Soil quality — Determination of redox potential — Field method

ISO 11271:2002 specifies a field method for the determination of soil redox potential (Eh). NOTE The electrochemical measurement of redox potential described here is possible only if the relevant soil horizon has a moisture status defined as fresh or wetter according to the classes presented in annex D.

Qualité du sol — Détermination du potentiel d'oxydoréduction — Méthode de terrain

L'ISO 11271 spécifie une méthode de terrain pour la détermination du potentiel d'oxydoréduction, ou potentiel redox, d'un sol (Eh). NOTE Le mesurage électrochimique du potentiel redox décrit n'est possible que pour un horizon de sol dont le degré d'humidité est défini comme frais ou plus humide, selon la classification présentée à l'annexe D.

General Information

Status
Not Published
Current Stage
6000 - International Standard under publication
Start Date
26-May-2022
Completion Date
26-May-2022
Ref Project

RELATIONS

Buy Standard

Draft
REDLINE ISO 11271 - Soil quality — Determination of redox potential — Field method Released:3/16/2022
English language
13 pages
sale 15% off
Preview
sale 15% off
Preview
Draft
ISO 11271 - Soil quality — Determination of redox potential — Field method Released:3/16/2022
English language
13 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (sample)

ISO 11271:2022(E)
ISO TC 190/SC 3/WG 14
Date: YYYY-MM-DD2022-03-16
Soil quality — Determination of redox potential — Field method
DIS stage
Warning for WDs and CDs

This document is not an ISO International Standard. It is distributed for review and comment. It is subject to

change without notice and may not be referred to as an International Standard.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of

which they are aware and to provide supporting documentation.
© ISO #### – All rights reserved
---------------------- Page: 1 ----------------------
© ISO 2021
---------------------- Page: 2 ----------------------
ISO/FDIS 11271:2022(E)
© ISO 2022

All rights reserved. Unless otherwise specified, or required in the context of its implementation, no

part of this publication may be reproduced or utilized otherwise in any form or by any means,

electronic or mechanical, including photocopying, or posting on the internet or an intranet, without

prior written permission. Permission can be requested from either ISO at the address below or

ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.orgwww.iso.org
Published in Switzerland
4 © ISO #### – All rights reserved
iv © ISO 2022 – All rights reserved
---------------------- Page: 3 ----------------------
ISO/FDIS 11271:2022(E)
Contents

Foreword ............................................................................................................................................................ iv

Introduction ....................................................................................................................................................... v

1 Scope ....................................................................................................................................................... 1

2 Normative references ....................................................................................................................... 1

3 Terms and definitions ....................................................................................................................... 1

4 Principle ................................................................................................................................................ 1

5 Apparatus .............................................................................................................................................. 2

The rod shall have a length which allows the redox electrodes to be inserted to the desired

depth in the soil. ................................................................................................................................. 2

6 Reagents ................................................................................................................................................ 3

Use either buffered quinhydrone solution (prepared by adding quinhydrone to a pH buffer

to obtain a suspension), or an equimolar solution of potassium

hexacyanoferrate(III) and potassium hexacyanoferrate(II) (see Annex B). ................... 3

7 Site selection and sampling ............................................................................................................. 3

8 Procedure ............................................................................................................................................. 3

8.1 Care, cleaning and testing of the redox electrode system ..................................................... 3

8.2 Preparation of site and measurement of redox potential ..................................................... 4

9 Evaluation ............................................................................................................................................. 4

10 Expression of results ......................................................................................................................... 4

11 Test report ............................................................................................................................................ 5

Annex A (informative) Description of the construction of redox electrodes, of the salt

bridge, and their arrangement during measurement ............................................................ 6

A.1 Redox electrode .................................................................................................................................. 6

A.2 Salt bridge (Figure A.2) ..................................................................................................................... 7

A.3 Arrangement of the electrodes during measurement (Figure A.3) .................................... 8

Annex B (informative) Potentials of platinum electrodes in different solutions .................... 10

Annex C (informative) Potentials of reference electrodes .............................................................. 11

Annex D (informative) Soil moisture status ........................................................................................ 12

Bibliography ................................................................................................................................................... 13

© ISO #### – All rights reserved 5
© ISO 2022 – All rights reserved v
---------------------- Page: 4 ----------------------
ISO/FDIS 11271:2022(E)
Foreword

ISO (the International Organization for Standardization) is a worldwide federation of national standards

bodies (ISO member bodies). The work of preparing International Standards is normally carried out

through ISO technical committees. Each member body interested in a subject for which a technical

committee has been established has the right to be represented on that committee. International

organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO

collaborates closely with the International Electrotechnical Commission (IEC) on all matters of

electrotechnical standardization.

The procedures used to develop this document and those intended for its further maintenance are

described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the

different types of ISO documents should be noted. This document was drafted in accordance with the

editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).

Attention is drawn to the possibility that some of the elements of this document may be the subject of

patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of any

patent rights identified during the development of the document will be in the Introduction and/or on

the ISO list of patent declarations received (see www.iso.org/patents).

Any trade name used in this document is information given for the convenience of users and does not

constitute an endorsement.

For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and

expressions related to conformity assessment, as well as information about ISO's adherence to the World

Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see

www.iso.org/iso/foreword.html.

This document was prepared by Technical Committee ISO/TC 190, Soil quality, Subcommittee SC 3,

Chemical and physical characterization.

This second edition cancels and replaces the first edition (ISO 11271:2001),2002), of which has been

technically revised.
it constitutes a minor revision. The main changes are as follows:
— update of normative references;
— update of bibliography;
— editorially revised.

Any feedback or questions on this document should be directed to the user’s national standards body. A

complete listing of these bodies can be found at www.iso.org/members.html.
6 © ISO #### – All rights reserved
vi © ISO 2022 – All rights reserved
---------------------- Page: 5 ----------------------
ISO/FDIS 11271:2022(E)
Introduction

The redox potential is a physico-chemical parameter used to characterize soil aeration status in a global

way. Under field conditions, it gives information on the condition of oxidation or reduction of those

compounds which, according to cases, play an important part in plant nutrition, can induce toxicity

phenomena or intervene in gas transfers to the atmosphere (greenhouse effect). It can also be used to a

certain extent to follow soil performances in case of sludge disposal or composting, and to adjust

applications accordingly. Under laboratory conditions it can be used in order to study oxygen diffusion

phenomena to aggregate level.
© ISO #### – All rights reserved 7
© ISO 2022 – All rights reserved vii
---------------------- Page: 6 ----------------------
FINAL DRAFT INTERNATIONAL STANDARD ISO/FDIS 11271:2022(E)
Soil quality — Determination of redox potential — Field method
1 Scope

This International Standarddocument specifies a field method for the determination of soil redox

potential (E ).

NOTE The electrochemical measurement of redox potential described herein this document is possible only if

the relevant soil horizon has a moisture status defined as fresh or wetter according to the classes presented in annex

Annex D.
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

— ISO Online browsing platform: available at https://www.iso.org/obphttps://www.iso.org/obp

— IEC Electropedia: available at https://www.electropedia.org/
3.1
redox potential (E )

electrochemical potential reflecting the oxidation-reduction status of a liquid chemical system (in this

case of the soil solution)
4 Principle

Redox potential is an electrochemical equivalent of the free energy of redox reactions, and for an

equilibriatedequilibrated single redox system of the general form:
− +
𝐴𝐴 + 𝑛𝑛e + 𝑚𝑚H ⇌𝑅𝑅 A + neH+ m ≥ A (1)
ox ed ox red
is given by the Nernst equation:
𝑅𝑅𝑅𝑅 𝐴𝐴 2,303 𝑚𝑚𝑅𝑅𝑅𝑅
0 ox
𝐸𝐸 = 𝐸𝐸 + ln − 𝑝𝑝𝑝𝑝 (2)
𝑛𝑛𝑛𝑛 𝐴𝐴 𝑛𝑛𝑛𝑛
Red
RT 2,303 mRT Field Code Changed
0 ox
E = E + ln − pH (2)
nF A nF
Red
where
© ISO 2022 – All rights reserved 1
---------------------- Page: 7 ----------------------
ISO/FDIS 11271:2022(E)

Aox and ARed are the activities of the oxidized and reduced forms of the element, respectively;

e refers to the electron(s) involved in the reaction;
H refers to the proton(s) involved in the reaction;

n and m are the numbers of electrons and protons involved in the reaction, respectively;

0 0
is the standard value of the potential in volt (V) i.e. when A = A and pH = 0;
𝐸𝐸 E ox Red
R -1 -1
is the universal gas constant (8,314 1 J mol · K );
T is the absolute temperature in kelvin (K);
F -1
is the Faraday constant (96 500 C · mol );
2,303 is the natural log of 10.
Redox potential is related to electron activity (e ) in the system as follows:
𝑅𝑅𝑅𝑅 RT
Field Code Changed
− −
𝐸𝐸 = ln (𝑒𝑒 ) E ln (e) (3)
h h
𝑛𝑛

NOTE Users of this International Standarddocument unfamiliar with these electrochemical concepts

should consult appropriate texts, or seek professional advice.

The electrometric determination of redox potential is analogous to the determination of pH. The

determination of E follows the principle of measuring potential differences between an inert measuring

electrode (usually a platinum electrode) i.e. an electrode not reacting with the solution per se, with

respect to the standard hydrogen electrode used as the reference electrode. Many redox systems are

involved in the soil solution, and the resulting potential is a mixed potential depending on the existing

electroactive redox couples. For practical reasons, a silver-silver chloride electrode is usually used as the

reference electrode, the potential of which is added to the measured potential difference (see Annex C)

in order to obtain the values expressed on the basis of the standard hydrogen electrode.

5 Apparatus
The following apparatus shall be used.

5.1 Millivoltmeter, with an input resistance not less than 10 GΩGΩ and sensitivity of 1 mV.

5.2 A set of redox-electrodes, constructed as described in A.1.
All electrodes should be sufficiently robust for field use. (see Annex A).

5.3 Reference electrode: silver/silver chloride reference electrode in 1 mol/l or 3 mol/l potassium

chloride solution.

Other reference electrodes such as the calomel electrode can also be used, but are not recommended

because of the health hazard connected with the use of mercury. The potential of such reference

electrodes with respect to the standard hydrogen electrode is given in Annex B. Reference electrodes

should be stored in a potassium chloride solution (see 6.4) of the same concentration as that present in

the electrode, or directly in the salt bridge (see 5.5) containing the same concentration of potassium

chloride. It should be noted that lower concentrations of potassium chloride will reduce contamination

of the soil with this salt.
2 © ISO #### – All rights reserved
2 © ISO 2022 – All rights reserved
---------------------- Page: 8 ----------------------
ISO/FDIS 11271:2022(E)

5.4 Rigid rod, (stainless steel has been found suitable), 20 cm to 100 cm in length with the diameter

2 mm greater than that of the redox electrodes (see 5.2).

The rod shall have a length which allows the redox electrodes to be inserted to the desired depth in the

soil.
5.5 Salt bridge, to connect the reference electrode with the soil (see A.2).

5.6 Hand auger, with a diameter 3 mm to 5 mm greater than that of the salt bridge.

5.7 Electrode cleaning materials: finest grade of steel wool, scouring powder and some cotton cloth

have been found suitable.

5.8 Thermometer, to measure the temperature at the location of the reference electrode (see

clauseClause 8) with an accuracy of 1 °C.
6 Reagents
6.1 Redox buffer solution, to calibrate the redox electrodes.

Use either buffered quinhydrone solution (prepared by adding quinhydrone to a pH buffer to obtain a

suspension), or an equimolar solution of potassium hexacyanoferrate(III) and potassium

hexacyanoferrate(II) (see Annex B).

6.2 Water, with an electrical conductivity less than 0,1 mS m (equivalent to resistivity greater than

0,01 MΩ m at 25 °C).

6.3 Agar, ρ = 0,5 %, in a potassium chloride solution of the same concentration as that in the reference

electrode.

6.4 Potassium chloride solution, of the same concentration as that chosen in 5.3.

NOTE This solution is used to store the reference electrode and to add to the salt bridge, as needed.

7 Site selection and sampling

The selection and description of the place of measurement, and of samples for laboratory measurement,

should follow the guidelines given in the ISO 18400 series and ISO 11464.
8 Procedure
8.1 Care, cleaning and testing of the redox electrode system

The platinum electrodes shall be stored in air and kept clean. They shall be inspected for damage and/or

contamination at intervals of not more than one year, and every time they are used. Oils, fats and waxes,

and other chemicals likely to adhere are particularly damaging to electrode performance. If contaminated

with soil material, they shall be cleaned gently with a cotton cloth, and rinsed with distilled water. In

cases of severe contamination, e.g. with oils etc. (above),, an appropriate solvent, followed by scouring

material (see 5.7),) shall be used (see Note, below)..
© ISO #### – All rights reserved 3
© ISO 2022 – All rights reserved 3
---------------------- Page: 9 ----------------------
ISO/FDIS 11271:2022(E)

The reference electrode(s) shall also be inspected at the same time as the platinum electrode(s). Any

visible change in the colour or transparency of the potassium chloride electrolyte solution indicates

probable trouble. In such cases the reference electrode shall not be used. Crystals of potassium chloride

are, however, a normal feature of saturated potassium chloride solutions, and are no reason to reject the

...

FINAL
INTERNATIONAL ISO/FDIS
DRAFT
STANDARD 11271
ISO/TC 190/SC 3
Soil quality — Determination of redox
Secretariat: DIN
potential — Field method
Voting begins on:
2022-03-30
Qualité du sol — Détermination du potentiel d'oxydoréduction —
Méthode de terrain
Voting terminates on:
2022-05-25
RECIPIENTS OF THIS DRAFT ARE INVITED TO
SUBMIT, WITH THEIR COMMENTS, NOTIFICATION
OF ANY RELEVANT PATENT RIGHTS OF WHICH
THEY ARE AWARE AND TO PROVIDE SUPPOR TING
DOCUMENTATION.
IN ADDITION TO THEIR EVALUATION AS
Reference number
BEING ACCEPTABLE FOR INDUSTRIAL, TECHNO-
ISO/FDIS 11271:2022(E)
LOGICAL, COMMERCIAL AND USER PURPOSES,
DRAFT INTERNATIONAL STANDARDS MAY ON
OCCASION HAVE TO BE CONSIDERED IN THE
LIGHT OF THEIR POTENTIAL TO BECOME STAN-
DARDS TO WHICH REFERENCE MAY BE MADE IN
NATIONAL REGULATIONS. © ISO 2022
---------------------- Page: 1 ----------------------
ISO/FDIS 11271:2022(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2022

All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may

be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on

the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below

or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
© ISO 2022 – All rights reserved
---------------------- Page: 2 ----------------------
ISO/FDIS 11271:2022(E)
Contents Page

Foreword ........................................................................................................................................................................................................................................iv

Introduction .................................................................................................................................................................................................................................v

1 Scope ................................................................................................................................................................................................................................. 1

2 Normative references ..................................................................................................................................................................................... 1

3 Terms and definitions .................................................................................................................................................................................... 1

4 Principle ........................................................................................................................................................................................................................ 1

5 Apparatus .................................................................................................................................................................................................................... 2

6 Reagents ........................................................................................................................................................................................................................ 3

7 Site selection and sampling ...................................................................................................................................................................... 3

8 Procedure ....................................................................................................................................................................................................................3

8.1 Care, cleaning and testing of the redox electrode system ............................................................................... 3

8.2 Preparation of site and measurement of redox potential ................................................................................ 4

9 Evaluation ................................................................................................................................................................................................................... 4

10 Expression of results ....................................................................................................................................................................................... 4

11 Test report .................................................................................................................................................................................................................. 5

Annex A (informative) Description of the construction of redox electrodes, the salt bridge,

and their arrangement during measurement ...................................................................................................................... 6

Annex B (informative) Potentials of platinum electrodes in different solutions .............................................10

Annex C (informative) Potentials of reference electrodes ........................................................................................................11

Annex D (informative) Soil moisture status .............................................................................................................................................12

Bibliography .............................................................................................................................................................................................................................13

iii
© ISO 2022 – All rights reserved
---------------------- Page: 3 ----------------------
ISO/FDIS 11271:2022(E)
Foreword

ISO (the International Organization for Standardization) is a worldwide federation of national standards

bodies (ISO member bodies). The work of preparing International Standards is normally carried out

through ISO technical committees. Each member body interested in a subject for which a technical

committee has been established has the right to be represented on that committee. International

organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.

ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of

electrotechnical standardization.

The procedures used to develop this document and those intended for its further maintenance are

described in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the

different types of ISO documents should be noted. This document was drafted in accordance with the

editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).

Attention is drawn to the possibility that some of the elements of this document may be the subject of

patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of

any patent rights identified during the development of the document will be in the Introduction and/or

on the ISO list of patent declarations received (see www.iso.org/patents).

Any trade name used in this document is information given for the convenience of users and does not

constitute an endorsement.

For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and

expressions related to conformity assessment, as well as information about ISO's adherence to

the World Trade Organization (WTO) principles in the Technical Barriers to Trade (TBT), see

www.iso.org/iso/foreword.html.

This document was prepared by Technical Committee ISO/TC 190, Soil quality, Subcommittee SC 3,

Chemical and physical characterization.

This second edition cancels and replaces the first edition (ISO 11271:2002), of which it constitutes a

minor revision. The changes are as follows:
— update of normative references;
— update of bibliography;
— editorially revised.

Any feedback or questions on this document should be directed to the user’s national standards body. A

complete listing of these bodies can be found at www.iso.org/members.html.
© ISO 2022 – All rights reserved
---------------------- Page: 4 ----------------------
ISO/FDIS 11271:2022(E)
Introduction

The redox potential is a physico-chemical parameter used to characterize soil aeration status in a global

way. Under field conditions, it gives information on the condition of oxidation or reduction of those

compounds which, according to cases, play an important part in plant nutrition, can induce toxicity

phenomena or intervene in gas transfers to the atmosphere (greenhouse effect). It can also be used

to a certain extent to follow soil performances in case of sludge disposal or composting, and to adjust

applications accordingly. Under laboratory conditions it can be used in order to study oxygen diffusion

phenomena to aggregate level.
© ISO 2022 – All rights reserved
---------------------- Page: 5 ----------------------
FINAL DRAFT INTERNATIONAL STANDARD ISO/FDIS 11271:2022(E)
Soil quality — Determination of redox potential — Field
method
1 Scope

This document specifies a field method for the determination of soil redox potential (E ).

NOTE The electrochemical measurement of redox potential described in this document is possible only if

the relevant soil horizon has a moisture status defined as fresh or wetter according to the classes presented in

Annex D.
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.

ISO and IEC maintain terminology databases for use in standardization at the following addresses:

— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1
redox potential (E )

electrochemical potential reflecting the oxidation-reduction status of a liquid chemical system (in this

case of the soil solution)
4 Principle

Redox potential is an electrochemical equivalent of the free energy of redox reactions, and for an

equilibrated single redox system of the general form:
An ++eH mA≥ (1)
ox red
is given by the Nernst equation:
RT 2,303 mRT
0 ox
EE=+ ln − pH (2)
nF A nF
Red
where

A and A are the activities of the oxidized and reduced forms of the element, respectively;

ox Red
e refers to the electron(s) involved in the reaction;
H refers to the proton(s) involved in the reaction;

n and m are the numbers of electrons and protons involved in the reaction, respectively;

© ISO 2022 – All rights reserved
---------------------- Page: 6 ----------------------
ISO/FDIS 11271:2022(E)
is the standard value of the potential in volt (V) i.e. when A = A and pH = 0;
ox Red
-1 -1
R is the universal gas constant (8,314 1 J mol · K );
T is the absolute temperature in kelvin (K);
F is the Faraday constant (96 500 C · mol );
2,303 is the natural log of 10.
Redox potential is related to electron activity (e ) in the system as follows:
E = ln ()e (3)

Users of this document unfamiliar with these electrochemical concepts should consult appropriate

texts or seek professional advice.

The electrometric determination of redox potential is analogous to the determination of pH. The

determination of E follows the principle of measuring potential differences between an inert measuring

electrode (usually a platinum electrode) i.e. an electrode not reacting with the solution per se, with

respect to the standard hydrogen electrode used as the reference electrode. Many redox systems are

involved in the soil solution, and the resulting potential is a mixed potential depending on the existing

electroactive redox couples. For practical reasons, a silver-silver chloride electrode is usually used

as the reference electrode, the potential of which is added to the measured potential difference (see

Annex C) in order to obtain the values expressed on the basis of the standard hydrogen electrode.

5 Apparatus
The following apparatus shall be used.

5.1 Millivoltmeter, with an input resistance not less than 10 GΩ and sensitivity of 1 mV.

5.2 A set of redox-electrodes, constructed as described in A.1.
All electrodes should be sufficiently robust for field use (see Annex A).

5.3 Reference electrode: silver/silver chloride reference electrode in 1 mol/l or 3 mol/l potassium

chloride solution.

Other reference electrodes such as the calomel electrode can also be used but are not recommended

because of the health hazard connected with the use of mercury. The potential of such reference

electrodes with respect to the standard hydrogen electrode is given in Annex B. Reference electrodes

should be stored in a potassium chloride solution (see 6.4) of the same concentration as that present in

the electrode, or directly in the salt bridge (see 5.5) containing the same concentration of potassium

chloride. It should be noted that lower concentrations of potassium chloride will reduce contamination

of the soil with this salt.

5.4 Rigid rod, (stainless steel has been found suitable), 20 cm to 100 cm in length with the diameter

2 mm greater than that of the redox electrodes (see 5.2).

The rod shall have a length which allows the redox electrodes to be inserted to the desired depth in the

soil.
5.5 Salt bridge, to connect the reference electrode with the soil (see A.2).

5.6 Hand auger, with a diameter 3 mm to 5 mm greater than that of the salt bridge.

© ISO 2022 – All rights reserved
---------------------- Page: 7 ----------------------
ISO/FDIS 11271:2022(E)

5.7 Electrode cleaning materials: finest grade of steel wool, scouring powder and some cotton cloth

have been found suitable.

5.8 Thermometer, to measure the temperature at the location of the reference electrode (see

Clause 8) with an accuracy of 1 °C.
6 Reagents
6.1 Redox buffer solution, to calibrate the redox electrodes.

Use either buffered quinhydrone solution (prepared by adding quinhydrone to a pH buffer to

obtain a suspension), or an equimolar solution of potassium hexacyanoferrate(III) and potassium

hexacyanoferrate(II) (see Annex B).

6.2 Water, with an electrical conductivity less than 0,1 mS m (equivalent to resistivity greater than

0,01 MΩ m at 25 °C).

6.3 Agar, ρ = 0,5 %, in a potassium chloride solution of the same concentration as that in the reference

electrode.

6.4 Potassium chloride solution, of the same concentration as that chosen in 5.3.

NOTE This solution is used to store the reference electrode and to add to the salt bridge, as needed.

7 Site selection and sampling

The selection and description of the place of measurement, and of samples for laboratory measurement,

should follow the guidelines given in the ISO 18400 series and ISO 11464.
8 Procedure
8.1 Care, cleaning and testing of the redox electrode system

The platinum electrodes shall be stored in air and kept clean. They shall be inspected for damage

and/or contamination at intervals of not more than one year, and every time they are used. Oils, fats

and waxes, and other chemicals likely to adhere are particularly damaging to electrode p

...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.