IEC 61169-1:1992/AMD2:1997
(Amendment)Amendment 2 - Radio-frequency connectors - Part 1: Generic specification - General requirements and measuring methods
Amendment 2 - Radio-frequency connectors - Part 1: Generic specification - General requirements and measuring methods
Amendement 2 - Connecteurs pour fréquences radioélectriques - Partie 1: Spécification générique - Prescriptions générales et méthodes de mesure
General Information
Relations
Standards Content (Sample)
NORME
CEI
INTERNATIONALE
IEC
61169-1
INTERNATIONAL
QC 220000
STANDARD
AMENDEMENT 2
AMENDMENT 2
1997-04
Amendement 2
Connecteurs pour fréquences radioélectriques –
Partie 1:
Spécification générique –
Prescriptions générales et méthodes de mesure
Amendment 2
Radio-frequency connectors –
Part 1:
Generic specification –
General requirements and measuring methods
IEC 1997 Droits de reproduction réservés Copyright - all rights reserved
International Electrotechnical Commission 3, rue de Varembé Geneva, Switzerland
Telefax: +41 22 919 0300 e-mail: inmail@iec.ch IEC web site http: //www.iec.ch
CODE PRIX
Commission Electrotechnique Internationale
PRICE CODE E
International Electrotechnical Commission
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 61169-1 amend. 2 © CEI:1997
AVANT-PROPOS
Le présent amendement a été établi par le sous-comité 46D: Connecteurs pour fréquences
radioélectriques, du comité d’études 46 de la CEI: Câbles, fils, guides d’ondes, connecteurs et
accessoires pour communications et signalisation.
Le texte de cet amendement est issu des documents suivants:
FDIS Rapport de vote
46D/279/FDIS 46D/296/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cet amendement.
________
Page 150
Ajouter, après le paragraphe 10.3.2.3, le nouveau paragraphe suivant:
10.3.3 Programme d’essai et exigences de contrôle pour la procédure du prélèvement fixe
Tableau 1 – Procédure lot par lot – Essais d’acceptation: groupes A1 et B1
Méthode
Niveau d’assurance M (haut) Niveau d’assurance H (bas)
d’essai
de la CEI
61169-1
Test NQA Périodi- Test NQA Périodi-
QC 220000
NC NC
requis % cité requis % cité
Paragraphe
Groupe A1
Examen visuel
9.1.2 a 11 1,0 a S3 1,5
Groupe B1
Dimensions extérieures
9.1.3.1 a S4 0,40 a S3 0,40
Compatibilité mécanique
9.1.3.3 a 11 1,0 a S3 1,5
Accouplement et désaccouplement
9.3.6 a S4 0,40 a S3 1,5
Lot Lot
Rétention du calibre
9.3.4 ia 11 1,0 ia S3 1,5
(contacts élastiques)
par par
Etanchéité sans herméticité
9.4.5.1 ia 11 0,65 ia S3 1,0
Etanchéité avec herméticité
9.4.5.2 ia 11 0,015 ia S3 0,025
lot lot
Tension de tenue
9.2.6 a S4 0,40 a 11 4,0
d)
Soudabilité pièces détachées
9.3.2.1.1 ia S4 0,40 ia S3 4,0
Résistance d’isolement
9.2.5 a S4 0,40 a S3 4,0
Efficacité du fil des trous de
TBD ia S4 0,40 ia S3 4,0
sécurité
a applicable
ia test requis (si techniquement applicable)
NC niveau de contrôle
NQA niveau de qualité acceptable
d)
essais destructifs. Les spécimens ne doivent pas être remis en stock.
61169-1 Amend. 2 © IEC:1997 – 3 –
FOREWORD
This amendment has been prepared by the subcommittee 46D: RF connectors, of IEC
technical committee 46: Cables, wires, waveguides, RF connectors, and accessories for
communication and signalling.
The text of this amendment is based on the following documents:
FDIS Report on voting
46D/279/FDIS 46D/296/RVD
Full information on the voting for the approval of this amendment can be found in the report on
voting indicated in the above table.
________
Page 151
Add, after subclause 10.3.2.3, the following new subclause
10.3.3 Test schedules and inspection requirements for alternative fixed-quantity sample procedures
Table 1 – Lot-by-lot procedure – Acceptance tests: groups A1 and B1
Test
Assessment level M (higher) Assessment level H (lower)
method
of IEC
61169-1
Test AQL Period Test AQL Period
QC 220000
IL IL
required % required %
Subclause
Group A1
Visual inspection
9.1.2 a 11 1,0 a S3 1,5
Group B1
Outline dimensions
9.1.3.1 a S4 0,40 a S3 0,40
Mechanical compatibility
9.1.3.3 a 11 1,0 a S3 1,5
Engagement and separation
9.3.6 a S4 0,40 a S3 1,5
Lot Lot
Gauge retention force
9.3.4 ia 11 1,0 ia S3 1,5
(resilient contacts)
by by
Scaling, non-hermetic
9.4.5.1 ia 11 0,65 ia S3 1,0
Scaling, hermetic
9.4.5.2 ia 11 0,015 ia S3 0,025
lot lot
Voltage proof
9.2.6 a S4 0,40 a 11 4,0
d)
Solderability piece-parts
9.3.2.1.1 ia S4 0,40 ia S3 4,0
Insulation resistance
9.2.5 a S4 0,40 a S3 4,0
Effectiveness of safety wire locking
TBD ia S4 0,40 ia S3 4,0
d)
holes; piece-parts
a applicable
ia test required (if technically applicable)
IL inspection level
AQL acceptable quality level
d)
destructive tests – specimens shall not be returned to stock.
– 4 – 61169-1 amend. 2 © CEI:1997
Tableau 2 – Procédure de prélèvement fixe – Séquence initiale d’essais groupe 0
Méthode
Niveau d’assurance M (haut) Niveau d’assurance H (bas)
d’essai
de la CEI
61169-1
Test Nombre Test Nombre
QC 220000
requis d’échantillons requis d’échantillons
Paragraphe
Groupe 0
Examen visuel
9.1.2 a a
Dimensions extérieures
9.1.3.1 a a
Compatibilité mécanique
9.1.3.3 a a
Accouplement et désaccouplement
9.3.6 a a
ia ia
Rétention du calibre
9.3.4
36 minimum 18 minimum
(contacts élastiques)
ia
ia
Etanchéité sans herméticité
9.4.5.1
ia
ia
Etanchéité avec herméticité
9.4.5.2
a
a
Tension de tenue
9.2.6
ia
d)
ia
Soudabilité pièces détachées
9.3.2.1.1
a
Résistance d’isolement a
9.2.5
a applicable
ia test requis (si techniquement applicable)
d)
essais destructifs. Les spécimens ne doivent pas être remis en stock
61169-1 Amend. 2 © IEC:1997 – 5 –
Table 2 – Fixed quantity sample procedure – Initial QA test sequence: group 0
Test
Assessment level M (higher) Assessment level H (lower)
method
of IEC
61169-1
Test Number Test Number
QC 220000
required of specimens required of specimens
Subclause
Group 0
Visual inspection
9.1.2 a a
Outline dimensions
9.1.3.1 a a
Mechanical compatibility
9.1.3.3 a a
Engagement and separation
9.3.6 a a
ia ia
Gauge retention force
9.3.4
36 minimum 18 minim
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.