IEC 61810-1:2015/ISH1:2023
(Main)Interpretation Sheet 1 - Electromechanical elementary relays - Part 1: General and safety requirements
Interpretation Sheet 1 - Electromechanical elementary relays - Part 1: General and safety requirements
General Information
Relations
Standards Content (Sample)
© IEC 2023
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
IEC 61810-1
Edition 4.0 2015-02
ELECTROMECHANICAL ELEMENTARY RELAYS –
Part 1: General and safety requirements
INTERPRETATION SHEET 1
This interpretation sheet has been prepared by IEC technical committee 94: All-or-nothing
electrical relays.
The text of this interpretation sheet is based on the following documents:
DISH Report on voting
94/785/DISH 94/806/RVDISH
Full information on the voting for the approval of this interpretation sheet can be found in the
report on voting indicated in the above table.
___________
Interpretation of Subclause 11.4: Final dielectric strength
Question: What dielectric strength values apply in case of functional insulation for contact
gaps?
Interpretation: Micro-disconnection is part of the functional insulation, whenever a reference
is given within this standard to functional insulation – only micro-disconnection requirements
are applicable for the contact gap within the contact – see ‘Figure A.2 of IEC 61810-1’ – contact
[number 2]
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.