IEC PAS 61169-19:2009
(Main)Radio-frequency connectors - Part 19: Sectional specification for SSMB series R.F. coaxial connectors
Radio-frequency connectors - Part 19: Sectional specification for SSMB series R.F. coaxial connectors
IEC/PAS 61169-19:2009(E) is a sectional specification providing information and rules for preparation of detail specification of SSMB series R.F. connectors together with the pro forma blank detail specification. The SSMB series connectors with characteristic impedance 50 ohm are one kind of low power miniature connectors with snap-on coupling mechanism and have the characteristics of light weight, small size, convenient connection and excellent characteristics. This connector range is suitable for the standard ranges of flexible and semi-rigid cables and is also available as a PCB mounted version. The connectors are usable up to a frequency of 3 GHz.
General Information
Relations
Standards Content (Sample)
IEC/PAS 61169-19
®
Edition 1.0 2009-03
PUBLICLY AVAILABLE
SPECIFICATION
PRE-STANDARD
Radio-frequency connectors –
Part 19: Sectional specification for SSMB series R.F. coaxial connectors
IEC/PAS 61169-19:2009(E)
---------------------- Page: 1 ----------------------
THIS PUBLICATION IS COPYRIGHT PROTECTED
Copyright © 2009 IEC, Geneva, Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email: inmail@iec.ch
Web: www.iec.ch
About the IEC
The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
ƒ Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
ƒ IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
ƒ Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
ƒ Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email: csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
---------------------- Page: 2 ----------------------
IEC/PAS 61169-19
®
Edition 1.0 2009-03
PUBLICLY AVAILABLE
SPECIFICATION
PRE-STANDARD
Radio-frequency connectors –
Part 19: Sectional specification for SSMB series R.F. coaxial connectors
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
PRICE CODE
T
ICS 33.120.30 ISBN 978-2-88910-799-5
® Registered trademark of the International Electrotechnical Commission
---------------------- Page: 3 ----------------------
– 2 – PAS 61169-19 © IEC:2009(E)
CONTENTS
FOREWORD.4
1 Scope.5
2 Normative references .5
3 Mating face and gauge information.5
3.1 Dimensions – General purpose connectors – Grade 2 .5
3.1.1 Connector with socket-centre contact .5
3.1.2 Connector with pin-centre contact.7
3.2 Gauges .8
3.2.1 Gauge pins for socket-centre contact.8
3.2.2 Test procedure .8
3.2.3 Gauge for outer contact of socket-centre contact.9
3.2.4 Test procedure .9
3.3 Dimensions – Standard test connectors – Grade 0 .10
3.3.1 Connector with socket-centre contact .10
3.3.2 Connector with pin-centre contact.11
4 Quality assessment procedures.12
4.1 General .12
4.2 Rating and characteristics (see Clause 6 of IEC 61169-1) .12
4.3 Test schedule and inspection requirements .14
4.3.1 Acceptance tests .14
4.3.2 Periodic tests .15
4.4 Procedures.17
4.4.1 Quality conformance inspection .17
4.4.2 Qualification approval and its maintenance.17
5 Instructions for preparation of detail specifications .17
5.1 Identification of the component.17
5.2 Performance.17
5.3 Marking, ordering information and related matters .18
5.4 Selection of tests, test conditions and severities.18
5.5 Blank detail specification pro-forma for type SSMB connector .19
Figure 1 – Connector with socket- centre contact.6
Figure 2 – Connector with pin-centre contact .7
Figure 3 – Gauge pins for socket-centre contact .8
Figure 4 – Outer contact sizing and retention force gauges A and B .9
Figure 5 – Connector with socket-centre contact.10
Figure 6 – Connector with pin-centre contact .11
Table 1 – Dimensions of connector with socket-centre contact.6
Table 2 – Dimensions of connector with pin-centre contact .7
Table 3 – Dimensions of gauge pins for socket-centre contact .8
Table 4 – Dimensions of gauge for outer contact .9
---------------------- Page: 4 ----------------------
PAS 61169-19 © IEC:2009(E) – 3 –
Table 5 – Dimensions of connector with socket-centre contact.10
Table 6 – Dimensions of connector with pin-centre contact .11
Table 7 – Rating and characteristics .12
Table 8 – Acceptance tests.14
Table 9 – Periodic tests .15
---------------------- Page: 5 ----------------------
– 4 – PAS 61169-19 © IEC:2009(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
RADIO-FREQUENCY CONNECTORS –
Part 19: Sectional specification for SSMB series
R.F. coaxial connectors
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
A PAS is a technical specification not fulfilling the requirements for a standard, but made
available to the public.
IEC-PAS 61169-19 has been processed by subcommittee 46F: RF and microwave passive
components, of IEC technical committee 46: Cables, wires, waveguides, R.F. connectors, R.F.
and microwave passive components and accessories.
The text of this PAS is based on the This PAS was approved for
following document: publication by the P-members of the
committee concerned as indicated in
the following document
Draft PAS Report on voting
46F/96/PAS 46F/110/RVD
Following publication of this PAS, which is a pre-standard publication, the technical committee
or subcommittee concerned may transform it into an International Standard.
This PAS shall remain valid for an initial maximum period of 3 years starting from the
publication date. The validity may be extended for a single 3-year period, following which it
shall be revised to become another type of normative document, or shall be withdrawn.
---------------------- Page: 6 ----------------------
PAS 61169-19 © IEC:2009(E) – 5 –
RADIO-FREQUENCY CONNECTORS –
Part 19: Sectional specification for SSMB series
R.F. coaxial connectors
1 Scope
This PAS is a sectional specification providing information and rules for preparation of detail
specification of SSMB series R.F. connectors together with the pro forma blank detail
specification.
The SSMB series connectors with characteristic impedance 50 Ω are one kind of low power
miniature connectors with snap-on coupling mechanism and have the characteristics of light
weight, small size, convenient connection and excellent characteristics. This connector range
is suitable for the standard ranges of flexible and semi-rigid cables and is also available as a
PCB mounted version. The connectors are usable up to a frequency of 3 GHz.
It also prescribes mating face dimensions for grade 2 general purpose connectors,
dimensional detail of grade 0 standard test connectors, gauging information and tests
selected from IEC 61169-1 applicable to all detail specifications relating to SSMB series RF
connectors.
This specification indicates recommended performance characteristics to be considered when
writing a detail specification and it covers test schedules and inspection requirements for
assessment levels M and H.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 61169-1:1992, Radio-frequency connectors – Part 1: Generic specification – General
)
1
requirements and measuring methods
Amendment 1(1996)
Amendment 2 (1997)
3 Mating face and gauge information
3.1 Dimensions – General purpose connectors – Grade 2
3.1.1 Connector with socket-centre contact
Inch dimensions are original dimensions.
All non-dimensioned pictorial configurations are for reference purpose only.
)
1
There exists a consolidated edition 1.2 (1998) that comprises IEC 61169-1, its Amendment 1 and its
Amendment 2.
---------------------- Page: 7 ----------------------
– 6 – PAS 61169-19 © IEC:2009(E)
NOTE For dimensions and notes, see Table 1.
Figure 1 – Connector with socket- centre contact
Table 1 – Dimensions of connector with socket-centre contact
mm in
Ref.
min max min max
a 2,74 - 0,108 -
b - -
c - 1,34 - 0,053
d - 1,78 - 0,070
e 0,84 - 0,033 -
f 0,84 - 0,033 -
g 2,11 (nominal) 0,083 (nominal)
h 3,10 - 0,122 -
i 0,00 - 0,00 -
j 2,77 - 0,109 -
NOTE 1 Reference plane.
NOTE 2 The form and dimension of outer contact detent must meet electrical and mechanical
performance requirements.
NOTE 3 The diameters are chosen upon the assumption that the PTFE dielectric has a dielectric
constant of 2,02 to give an impedance of 50 Ω.
NOTE 4 Resilient contact may be closed or open entry, method of resilience is optional, provided that
when a pin of 0,36 mm ~0,38 mm (0,014 ~0,015 in) diameter is inserted, VSWR mating and endurance
performances are obtained.
---------------------- Page: 8 ----------------------
PAS 61169-19 © IEC:2009(E) – 7 –
3.1.2 Connector with pin-centre contact
NOTE For dimensions and notes, see Table 2.
Figure 2 – Connector with pin-centre contact
Table 2 – Dimensions of connector with pin-centre contact
mm in
Ref.
min max min max
k - 3,10 - 0,122
l 1,91 - 0,075 -
m - 0,84 - 0,033
n 0,00 - 0,000 -
p 2,11 (nominal) 0,083 (nominal)
q 1,37 - 0,054 -
r - 2,67 - 0,105
s 0,00 - 0,000 -
t 0,71 0,74 0,028 0,029
u
88º~92º 88º~92º
v 0,05 0,15 0,002 0,006
w - 2,75 - 0,108
x 1,91 - 0,075 -
y - 0,25 - 0,010
z 0,36 0,38 0,014 0,015
NOTE 1 Reference plane.
NOTE 2 The diameters are chosen upon the assumption that the PTFE dielectric has a dielectric
constant of 2,02 to give an impedance of 50 Ω.
---------------------- Page: 9 ----------------------
– 8 – PAS 61169-19 © IEC:2009(E)
3.2 Gauges
3.2.1 Gauge pins for socket-centre contact
NOTE For dimensions and notes, see Table 3.
Figure 3 – Gauge pins for socket-centre contact
Table 3 – Dimensions of gauge pins for socket-centre contact
Gauge B
Gauge A
Minimum material for measurement of retention
force
Maximum material for sizing purposes
Mass of gauge: 16 g ± 1 g
mm in mm in
Ref.
min max min max min max min max
a 0,381 0,384 0,015 0 0,015 1 0,353 0,356 0,013 9 0,014 0
b 1,70 1,80 0,067 0,071 1,70 1,80 0,067 0,071
Material: steel, polished, surface roughness: Ra=0,4 μm (16 μin) maximum.
3.2.2 Test procedure
The gauge A shall be inserted into the socket-centre contact three times with a minimum
depth of b. This is a sizing operation and should only be carried out when the socket-centre
contact is removed from the connector.
After this, the gauge B shall be inserted into socket-centre contact. The contact shall retain
the mass of the gauge in a vertical downward position. This test also shall be carried out on
connector when the socket-centre contact is not removed.
---------------------- Page: 10 ----------------------
PAS 61169-19 © IEC:2009(E) – 9 –
3.2.3 Gauge for outer contact of socket-centre contact
NOTE For dimensions and notes, see Table 4.
Figure 4 – Outer contact sizing and retention force gauges A and B
Table 4 – Dimensions of gauge for outer contact
Gauge B
Gauge A
(minimum material for measurement of
gauge retention force)
(maximum material for sizing purpose)
Ref.
Mass of gauge: 460 g ± 20 g
mm in mm in
min max min max min max min max
a 0,74 0,75 0,029 1 0,029 5 0,58 0,64 0,022 8 0,025 2
b 0,48 0,51 0,018 9 0,020 0 0,43 0,46 0,016 9 0,018 1
c 0,14 0,15 0,005 5 0,005 9 0,075 0,125 0,003 0 0,004 9
d - 0,08 - 0,003 1 - 0,08 - 0,003 1
e 0,08 0,18 0,003 1 0,007 1 0,08 0,18 0,003 1 0,007 1
f 0,2 0,4 0,007 9 0,015 7 0,2 0,4 0,007 9 0,015 7
g - 0,38 - 0,015 0 - 0,38 - 0,015 0
h 1,68 - 0,066 1 - 1,68 - 0,066 1 -
i 2,672 2,675 0,105 2 0,105 3 2,667 2,670 0,105 0 0,105 1
k 3,05 3,10 0,120 1 0,122 0 3,05 3,10 0,120 0 0,122 0
j 3,50 - 0,137 8 - 3,50 - 0,137 8 -
Material: steel, polished, surface roughness: Ra=0,4 µm (16 µin) maximum.
3.2.4 Test procedure
The gauge A shall be inserted into the outer contact of the socket-centre contact three times.
This is a sizing operation.
After this, the gauge B shall be inserted into the outer contact of the socket-centre contact.
The contact shall support the mass of the gauge in a vertical downward position.
NOTE Additional test: Following the sizing operation, the force necessary to insert gauge A into the outer contact
of the socket-centre contact shall be measured. When this test is required, the maximum permitted insertion force
is then specified and is smaller than 27 N.
---------------------- Page: 11 ----------------------
– 10 – PAS 61169-19 © IEC:2009(E)
3.3 Dimensions – Standard test connectors – Grade 0
3.3.1 Connector with socket-centre contact
NOTE For dimensions and notes, see Table 5.
Figure 5 – Connector with socket-centre contact
Table 5 – Dimensions of connector with socket-centre contact
mm in
Ref.
min max min max
a 2,740 2,840 0,107 9 0,111 8
b 2,464 2,514 0,097 0 0,099 0
c 1,295 1,340 0,051 0 0,052 8
d - 1,780 - 0,070 1
e 0,000 0,127 0,000 0 0,005 0
f 2,110(nominal) 0,0830(nominal)
g 0,000 0,127 0,000 0 0,005 0
h 0,840 0,942 0,033 1 0,037 1
i 3,100 3,150 0,122 0 0,124 0
k 2,770 - 0,109 1 -
NOTE 1 Reference plane.
NOTE 2 The diameters are chosen upon the assumption that the PTFE dielectric has a dielectric
constant of 2,02 to give an impedance of 50 Ω ± 0,5 Ω.
NOTE 3 Resilient contact may be closed or open entry, method of resilience optional, provided that
when a pin of 0,36 mm ~0,38 mm (0,014 in~0,015 in) diameter is inserted, VSWR mating and
endurance performances are obtained.
---------------------- Page: 12 ----------------------
PAS 61169-19 © IEC:2009(E) – 11 –
3.3.2 Connector with pin-centre contact
NOTE For dimensions and notes, see Table 6.
Figure 6 – Connector with pin-centre contact
Table 6 – Dimensions of connector with pin-centre contact
mm in
Ref.
min max min max
l 3,050 3,100 0,120 1 0,122 0
m 1,905 - 0,075 0 -
n 0,740 0,840 0,029 1 0,033 1
p 0,000 0,127 0,000 0 0,005 0
q 0,710 0,740 0,028 0 0,029 1
r 89º~91º 89º~91º
s 0,120 0,150 0,004 7 0,005 9
t 0,080 radius 0,003 0 radius
u
2,110(nominal) 0,0
...


Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.