IEC 61810-1
(Second edition – 2003)
Electromechanical elementary relays –

Part 1: General and safety requirements

CORRIGENDUM 1
Page 6
2 Normative references
Replace the existing reference concerning IEC 60038 by the following:
IEC 60038:1983, IEC standard voltages
Amendment 1 (1994)
Amendment 2 (1997)
Page 27
10.3 Dielectric strength
Replace the existing first paragraph by the following:

The insulation is subjected to a voltage of substantially sine wave form, having a frequency of
50 Hz or 60 Hz, or a DC voltage. The test voltage shall be raised uniformly from 0 V to the
value prescribed in Table 9 or Table 10 within not more than 5 s and held at that value for
60 s without flashover. A current of not more than 3 mA is permitted.

Page 32
12.3 Release (monostable relays)
...

Questions, Comments and Discussion