IEC 62271-102:2001/COR4:2014
(Corrigendum)Corrigendum 4 - High-voltage switchgear and controlgear - Part 102: Alternanting current disconnectors and earthing switches
Corrigendum 4 - High-voltage switchgear and controlgear - Part 102: Alternanting current disconnectors and earthing switches
Corrigendum 4 - Appareillage à haute tension - Partie 102: Sectionneurs et sectionneurs de terre à courant alternatif
General Information
Relations
Standards Content (Sample)
IEC 62271-102 IEC 62271-102
(First edition – 2001) (Première édition – 2001)
High-voltage switchgear and controlgear – Appareillage à haute tension –
Part 102: Alternating current disconnectors and Partie 102: Sectionneurs et sectionneurs de terre
earthing switches à courant alternatif
CO RRI G E NDUM 4
4.103
...
This May Also Interest You
IEC TS 62271-319:2024 is applicable to alternating current circuit-breakers with intentional non-simultaneous pole operation designed for indoor or outdoor installations and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V. This document provides additional ratings and type tests to be conducted for this type of circuit-breaker and is intended to be used in conjunction with IEC 62271‑100:2021. Intentional non-simultaneous pole operation can be implemented by mechanical or electrical means and both methods are within the scope of this document.
- Technical specification75 pagesEnglish languagesale 15% off
IEC 62271-102:2018 applies to alternating current disconnectors and earthing switches, designed for indoor and outdoor installations for nominal voltages above 1 000 V and for service frequencies up to and including 60 Hz.
This second edition cancels and replaces the first edition published in 2001, Amendment 1:2011 and Amendment 2:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
new numbering according to IEC 17/1025/RQ to harmonize with ISO/IEC Directives, Part 2, and IEEE Std. C37.100.1;
clause numbering has been aligned with IEC 62271-1:2017;
the Scope has been extended to cover all indoor and outdoor installations. Consideration of switching devices having disconnecting and/or earthing switch functionalities, apart from other functions, are also covered by this document;
ratings have been moved from Annexes B, C and E to Clause 5; the order of the subclauses now corresponds to the order of subclauses in Clause 7;
new rating values for bus-transfer current and bus-transfer voltage have been assigned;
new class of mechanical endurance for earthing switches has been added (M1);
subclause "Rated values of electrical endurance for earthing switches" is now called "Classification of earthing switches for short-circuit making capability";
new subclause with ratings for ice-coating has been added;
new subclause with classification of bus-charging switching capability has been added;
new withstand requirements for interlocking devices have been added;
the way to comply with the requirements of the isolating distance of disconnectors has been modified;
design and construction requirements for position-indicating devices have been modified, aligning the requirements for position indication and signalling;
the value of the operating force has been changed;
the test procedures and validation criteria have been revised and modified where necessary;
requirements for applied voltage during single-phase test on non-simultaneous closing earthing switches have been changed;
non-verifiable requirements have been deleted;
a new subclause has been added for testing mechanical interlocking devices;
the high- and low-temperature test is mandatory if the temperature limits for the service conditions of the apparatus (defined by the manufacturer) are above +40 °C or below −5 °C, and a more detailed testing procedure is given;
the testing procedure to verify the proper functioning of the position-indicating device allows a more practicable testing for every technology used;
a new Annex B has been added with title: "Current-switching capability required of disconnectors and earthing switches";
a new Annex C has been added with title: "Tolerances on test quantities for type tests";
a new Annex E has been added with title: "Extension of validity of type tests".
- Standard657 pagesEnglish languagesale 15% off
- Standard222 pagesEnglish and French languagesale 15% off
- Standard444 pagesEnglish and French languagesale 15% off
- Standard5 pagesEnglish and French languagesale 15% off
IEC 62271-112:2021 is available as IEC 62271-112:2021 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 62271-112:2021 applies to AC high-speed earthing switches (hereinafter termed HSES) designed for indoor and outdoor installation and for operation at service frequencies of 50 Hz and 60 Hz on systems having rated voltages of 550 kV and above. HSESs described in this document are intended to extinguish the secondary arc remaining after clearing faults on transmission lines by the circuit-breakers. For more detailed information on HSESs, refer to Annex A. This second edition cancels and replaces the first edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: The document has been updated to the second edition of IEC 62271-1:2017.
- Standard84 pagesEnglish languagesale 15% off
- Standard54 pagesEnglish and French languagesale 15% off
IEC 62271-104:2020 is applicable to three-pole alternating current switches for rated voltages higher than 52 kV, having making and breaking current ratings, for indoor and outdoor installations, and for rated frequencies up to and including 60 Hz.
This third edition replaces and cancels the second edition published in 2015. It constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- new numbering, following IEC 62271-1:2017.
- Standard108 pagesEnglish and French languagesale 15% off
IEC 62271-104:2015 is applicable to three-pole alternating current switches for rated voltages higher than 52 kV, having making and breaking current ratings, for indoor and outdoor installations, and for rated frequencies up to and including 60 Hz. This standard is also applicable to the operating devices of these switches and to their auxiliary equipment. This second edition replaces and cancels the first edition published in 2009 and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- the title was changed such that the voltage range now is >52 kV instead of ≥52 kV;
- the references have been updated;
- the comments in 17A/1063/RVC have been addressed.
This publication is to be read in conjunction with IEC 62271-1:2007, IEC 62271-100:2008, IEC 62271-102:2001 and IEC 62271-110:2012.
- Standard102 pagesEnglish and French languagesale 15% off
IEC 62271-4:2013 applies to the procedures for handling of SF6 during installation, commissioning, normal and abnormal operations, disposal at the end of life of high voltage switchgear and controlgear. This first edition cancels and replaces the first edition of IEC/TR 62271-303 published in 2008. This first edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the description of the potential effects on health of SF6 by products (former Annex D of IEC/TR 62271-303:2008) has been replaced by the calculation methods for evaluating of the potential effects on health of SF6 by products (see Annex H);
b) information about cryogenic reclaim of SF6. Have been added (see Annex I);
c) handling procedures for the most popular SF6 mixtures have been added (see Annex J).
- Standard157 pagesEnglish and French languagesale 15% off
IEC 62271-112:2013 applies to a.c. high-speed earthing switches designed for indoor and outdoor installation and for operation at service frequencies of 50 Hz and 60 Hz on systems having voltages of 550 kV and above. High-speed earthing switches described in this standard are intended to extinguish the secondary arc remaining after clearing faults on transmission lines by the circuit-breakers.
This publication is to be read in conjunction with IEC 62271-1:2007.
- Standard52 pagesEnglish and French languagesale 15% off
Applies to alternating current disconnectors and earthing switches, designed for indoor and outdoor enclosed and open terminal installations for voltages above 1 000 V and for service frequencies up to and including 60 Hz. It also applies to the operating devices of these disconnectors and earthing switches and their auxiliary equipment. Additional requirements for disconnectors and earthing switches in enclosed switchgear and controlgear are given in IEC 60298, IEC 60466 and IEC 60517. Note: Disconnectors in which the fuse forms an integral part are not covered by this standard. This first edition cancels and replaces the third edition of IEC 60129 published in 1984, amendment 1 (1992) and amendment 2 (1996) and constitutes a technical revision. In addition, it replaces IEC 61128, IEC 61129 and IEC 61259, which are hereby withdrawn and cancelled. This bilingual version (2003-07) replaces the English version. The contents of the corrigenda of April 2002, May 2003, February 2005 and June 2014 have been included in this copy.
- Standard10 pagesEnglish languagesale 15% off
- Standard10 pagesEnglish languagesale 15% off
- Standard90 pagesEnglish languagesale 15% off
- Standard187 pagesEnglish and French languagesale 15% off
- Standard201 pagesEnglish and French languagesale 15% off
- Standard221 pagesEnglish and French languagesale 15% off
- Standard22 pagesEnglish and French languagesale 15% off
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.