Plastics piping systems for renovation of underground gas supply networks — Part 3: Lining with close-fit pipes

ISO 11299-3:2011, in conjunction with ISO 11299-1, specifies requirements and test methods for close-fit lining systems intended to be used for the renovation of gas supply networks. ISO 11299-3:2011 is applicable to polyethylene (PE) pipes for both independent and interactive pressure pipe liners as well as associated fittings and joints for the construction of the lining system.

Systèmes de canalisations en plastique pour la rénovation des réseaux de gaz enterrés — Partie 3: Tubage par tuyau continu sans espace annulaire

L'ISO 11299-3:2011, conjointement à l'ISO 11299-1, spécifie les exigences et les méthodes d'essai pour les systèmes de tubages par tuyau continu sans espace annulaire utilisés pour la rénovation des réseaux de gaz. L'ISO 11299-3:2011 s'applique aux tuyaux en polyéthylène (PE) à la fois pour les tubages autostructurants et les tubages nécessitant le maintien de l'enveloppe, ainsi qu'aux raccords associés et aux assemblages pour la construction du système de rénovation.

General Information

Status
Withdrawn
Publication Date
11-Sep-2011
Withdrawal Date
11-Sep-2011
Current Stage
9599 - Withdrawal of International Standard
Completion Date
26-Oct-2018
Ref Project

Relations

Buy Standard

Standard
ISO 11299-3:2011
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 11299-3:2011 - Plastics piping systems for renovation of underground gas supply networks
English language
13 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 11299-3:2011 - Systemes de canalisations en plastique pour la rénovation des réseaux de gaz enterrés
French language
14 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

МЕЖДУНАРОДНЫЙ ISO
СТАНДАРТ 11299-3
Первое издание
2011-09-15


Пластмассовые трубопроводы для
обновления подземных сетей
газоснабжения.
Часть 3.
Обкладка плотно прилегающими
трубами
Plastics piping systems for renovation of underground gas supply
networks —
Part 3 : Lining with closed-fit pipes




Ответственность за подготовку русской версии несёт GOST R
(Российская Федерация) в соответствии со статьёй 18.1 Устава ISO
Ссылочный номер
ISO 11299-3:2011R)
©
ISO 2011

---------------------- Page: 1 ----------------------
ISO 11299-3:2011(R)

ДОКУМЕНТ ЗАЩИЩЕН АВТОРСКИМ ПРАВОМ


© ISO 2011
Все права сохраняются. Если не задано иначе, никакую часть настоящей публикации нельзя копировать или использовать в
какой-либо форме или каким-либо электронным или механическим способом, включая фотокопии и микрофильмы, без
предварительного письменного согласия офиса ISO по адресу, указанному ниже, или членов ISO в стране регистрации
пребывания.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Опубликовано в Швейцарии

ii © ISO 2011 – Все права сохраняются

---------------------- Page: 2 ----------------------
ISO 11299-3:2011(R)
Содержание Страница
Предисловие .iv
Введение .v
1  Область применения .1
2  Нормативные ссылки .1
3  Термины и определения .1
3.1  Общие положения .2
3.2  Методы .2
3.3  Характеристики .2
3.4  Материалы .2
3.5  Этапы создания изделия .2
3.6  Условия эксплуатации.2
3.7  Соединения.3
4  Условные обозначения и аббревиатуры.3
4.1  Условные обозначения .3
4.2  Аббревиатуры.4
5  Трубы на этапе “M” .4
5.1  Материалы .4
5.2  Общие характеристики .4
5.3  Характеристики материалов .5
5.4  Геометрические характеристики .5
5.5  Механические характеристики.5
5.6  Физические характеристики.5
5.7  Соединение.5
5.8  Маркировка .5
6  Фитинги на этапе “M”.6
7  Вспомогательные компоненты .6
8  Соответствие установленной системы обкладки на этапе “I” .6
8.1  Материалы .6
8.2  Общие характеристики .6
8.3  Характеристики материала.6
8.5  Механические характеристики.7
8.6  Физические характеристики.9
8.7  Дополнительные характеристики.9
8.8  Отбор образцов .9
9  Практика монтажа.9
9.1  Подготовительная работа .9
9.2  Хранение, перемещение и транспортировка труб и фитингов .9
9.3  Оборудование .10
9.4  Внедрение.11
9.5  Испытания и контроль, связанные с технологией процесса .12
Приложение А (нормативное) Сфальцованная на заводе термореверсированная
полиэтиленовая (PE) труба. Определение способности к восстановлению формы.13
Библиография.15

© ISO 2011 – Все права сохраняются iii

---------------------- Page: 3 ----------------------
ISO 11299-3:2011(R)
Предисловие
Международная организация по стандартизации (ISO) является всемирной федерацией,
объединяющей национальные органы по стандартизации (комитеты-члены ISO). Разработка
международных стандартов, как правило, ведется в технических комитетах ISO. Каждый комитет-член,
заинтересованной в разработке теме, ради которой был образован данный технический комитет,
имеет право быть представленным в этом комитете. Международные организации, правительственные
и неправительственные, поддерживающие связь с ISO, также принимают участие в ее работе. ISO
сотрудничает с Международной электротехнической комиссией (IEC) по всем вопросам
стандартизации в области электротехники.
Международные стандарты разрабатываются в соответствии с правилами, приведенными в Части 2
Директив ISO/IEC.
Основное назначение технических комитетов заключается в разработке международных стандартов.
Проекты международных стандартов, принятые техническими комитетами, рассылаются комитетам-
членам на голосование. Для опубликования международного стандарта требуется собрать не менее
75 % положительных голосов комитетов-членов, принявших участие в голосовании.
Обращается внимание на вероятность того, что некоторые элементы настоящего документа могут
быть предметов патентных прав. ISO не несет ответственность за идентификацию части или всех
подобных прав.
ISO 11299-3 разработан Техническим комитетом ISO/TC 138, Трубы, фитинги и вентили из
пластмасс для транспортировки жидкостей.
ISO 11299 состоит из следующих частей, имеющих общий заголовок, Системы пластмассовых
трубопроводов для обновления подземных сетей газоснабжения:
⎯ Часть 1. Общие положения
⎯ Часть 3. Обкладка плотно прилегающими трубами
iv © ISO 2011 – Все права сохраняются

---------------------- Page: 4 ----------------------
ISO 11299-3:2011(R)
Введение
Настоящая часть ISO 11299 представляет собой системный стандарт на системы пластмассовых
трубопроводов из различных материалов, используемые для обновления существующих
трубопроводов в установленной области применения. Системные стандарты на обновление
распространяются на нижеследующее:
⎯ системы пластмассовых трубопроводов для обновления подземных безнапорных дренажных и
канализационных сетей;
⎯ системы пластмассовых трубопроводов для обновления подземных дренажных и
канализационных сетей под давлением;
⎯ системы пластмассовых трубопроводов для обновления подземных водопроводных сетей;
⎯ системы пластмассовых трубопроводов для обновления подземных сетей газоснабжения (данное
применение).
Эти системные стандарты отличаются от стандартов на обычные системы пластмассовых труб, т.к.
устанавливают требования к определенным характеристикам по состоянию на момент монтажа, после
соответствующей обработки на месте. Настоящий документ дополняет требования к компонентам
систем на стадии производства.
Каждый из системных стандартов включает Часть 1. Общие положения и все применимые части,
относящиеся к семейству методов обновления, которые приводятся ниже:
⎯ Часть 2. Обкладка сплошными трубами
⎯ Часть 3. Обкладка плотно прилегающими трубами
⎯ Часть 4. Обкладка посредством горячей вулканизации труб на месте
⎯ Часть 6. Обкладка покрытые клеем шланги
Требования к любому установленному семейству методов обновления приводятся в настоящей части
ISO 11299 и применимы вместе с другой соответствующей частью. Например, как ISO 11299-1, так и
настоящая часть ISO 11299, устанавливают требования, касающиеся обкладки плотно прилегающими
трубами. Относительно дополнительной информации, см. ISO 11295. Не все семейства методов могут
относиться к каждой области применения, что отражено в номерах частей, включенных в каждый
системный стандарт.
Для удобства проведения прямого сравнения между семействами методов обновления была
разработана совместимая структура заголовков для всех частей ISO 11299.
На Рисунке 1 приведена структура общей части и разделов и зависимость между ISO 11299 и
системными стандартами на прочие области применения.
© ISO 2011 – Все права сохраняются v

---------------------- Page: 5 ----------------------
ISO 11299-3:2011(R)

Рисунок 1 — Формат для системных стандартов на обновление
vi © ISO 2011 – Все права сохраняются

---------------------- Page: 6 ----------------------
МЕЖДУНАРОДНЫЙ СТАНДАРТ ISO 11299-3:2011(R)

Пластмассовые трубопроводы для обновления подземных
сетей газоснабжения.
Часть 3.
Обкладка плотно прилегающими трубами
1 Область применения
Настоящая часть ISO 11299, вместе с ISO 11299-1, устанавливает методы испытаний и требования к
системам обкладки плотно прилегающими трубами, предназначенными для использования с целью
обновления сетей газоснабжения.
Стандарт распространяется на полиэтиленовые (PE) трубы, как на независимые, так и интерактивные
трубные обкладки под давлением, а также на соответствующие фитинги и соединения для конструкции
обкладочной системы.
2 Нормативные ссылки
Нижеследующие ссылочные документы обязательны для применения настоящего документа. В
отношении датированных ссылок действительны только указанные издания. В отношении
недатированных ссылок применимо последнее издание упоминаемого документа, включая любые к
нему изменения.
ISO 3126, Трубы пластмассовые. Пластмассовые компоненты. Определение размеров
ISO 4437:2007, Трубопроводы полиэтиленовые (РЕ) заглубленные для подачи газообразного
топлива. Метрическая серия. Технические условия
ISO 8085-3, Фитинги полиэтиленовые для полиэтиленовых труб, используемых для подачи
газообразного топлива. Метрическая серия. Технические условия. Часть 3. Фитинги,
присоединяемые электросваркой
ISO 11299-1:2011, Системы пластмассовых трубопроводов для обновления подземных сетей
газоснабжения. Часть 1. Общие положения
ISO 12176-1, Трубы и фитинги пластмассовые. Оборудование для соединения плавлением
полиэтиленовых систем. Часть 1. Стыковое соединение плавлением
ISO 12176-2, Трубы и фитинги пластмассовые. Оборудование для соединения плавлением
полиэтиленовых систем. Часть 2. Электроплавление
3 Термины и определения
Исходя из назначения настоящего документа, применимы термины и определения, приведенные в
ISO 11299-1 и нижеследующее.
© ISO 2011 – Все права сохраняются 1

---------------------- Page: 7 ----------------------
ISO 11299-3:2011(R)
3.1 Общие положения
3.1.1
плотное прилегание
close fit
ситуация снаружи установленной прокладки относительно внутренней стороны существующего
трубопровода, которая может быть либо посадкой с натягом, или включать небольшой окружной зазор
в результате только усадки и допусков
3.1.2
плотно прилегающая труба
close-fit pipe
сплошная обкладочная труба из термопластичного материала, которая имеет восстановленную
первоначальную форму, или каким-либо способом была развальцована после введения с целью
достижения точной посадки с существующим трубопроводом
3.2 Методы
Не применимы дополнительные определения.
3.3 Характеристики
3.3.1
максимальный средний наружный диаметр
d
em,max
maximum mean outside diameter
d
em,max
максимальное значение среднего наружного диаметра, установленное для заданного номинального
размера
3.4 Материалы
Не применимы дополнительные определения.
3.5 Этапы создания изделия
Не применимы дополнительные определения.
3.6 Условия эксплуатации
3.6.1
максимальное рабочее давление
МОР
maximum operating pressure
MOP
максимальное эффективное давление текучей среды в системе трубопроводов, которое допустимо
для непрерывного использования
5 2
ПРИМЕЧАНИЕ 1 MOP выражают в барах, где 1 бар = 0,1 МПа = 10 Па; 1 МПа = 1 Н/мм .
ПРИМЕЧАНИЕ 2 С учетом физических и механических характеристик компонентов системы трубопроводов.
ПРИМЕЧАНИЕ 3 Вычисляют с применением следующего уравнения:
20×()MRS
MOP=
C×−()SDR 1
2 © ISO 2011 – Все права сохраняются

---------------------- Page: 8 ----------------------
ISO 11299-3:2011(R)
3.7 Соединения
3.7.1
соединение, полученное электроплавлением
electrofusion joint
соединение между PE раструбом или опорой электроплавленного фитинга и трубой или фитингом с
втулочными концами, полученное путем нагревания электроплавленных фитингов с помощью
теплового действия тока нагревательного элемента, введенного в их соединяемые поверхности,
которое приводит к оплавлению материала, прилагающего к ним, и расплавлению поверхностей трубы
и фитинга
3.7.2
стыковое соединение плавлением
butt fusion joint
соединение, полученное путем нагревания плоских концов сопряженных поверхностей посредством
прижатия их к плоской нагревательной панели до тех пор, пока PE материал не достигнет температуры
плавления, быстрого удаления этой панели и го контакта двух размягченных концов друг к другу
3.7.3
механическое соединение
mechanical joint
соединение, полученное сборкой PE трубы с еще одной PE трубой или любым другим элементом
трубопроводной системы, который обычно включает компрессионную часть, с целью обеспечения
целостности при воздействии давления, герметичности и стойкости к торцевым нагрузкам
ПРИМЕЧАНИЕ Несущая втулка, помещенная в канал трубы, используется для обеспечения постоянной опоры
для РЕ трубы, предотвращая ползучесть стенок трубы при радиальных сжимающих усилиях.
3.7.4
совместимость при оплавлении
fusion compatibility
способность двух однородных или разнородных PE материалов сплавляться, образуя соединение,
которое соответствует требованиям к эксплуатации настоящей части ISO 11299
4 Условные обозначения и аббревиатуры
4.1 Условные обозначения
C общий рабочий (расчетный) коэффициент
d наружный диаметр (в любой точке)
e
d максимальный средний наружный диаметр
em,max
d минимальный средний наружный диаметр
em,min
d начальный окружной наружный диаметр трубы (перед обработкой для ввода)
manuf
e максимальная средняя толщина стенок
m,max
T температура, при которой были получены результаты испытаний на длительную прочность
t время до появления утечки в трубе
t допуск на толщину стенок
y
σ расчетное напряжение
s
© ISO 2011 – Все права сохраняются 3

---------------------- Page: 9 ----------------------
ISO 11299-3:2011(R)
4.2 Аббревиатуры
LPL нижний доверительный предел прогнозируемой гидростатической прочности
MFR удельный массовый расход расплава
MOP максимальное рабочее давление
MRS минимальная требуемая прочность
PE полиэтилен
R ряд предпочтительных чисел, соответствующий ряду Ренара
SDR стандартное размерное отношение
5 Трубы на этапе “M”
5.1 Материалы
5.1.1 Свежий материал
Используемый свежий материал должен соответствовать одному из наименований PE соединений,
указанных в Таблице 1.
Таблица 1 –– Обозначения PE соединений
Классификация по MRS
Обозначение
МПа
PE 80 8
PE 100 10
Соединение должно соответствовать ISO 4437.
5.1.2 Переработанный и повторно используемый материал
В соответствии с ISO 4437 может использоваться собственный переработанный материал
изготовителя, при условии, что он получен из того же самого соединения, которое применялось для
соответствующего производства.
Переработанный материал, полученный из внешних источников, и повторно используемый материал,
не должны использоваться.
5.2 Общие характеристики
5.2.1 Внешний вид
При осмотре без помощи средств увеличения внутренние и внешние поверхности трубы должны быть
гладкими, чистыми и свободными от царапин, каверн и других дефектов, которые могут предотвратить
соответствие настоящей части ISO 11299.
4 © ISO 2011 – Все права сохраняются

---------------------- Page: 10 ----------------------
ISO 11299-3:2011(R)
5.2.2 Цвет
Трубы должны быть желтого или оранжевого цвета, или черного с желтыми или оранжевыми
идентификационными полосами.
5.3 Характеристики материалов
Материал, из которого изготавливают трубы, должен соответствовать требованиям, установленным в
Таблице 1 ISO 4437:2007.
5.4 Геометрические характеристики
Диаметры труб, толщина их стенок и форма на этапе “M” зависят от специфического метода
го прилегания обкладки. Размеры этапа “M”, необходимые для получения размеров на этапе “I” (см.
8.4), устанавливает изготовитель, вместе с допусками.
ПРИМЕЧАНИЕ В случае сфальцованных на заводе труб могут отмечаться изменения в толщине стенок в
одном поперечном сечении. Это допустимо, если данная сфальцованная труба имеет свойства, при которых
может быть получена толщины стенок в соответствии с 8.4 после завершения установки.
5.5 Механические характеристики
При испытании в соответствии с методом, приведенным в Таблице 2, труба должна соответствовать
требованиям данной таблицы.
Таблица 2 — Механические характеристики труб
Параметры, подлежащие проверке
Метод
Характеристика Требование
испытаний
Параметры Значение
Удлинение при разрыве
a
ISO 4437
Гидростатическая прочность (80 °C, 165 ч)
a
Труба подлежит реверсированию в случае фальцевания на заводе.
5.6 Физические характеристики
Физические характеристики должны соответствовать приведенным в ISO 4437. В случае
сфальцованных на заводе термореверсированных труб данная труба дополнительно должна отвечать
требованию к способности к восстановлению формы, которое пр
...

INTERNATIONAL  ISO
STANDARD 11299-3
First edition
2011-09-15
Plastics piping systems for renovation of
underground gas supply networks
Part 3:
Lining with close-fit pipes
Systèmes de canalisations en plastique pour la rénovation des réseaux de
gaz enterrés — Partie 3: Tubage par tuyau continu sans espace annulaire
Reference number
ISO 11299-3:2011(E)
©
 ISO 2011

---------------------- Page: 1 ----------------------
ISO 11299-3:2011(E)
COPYRIGHT PROTECTED DOCUMENT
©  ISO 2011
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO’s
member body in the country of the requester.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
ii © ISO 2011 – All rights reserved

---------------------- Page: 2 ----------------------
ISO 11299-3:2011(E)
Contents Page
Foreword .iv
Introduction . v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
3.1 General . 1
3.2 Techniques . 2
3.3 Characteristics . 2
3.4 Materials . 2
3.5 Product stages . 2
3.6 Service conditions . 2
3.7 Joints . 2
4 Symbols and abbreviated terms . 3
4.1 Symbols . 3
4.2 Abbreviated terms . 3
5 Pipes at the “M” stage . 3
5.1 Materials . 3
5.2 General characteristics . 4
5.3 Material characteristics . 4
5.4 Geometric characteristics . 4
5.5 Mechanical characteristics . 4
5.6 Physical characteristics . 5
5.7 Jointing . 5
5.8 Marking . 5
6 Fittings at the “M” stage . 5
7 Ancillary components . 5
8 Fitness for purpose of the installed lining system at the “I” stage . 5
8.1 Materials . 5
8.2 General characteristics . 5
8.3 Material characteristics . 5
8.4 Geometric characteristics . 6
8.5 Mechanical characteristics . 6
8.6 Physical characteristics . 7
8.7 Additional characteristics . 7
8.8 Sampling . 8
9 Installation practice . 8
9.1 Preparatory work . 8
9.2 Storage, handling and transport of pipes and fittings . 8
9.3 Equipment . 8
9.4 Installation . 9
9.5 Process-related inspection and testing .10
Annex A (normative) Factory-folded heat-reverted polyethylene (PE) pipe — Determination of memory
ability . 11
Bibliography .13
© ISO 2011 – All rights reserved  iii

---------------------- Page: 3 ----------------------
ISO 11299-3:2011(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 11299-3 was prepared by Technical Committee ISO/TC 138, Plastics pipes, fittings and valves for the
transport of fluids.
ISO 11299 consists of the following parts, under the general title Plastics piping systems for renovation of
underground gas supply networks:
—  Part 1: General
—  Part 3: Lining with close-fit pipes
iv © ISO 2011 – All rights reserved

---------------------- Page: 4 ----------------------
ISO 11299-3:2011(E)
Introduction
This part of ISO 11299 is part of a system standard for plastics piping systems of various materials used for the
renovation of existing pipelines in a specified application area. System standards for renovation deal with the
following applications:
—  plastics piping systems for renovation of underground non-pressure drainage and sewerage networks;
—  plastics piping systems for renovation of underground drainage and sewerage networks under pressure;
—  plastics piping systems for renovation of underground water supply networks;
—  plastics piping systems for renovation of underground gas supply networks (this application).
These system standards are distinguished from those for conventionally installed plastics piping systems
because they set requirements for certain characteristics in the as-installed condition, after site processing.
This is in addition to verification of characteristics of plastics piping systems as manufactured.
This system standard comprises a Part 1: General and all applicable parts relating to the renovation technique
family, from the following:
—  Part 2: Lining with continuous pipes
—  Part 3: Lining with close-fit pipes (this document)
—  Part 4: Lining with cured-in-place pipes
—  Part 6: Lining with adhesive-backed hoses
The requirements for any given renovation technique family are specified in this part of ISO 11299 and are
applied in conjunction with the relevant other part. For example, both ISO 11299-1 and this part of ISO 11299
specify the requirements relating to lining with close-fit pipes. For complementary information, see ISO 11295.
Not all technique families are pertinent to every area of application and this is reflected in the part numbers
included in each system standard.
A consistent structure of clause headings has been adopted for all parts of ISO 11299, in order to facilitate
direct comparisons across renovation technique families.
Figure 1 illustrates the common part and clause structure and the relationship between ISO 11299 and the
system standards for other application areas.
© ISO 2011 – All rights reserved  v

---------------------- Page: 5 ----------------------
ISO 11299-3:2011(E)
Figure 1 — Format of the renovation system standards
vi © ISO 2011 – All rights reserved

---------------------- Page: 6 ----------------------
INTERNATIONAL STANDARD ISO 11299-3:2011(E)
Plastics piping systems for renovation of underground gas
supply networks
Part 3:
Lining with close-fit pipes
1 Scope
This part of ISO 11299, in conjunction with ISO 11299-1, specifies requirements and test methods for close-fit
lining systems intended to be used for the renovation of gas supply networks.
It is applicable to polyethylene (PE) pipes for both independent and interactive pressure pipe liners as well as
associated fittings and joints for the construction of the lining system.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
ISO 3126, Plastics piping systems — Plastics components — Determination of dimensions
ISO 4437:2007, Buried polyethylene (PE) pipes for the supply of gaseous fuels — Metric series — Specifications
ISO 8085-3, Polyethylene fittings for use with polyethylene pipes for the supply of gaseous fuels — Metric
series — Specifications — Part 3: Electrofusion fittings
ISO 11299-1:2011, Plastics piping systems for renovation of underground gas supply networks — Part 1: General
ISO 12176-1, Plastics pipes and fittings — Equipment for fusion jointing polyethylene systems — Part 1: Butt fusion
ISO 12176-2,  Plastics pipes and fittings  — Equipment for fusion jointing polyethylene systems  — Part 2:
Electrofusion
3 Terms and definitions
For the purposes of this document, the terms, definitions, symbols and abbreviations given in ISO 11299-1 and
the following apply.
3.1 General
3.1.1
close fit
situation of the outside of the installed liner relative to the inside of the existing pipeline, which may either be an
interference fit or include a small annular gap resulting from shrinkage and tolerances only
3.1.2
close-fit pipe
continuous lining pipe of thermoplastic material reshaped or otherwise expanded after insertion to achieve a
close fit to the existing pipeline
© ISO 2011 – All rights reserved  1

---------------------- Page: 7 ----------------------
ISO 11299-3:2011(E)
3.2 Techniques
No additional definitions apply.
3.3 Characteristics
3.3.1
maximum mean outside diameter
d
em,max
maximum value of the mean outside diameter as specified for a given nominal size
3.4 Materials
No additional definitions apply.
3.5 Product stages
No additional definitions apply.
3.6 Service conditions
3.6.1
maximum operating pressure
MOP
maximum effective pressure of the fluid in the piping system which is allowed in continuous use
5 2
NOTE 1  MOP is expressed in bar, where 1 bar = 0,1 MPa = 10 Pa; 1 MPa = 1 N/mm.
NOTE 2  It takes into account the physical and the mechanical characteristics of the components of a piping system.
NOTE 3  It is calculated using the following equation:
20× MRS
( )
MOP =
C×(SDR−1)
3.7 Joints
3.7.1
electrofusion joint
joint between a PE socket or saddle electrofusion fitting and a pipe or fitting with spigotted ends, made by
heating the electrofusion fittings by the Joule effect of the heating element incorporated at their jointing
surfaces, causing the material adjacent to them to melt and pipe and fitting surfaces to fuse
3.7.2
butt fusion joint
joint made by heating the planed ends of matching surfaces by holding them against a flat heating plate until
the PE material reaches fusion temperature, quickly removing the heating plate and pushing the two softened
ends against one another
3.7.3
mechanical joint
joint made by assembling a PE pipe to another PE pipe, or any other element of the piping system that generally
includes a compression part, to provide for pressure integrity, leaktightness and resistance to end loads
NOTE  A support sleeve inserted into the pipe bore can be used to provide a permanent support for the PE pipe to
prevent creep in the pipe wall under radial compressive forces.
2 © ISO 2011 – All rights reserved

---------------------- Page: 8 ----------------------
ISO 11299-3:2011(E)
3.7.4
fusion compatibility
ability of two similar or dissimilar PE materials to be fused together to form a joint which conforms to the
performance requirements of this part of ISO 11299
4 Symbols and abbreviated terms
4.1 Symbols
C overall service (design) coefficient
d outside diameter (at any point)
e
d maximum mean outside diameter
em,max
d minimum mean outside diameter
em,min
d original circular outside diameter of the pipe (before processing for insertion)
manuf
e maximum mean wall thickness
m,max
T temperature at which stress rupture data have been determined
t time to occurrence of a leak in the pipe
t wall thickness tolerance
y
σ design stress
s
4.2 Abbreviated terms
LPL lower confidence limit of the predicted hydrostatic strength
MFR melt mass-flow rate
MOP maximum operating pressure
MRS minimum required strength
PE polyethylene
R series of preferred numbers, conforming to the Renard series
SDR standard dimension ratio
5 Pipes at the “M” stage
5.1 Materials
5.1.1 Virgin material
The virgin material used shall be in accordance with one of the PE compound designations given in Table 1.
© ISO 2011 – All rights reserved  3

---------------------- Page: 9 ----------------------
ISO 11299-3:2011(E)
Table 1 — PE compound designations
Classification by MRS
Designation
MPa
PE 80 8
PE 100 10
The compound shall conform to ISO 4437.
5.1.2 Reprocessable and recyclable material
In accordance with ISO 4437, the manufacturer’s own reprocessable material may be used, provided that it is
derived from the same compound as used for the relevant production.
Reprocessable material obtained from external sources and recyclable material shall not be used.
5.2 General characteristics
5.2.1 Appearance
When viewed without magnification, the internal and external surfaces of the pipe shall be smooth, clean and
free from scoring, cavities and other defects which would prevent conformity to this part of ISO 11299.
5.2.2 Colour
The pipes shall be yellow or orange, or black with yellow or orange identification stripes.
5.3 Material characteristics
The material from which the pipes are made shall conform to the requirements specified in Table 1 of
ISO 4437:2007.
5.4 Geometric characteristics
The pipe diameter, wall thickness and shape in the “M” stage depend on the specific close-fit lining technique.
“M” stage dimensions needed to obtain “I” stage dimensions (see 8.4) shall be declared, with their tolerances,
by the manufacturer.
NOTE  In the case of factory-folded pipes, variations in wall thickness in one cross-section can be present. This is
acceptable as long as the folded pipe has properties such that it can obtain a wall thicknes
...

NORME  ISO
INTERNATIONALE 11299-3
Première édition
2011-09-15
Systèmes de canalisations en plastique
pour la rénovation des réseaux de gaz
enterrés
Partie 3:
Tubage par tuyau continu sans espace
annulaire
Plastics piping systems for renovation of underground gas supply
networks — Part 3: Lining with close-fit pipes
Numéro de référence
ISO 11299-3:2011(F)
©
 ISO 2011

---------------------- Page: 1 ----------------------
ISO 11299-3:2011(F)
DOCUMENT PROTÉGÉ PAR COPYRIGHT
©  ISO 2011
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l’accord écrit
de l’ISO à l’adresse ci-après ou du comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 • CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
ii © ISO 2011 – Tous droits réservés

---------------------- Page: 2 ----------------------
ISO 11299-3:2011(F)
Sommaire Page
Avant-propos .iv
Introduction . v
1 Domaine d’application . 1
2 Références normatives . 1
3 Termes et définitions . 1
3.1 Généralités . 1
3.2 Techniques . 2
3.3 Géométrie . 2
3.4 Matières . 2
3.5 Stades des produits . 2
3.6 Conditions d’utilisation. 2
3.7 Assemblages . 2
4 Symboles et abréviations . 3
4.1 Symboles . 3
4.2 Abréviations . 3
5 Tuyaux au stade «M» . 4
5.1 Matières . 4
5.2 Caractéristiques générales . 4
5.3 Caractéristiques des matières . 4
5.4 Caractéristiques géométriques . 4
5.5 Caractéristiques mécaniques . 4
5.6 Caractéristiques physiques . 5
5.7 Assemblage . 5
5.8 Marquage . 5
6 Raccords au stade «M» . 5
7 Accessoires . 5
8 Aptitude à l’emploi du système de rénovation installé au stade «I» . 6
8.1 Matières . 6
8.2 Caractéristiques générales . 6
8.3 Caractéristiques des matières . 6
8.4 Caractéristiques géométriques . 6
8.5 Caractéristiques mécaniques . 7
8.6 Caractéristiques physiques . 8
8.7 Caractéristiques supplémentaires . 8
8.8 Échantillonnage . 8
9 Pratique d’installation . 8
9.1 Travaux préparatoires . 8
9.2 Stockage, manutention et transport . 8
9.3 Équipements . 9
9.4 Installation .10
9.5 Contrôle et essai relatifs au processus d’installation . 11
Annexe A (normative) Tuyau en polyéthylène (PE) rétabli à son état initial à chaud, plié en usine —
Détermination de la capacité de mémoire .12
Bibliographie .14
© ISO 2011 – Tous droits réservés  iii

---------------------- Page: 3 ----------------------
ISO 11299-3:2011(F)
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes nationaux de
normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est en général confiée aux
comités techniques de l’ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du comité
technique créé à cet effet. Les organisations internationales, gouvernementales et non gouvernementales,
en liaison avec l’ISO participent également aux travaux. L’ISO collabore étroitement avec la Commission
électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI, Partie 2.
La tâche principale des comités techniques est d’élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur publication
comme Normes internationales requiert l’approbation de 75 % au moins des comités membres votants.
L’attention est appelée sur le fait que certains des éléments du présent document peuvent faire l’objet de droits
de propriété intellectuelle ou de droits analogues. L’ISO ne saurait être tenue pour responsable de ne pas avoir
identifié de tels droits de propriété et averti de leur existence.
L’ISO 11299-3 a été élaborée par le comité technique ISO/TC 138, Tubes, raccords et robinetterie en matières
plastiques pour le transport des fluides.
L’ISO 11299 comprend les parties suivantes, présentées sous le titre général Systèmes de canalisations en
plastique pour la rénovation des réseaux de gaz enterrés:
—  Partie 1: Généralités
—  Partie 3: Tubage par tuyau continu sans espace annulaire
iv © ISO 2011 – Tous droits réservés

---------------------- Page: 4 ----------------------
ISO 11299-3:2011(F)
Introduction
La présente partie de l’ISO 11299 constitue une partie d’une Norme de Systèmes pour des systèmes de
canalisations en plastique à base de matériaux variés utilisés pour la rénovation de canalisations existantes
dans un domaine d’application spécifié. Les Normes de Systèmes relatives à la rénovation traitent des
applications suivantes:
—  systèmes de canalisations en plastique pour la rénovation des réseaux d’assainissement enterrés
sans pression;
—  systèmes de canalisations en plastique pour la rénovation des réseaux d’assainissement enterrés
sous pression;
—  systèmes de canalisations en plastique pour la rénovation des réseaux enterrés d’alimentation en eau;
—  systèmes de canalisations en plastique pour la rénovation des réseaux de gaz enterrés.
Ces Normes de Systèmes se distinguent des normes relatives aux systèmes de canalisations en plastique
installés traditionnellement du fait qu’elles établissent des exigences concernant certaines caractéristiques
liées aux conditions d’installation, après mise en œuvre sur le site. Cela s’ajoute aux exigences spécifiques
pour les composants du système de canalisations en plastique tels que fabriqués.
Chacune des Normes de Systèmes comprend une Partie 1 (Généralités) et toutes les parties applicables aux
familles de techniques de rénovation contenues dans la liste suivante:
—  Partie 2: Tubage par tuyau continu avec espace annulaire;
—  Partie 3: Tubage par tuyau continu sans espace annulaire;
—  Partie 4: Tubage continu par tubes polymérisés sur place;
—  Partie 6: Tubage par gaines souples revêtues d’un adhésif.
Les exigences applicables à toute famille de techniques de rénovation donnée sont indiquées dans la Partie 1,
appliquée conjointement à toute autre partie associée. Par exemple, l’ISO 11299-1 et la présente partie de
l’ISO 11299 spécifient les exigences se rapportant au tubage par tuyau continu sans espace annulaire. Pour toute
information complémentaire, voir l’ISO 11295. Toutes les familles de techniques ne sont pas applicables à chaque
domaine d’application et cela se reflète dans les numéros de parties compris dans chaque Norme de Système.
Une structure cohérente des titres des articles a été adoptée pour toutes les parties de l’ISO 11299 afin de
faciliter des comparaisons directes entre les différentes familles de techniques de rénovation.
La Figure 1 illustre la structure commune des parties et des articles et la relation entre l’ISO 11299 et les
Normes de Systèmes concernant d’autres domaines d’application.
© ISO 2011 – Tous droits réservés  v

---------------------- Page: 5 ----------------------
ISO 11299-3:2011(F)
Figure 1 — Présentation des Normes de Systèmes de rénovation
vi © ISO 2011 – Tous droits réservés

---------------------- Page: 6 ----------------------
NORME INTERNATIONALE ISO 11299-3:2011(F)
Systèmes de canalisations en plastique pour la rénovation des
réseaux de gaz enterrés
Partie 3:
Tubage par tuyau continu sans espace annulaire
1 Domaine d’application
La présente partie de l’ISO 11299, conjointement à l’ISO 11299-1, spécifie les exigences et les méthodes
d’essai pour les systèmes de tubages par tuyau continu sans espace annulaire utilisés pour la rénovation des
réseaux de gaz.
Elle s’applique aux tuyaux en polyéthylène (PE) à la fois pour les tubages autostructurants et les tubages
nécessitant le maintien de l’enveloppe, ainsi qu’aux raccords associés et aux assemblages pour la construction
du système de rénovation.
2 Références normatives
Les documents de référence suivants sont indispensables pour l’application du présent document. Pour les
références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière édition du
document de référence s’applique (y compris les éventuels amendements).
ISO 3126, Systèmes de canalisations en plastiques — Composants en plastiques — Détermination des dimensions
ISO 4437:2007, Canalisations enterrées en polyéthylène (PE) pour réseaux de distribution de combustibles
gazeux — Série métrique — Spécifications
ISO 8085-3, Raccord en polyéthylène pour utilisation avec des tubes en polyéthylène pour la distribution de
combustibles gazeux — Série métrique — Spécifications — Partie 3: Raccords électrosoudables
ISO 11299-1:2011, Systèmes de canalisations en plastique pour la rénovation des réseaux de gaz enterrés —
Partie 1: Généralités
ISO 12176-1, Tubes et raccords en matières plastiques — Appareillage pour l’assemblage par soudage des
systèmes en polyéthylène — Partie 1: Soudage bout à bout
ISO 12176-2, Tubes et raccords en matières plastiques — Appareillage pour l’assemblage par soudage des
systèmes en polyéthylène — Partie 2: Électrosoudage
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions donnés dans l’ISO 11299-1 ainsi que les
suivants s’appliquent.
3.1 Généralités
3.1.1
sans espace annulaire
situation de l’extérieur du tubage installé par rapport à l’intérieur de la canalisation existante, qui peut soit être
un contact avec interférence, soit inclure un petit espace annulaire dû uniquement au retrait et aux tolérances
© ISO 2011 – Tous droits réservés  1

---------------------- Page: 7 ----------------------
ISO 11299-3:2011(F)
3.1.2
tuyau continu sans espace annulaire
tuyau de rénovation continu en matière thermoplastique reformé, ou dilaté d’une autre manière après l’insertion,
assurant l’absence d’espace annulaire avec la canalisation existante
3.2 Techniques
Aucune définition supplémentaire ne s’applique.
3.3 Géométrie
3.3.1
diamètre extérieur moyen maximal
d
em,max
valeur maximale du diamètre extérieur moyen, spécifiée pour une dimension nominale donnée
3.4 Matières
Aucune définition supplémentaire ne s’applique.
3.5 Stades des produits
Aucune définition supplémentaire ne s’applique.
3.6 Conditions d’utilisation
3.6.1
pression maximale de service
MOP
pression effective maximale du fluide dans le système de canalisations, exprimée en bar, qui est admise en utilisation continue
5 2
NOTE 1  MOP est exprimé en bar, où 1 bar = 0,1 MPa = 10 Pa; 1 MPa = 1 N/mm.
NOTE 2  Elle tient compte des caractéristiques physiques et mécaniques des composants d’un système de canalisations.
NOTE 3  Elle est calculée en utilisant l’équation suivante:
20×MRS
MOP =
C×(SDR−1)
3.7 Assemblages
3.7.1
assemblage électrosoudable
assemblage entre un raccord à emboîture électrosoudable ou une selle électrosoudable en PE et un tuyau
ou un raccord à bouts mâles, réalisé en chauffant les raccords électrosoudables par effet Joule de l’élément
chauffant incorporé au niveau de leurs surfaces de raccordement, ce qui provoque la fusion du matériau/de la
matière adjacent(e) et le soudage des surfaces du tuyau et du raccord
3.7.2
assemblage par soudage bout à bout
assemblage réalisé par chauffage des extrémités planes des surfaces qui coïncident, en les maintenant contre
une plaque chauffante plane jusqu’à ce que la matière PE atteigne la température de fusion, en retirant la
plaque chauffante rapidement et en appliquant les deux extrémités ramollies l’une contre l’autre
2 © ISO 2011 – Tous droits réservés

---------------------- Page: 8 ----------------------
ISO 11299-3:2011(F)
3.7.3
assemblage mécanique
assemblage effectué par assemblage d’un tuyau en PE avec un autre tuyau en PE, ou tout autre élément du
système de canalisations qui comprend généralement une partie de compression qui assure la tenue à la
pression, l’étanchéité et la résistance à l’effet de fond
NOTE  Un manchon de support inséré à l’intérieur du trou du tuyau peut être utilisé pour fournir un support permanent
pour le tuyau en PE afin d’empêcher un fluage dans la paroi du tuyau soumise à des forces de compression radiales.
3.7.4
compatibilité au soudage
capacité de deux matières PE semblables ou différentes à être soudées ensemble pour former un assemblage
qui réponde aux exigences de performance de la présente partie de l’ISO 11299
4 Symboles et abréviations
4.1 Symboles
C
coefficient global de service (de calcul)
d diamètre extérieur (en un point quelconque)
e
d diamètre extérieur moyen maximal
em,max
d diamètre extérieur moyen minimal
em,min
d diamètre circulaire d’origine du tuyau (avant traitement pour insertion)
manuf
e épaisseur de paroi moyenne maximale
m,max
T température à laquelle les données de contraintes de rupture ont été déterminées
t tenue du tuyau avant l’apparition d’une fuite
t tolérance sur l’épaisseur de paroi
y
σ contrainte de calcul
s
4.2 Abréviations
LPL limite inférieure de confiance de la résistance hydrostatique prévue
MFR indice de fluidité à chaud en masse
MOP pression maximale de service
MRS résistance minimale requise
PE polyéthylène
R série de nombres normaux, conforme à la série de Renard
SDR rapport de dimensions standard
© ISO 2011 – Tous droits réservés  3

---------------------- Page: 9 ----------------------
ISO 11299-3:2011(F)
5 Tuyaux au stade «M»
5.1 Matières
5.1.1 Matière vierge
La matière vierge utilisée doit être conforme à une des désignations des compositions de PE données dans
le Tableau 1.
Tableau 1 — Désignations des compositions de PE
Désignation Classification par MRS
MPa
PE 80 8
PE 100 10
La composition doit être conforme à l’ISO 4437.
5.1.2 Matière retraitable et matière régénérée
Conformément à l’ISO 4437, la matière retraitable interne peut être utilisée, sous réserve qu’elle provienne de
la même composition, comme utilisée pour la fabrication concernée.
La matière retraitable obtenue à partir de sources externes et la matière régénérée ne doivent pas être utilisées.
5.2 Caractéristiques générales
5.2.1 Aspect
Lors de l’inspection sans grossissement, les surfaces interne et externe du tuyau doivent être lisses, propres
et exemptes de rayures, de cavités, ainsi que de tout autre défaut susceptibles d’entraver leur conformité à la
présente partie de l’ISO 11299.
5.2.2 Couleur
Les tuyaux doivent être jaunes ou orange, ou noirs avec des bandes d’identification jaunes ou orange.
5.3 Caractéristiques des matières
Les matières à partir desquelles les tuyaux sont fabriqués doivent être conformes aux exigences spécifiées
dans l’ISO 4437:2007, Tableau 1.
5.4 Caractéristiques géométriques
Le diamètre du tuyau, l’épaisseur de paroi et la forme au stade «M» dépendent de la technique spécifique de
tubage par tuyau continu sans espace annulaire. Les dimensions au stade «M» nécessaires pour respecter les
dimensions du stade «I» (voir 8.4) doivent être déclarées, avec leurs tolérances, par le fabricant.
NOTE  Dans le cas de tuyaux pliés en usine, il est possible qu’il y ait des variations d’épaisseur de paroi dans une
section transversale. Cela est acceptable tant que le tuyau plié a la propriété qui permet d’obtenir une épaisseur de paroi
selon 8.4 lorsque l’installation est achevée.
5.5 Caractéristiques mécaniques
Lorsqu’il est soumis à essai conformément à la méthode d’essai donnée dans le Tableau 2, le tuyau doit être
conforme aux exigences du tableau.
4 © ISO 2011 – Tous droits réservés

---------------------- Page: 10 ----------------------
ISO 11299-3:2011(F)
Tableau 2 — Caractéristiques mécaniques des tuyaux
Paramètres d’essai
Méthode
Caractéristique Exigence
d’essai
Paramètres Valeur
Allongement à la rupture
a
ISO 4437
Résistance hydrostatique (80 °C, 165 h)
a
  Le tuyau doit être rétabli à son état initial dans le cas de tuyaux pliés en usine.
5.6 Caractéristiques physiques
Les caractéristiques physiques doivent être conformes à celles spécifiées dans l’ISO 4437. Dans le cas de
tuyaux pliés en usine, remis en forme sous l’
...

Questions, Comments and Discussion