any
existing or perceived difference in contents between such versions and/or in print, the only prevailing document is the
print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, please send your comment to one of the following services:
http://portal.etsi.org/chaircor/ETSI_support.asp
Copyright Notification
No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying
and microfilm except as authorized by written permission of ETSI.
The content of the PDF version shall not be modified without the written authorization of ETSI.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2014.
All rights reserved.
TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI
---------------------- Page: 2 ----------------------
3 Draft ETSI EN 300 119-7 V1.0.0 (2014-10)
Contents
Intellectual Property Rights . 4
Foreword . 4
Modal verbs terminology . 5
1 Scope . 6
2 References . 6
2.1 Normative references . 6
2.2 Informative references . 6
3 Abbreviations . 7
4 Dimensions for subracks . 7
5 Accessibility . 7
6 Weight . 7
6.1 Unequipped subrack . 7
6.2 Equipped subrack . 7
Annex A (informative): Illustrative figures . 9
Annex B (informative): Bibliography . 12
History . 13
ETSI
---------------------- Page: 3 ----------------------
4 Draft ETSI EN 300 119-7 V1.0.0 (2014-10)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://ipr.etsi.org).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web
server) which are, or may be, or may become, essential to the present document.
Foreword
This draft European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE),
and is now submitted for the combined Public Enquiry and Vote phase of the ETSI standards EN Approval Procedure.
The present document is part 7 of a multi-part deliverable aimed at setting out, on a common basis, the engineering
requirements for telecommunication practice, for housing equipment forming part of a public telecommunications
network. ETSI EN 300 119-1 [i.1] is a general introduction and explains the terminology used. ETSI EN 300 119-2 [i.2]
specifies the engineering requirements for racks and cabinets and ETSI EN 300 119-3 [i.3] specifies the engineering
requirements for miscellaneous racks and cabinets. ETSI EN 300 119-5 [i.5] covers the preferred thermal management
solutions for subracks, racks/cabinets and miscellaneous racks/cabinets installed indoors in restricted access locations,
for the removal of heat dissipated by one or more subracks in an rack complying to the requirements of this multi-part
standard. The present document specifies the engineering requirements for subracks mounted in harmonized racks and
cabinets with extended features.
The present document applies to all telecommunications equipment forming part of the public telecommunications
network.
The present document, ETSI EN 300 119-7, is defining extension to the existing parts of the standard to harmonize
dimensions and to extend rack installation capabilities.
These extended features are:
• mounting bracket depth adjustment only on subrack level (as normally done in many other standardized
equipment practices; see 19 inches)
• common position of mounting brackets for both 300 mm and 600 mm depth
• recessed subrack mounting plane compared to ETSI EN 300 119-3 [i.3] and ETSI EN 300 119-4 [i.4] to allow
more room for cable management and better cable access from front/rear aisle
• design subrack mounting plane in a manner so that not only 600 mm deep rack is a earthquake proof design
but also the 300 mm rack (600 mm: ~7 inches deep upright; 300 mm ~3,5 inches deep upright; commonality
with EIA rack standard for SNBF)
• make ETSI mounting principle similar to SNBF (5 inches deep upright) which is used in USA
telecommunication offices to gain more commonality for international markets
• define extra front side cabling space for accommodating optical and electrical I/O cables
Illustrative figures are contained in annex A.
The present document is part 7 of a multi-part deliverable. Full details of the entire series can be found in part 1 [i.1]
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.