General principles of design of fibrous (gypsum) plaster works

This European Standard defines the principles for the design of works carried out using fibrous (gypsum) plaster products as defined in EN 13815.
Fibrous (gypsum) plaster casts from the three categories of production below (see Clause 4 of
EN 13815:2006) should be involved:
a)   'cpp' allowing regulatory marking CE;
b)   'cppv' allowing regulatory marking CE;
c)   'ipp' either when CE marking is required;
or without CE marking (see Annex D - Note 2 of EN 13815:2006).
This European Standard applies to both new constructions and to the refurbishment, restructuring or conversion of existing buildings.
The common fields of application of fibrous plaster are as set out in Table 1 below.
Table 1 - Common fields of application of fibrous plaster
Fibrous plastering work should be capable of having the usual finishes applied directly to them (e.g. paint, wallpaper) subject to the normal preparatory work applicable for the type of finish.

Allgemeine Grundsätze der Planung von Arbeiten aus Formteilen aus faserverstärktem Gips

Diese Europäische Norm legt die Grundsätze für die Planung von Arbeiten fest, die unter Verwendung der in  EN 13815 beschriebenen Produkte aus faserverstärktem Gips ausgeführt werden.
Formteile aus faserverstärktem Gips aus den nachstehenden drei Produktionsgattungen (siehe Abschnitt 4 der EN 13815:2006) sollten einbegriffen sein:
   cpp ermöglicht die geregelte CE-Kennzeichnung;
   cppv ermöglicht die geregelte CE-Kennzeichnung;
   ipp beide wenn Ce-Kennzeichnung erforderlich ist;
   oder ohne CE-Kennzeichnung (siehe Anhang D  Anmerkung 2 von EN 13815:2006).
Diese Norm gilt sowohl für Neubauten als auch für Modernisierung, Sanierung oder Umbau von  bestehenden Gebäuden.
Die üblichen Anwendungsbereiche für Formteile aus faserverstärktem Gips sind nachstehend in Tabelle 1 aufgeführt.
Tabelle 1  Übliche Anwendungsbereiche für Formteile aus faserverstärktem Gips
Anwendungsbereich   Beispiel
Architektonische Effekte      Dekorativ: Gesimse, Wandpfeiler, Säulen (siehe nachstehend Ausnahme vii);
   an der Decke: glatte oder profilierte Decken (einschließlich abge¬hängter Decken), Kassettendecken, Gewölbe, Kuppeln;
   vertikal angeordnet: glatte oder profilierte Flächen (Trennwände, Bekleidungen);
   Ummantelungen, Bekleidungen;
   Zierteile für direkte oder indirekte Beleuchtung;
   Konstruktionen zur Verbesserung der akustischen Raumeigenschaften (Dämmung, Absorption, Ausbreitung).
Technische Funktionen      Schächte und Kanäle für Lüftung, Klimatisierung, Rauchabzug;
   Deckenzwischenräume und Druckkammern;
   Konstruktionen zur Erhöhung der Brandsicherheit.
ANMERKUNG 1   Diese Klassifizierung ist nicht ausschließend, weil die gleiche Arbeit aus Formteilen aus faserverstärktem Gips verschiedene Funktionen haben kann.
ANMERKUNG 2   In Tabelle 1 ist die Außenanwendung von Produkten aus faserverstärktem Gips nicht erwähnt, weil diese nur unter bestimmten Bedingungen angewendet werden können (siehe 4.3.1.2).

Principes généraux de conception des ouvrages en staff

La présente Norme Européenne détermine les principes généraux de conception des ouvrages à réaliser à l'aide des produits en staff définis par l’EN 13815.
Les éléments en staff des trois catégories de production indiquées ci-dessous (voir article 4 de l’EN 13815:2006) sont concernés :
a)   « cpp » justifiant le marquage réglementaire CE ;
b)   « cppv » justifiant le marquage réglementaire CE ;
c)   « ipp » lorsque le marquage CE est nécessaire ;
ou sans marquage CE (voir l’Annexe D  Note 2 de l’EN 13815:2006).
La présente Norme s’applique à des ouvrages à réaliser dans des bâtiments neufs ou existants, en construction, réhabilitation, restructuration ou réaménagement.
Les domaines courants d’application du staff sont désignés dans le Tableau 1 ci-dessous :
Tableau 1  Domaines courants d’application du staffDomaine d'application   Exemples
Ouvrages d'architecture intérieure    Décoration : corniches, pilastres, colonnes (voir exclusion ci-après) ;
Plafonds : plafonds plans ou en forme (plafonds suspendus inclus), plafonds à caissons, voûtes, coupoles ;
Parois verticales planes ou en forme (par exemple,  cloisons, contre-cloisons) ;
Coffrages et habillages divers ;
Ouvrages pour éclairage direct ou indirect ;
Ouvrages de traitement acoustique pour isolation, absorption et diffusion ;
Ouvrages à fonction technique    Conduits de ventilation, de traitement d'air, d'évacuation des fumées ;
Plénums et gaines techniques ;
Ouvrages de protection contre les risques d'incendie (par exemple, compartimentation au feu, protection contre le feu d'éléments structurels de la construction).
NOTE 1   Cette classification n'est pas formelle, un même ouvrage en staff pouvant avoir plusieurs fonctions.

Splošna načela za projektiranje in vgradnjo mavčnih odlitkov, ojačanih z vlakni

General Information

Status
Published
Publication Date
06-Nov-2007
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
23-Oct-2007
Due Date
28-Dec-2007
Completion Date
07-Nov-2007

Buy Standard

Standard
EN 15319:2007
English language
47 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.General principles of design of fibrous (gypsum) plaster worksPrincipes généraux de conception des ouvrages en staffAllgemeine Grundsätze der Planung von Arbeiten aus Formteilen aus faserverstärktem GipsTa slovenski standard je istoveten z:EN 15319:2007SIST EN 15319:2007en91.100.10Cement. Mavec. Apno. MaltaCement. Gypsum. Lime. MortarICS:SLOVENSKI
STANDARDSIST EN 15319:200701-december-2007







EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 15319July 2007ICS 91.100.10 English VersionGeneral principles of design of fibrous (gypsum) plaster worksPrincipes généraux de conception des ouvrages en staffAllgemeine Grundsätze der Planung von Arbeiten ausFormteilen aus faserverstärktem GipsThis European Standard was approved by CEN on 7 June 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2007 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 15319:2007: E



EN 15319:2007 (E) 2 Contents Page Foreword.3 Introduction.4 1 Scope.5 2 Normative references.6 3 Terms, definitions, symbols and abbreviations.7 3.1 General definitions.7 3.2 Technical definitions.8 3.3 Symbols and abbreviations.16 4 Design.16 4.1 General.16 4.2 Functions.20 4.3 Technical requirements.23 4.4 Essential requirements.34 5 Setting up on site and arrangements.36 5.1 Conditions required prior to commencing the installation of fibrous plaster works.36 5.2 Materials, equipment, accessories and other devices.39 6 Characteristics of the completed works.40 6.1 Surface appearance of the works.40 6.2 Flatness of work surfaces.41 6.3 Verticality of flat work surfaces.42 7 Maintenance and repair.42 Annex A (informative)
Separations at abutments and within the area of the works.43 A.1 Examples of situations likely to require separation at edges of work.43 A.2 Examples of situations likely to require sub-division.44 Annex B (informative)
Design values of thermal conductivity of gypsum plaster.45 Annex C (informative)
Painting works.46 Bibliography.47



EN 15319:2007 (E) 3 Foreword This document (EN 15319:2007) has been prepared by Technical Committee CEN/TC 241 “Gypsum and gypsum based products”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2008, and conflicting national standards shall be withdrawn at the latest by January 2008. This European Standard is one of a series of European standardization documents including:  construction products standards, concerning gypsum and gypsum based products;  works design standards, providing general principles for the design of works to realise with these products;  technical reports, providing rules and recommendations for installation of works on site realised with these same products. NOTE 1 The fibrous plaster products are the subject of EN 13815. NOTE 2 The rules and recommendations for installation of fibrous (gypsum) plaster works on site are the subject of the European Technical Report "Installation rules of fibrous (gypsum) plaster works".
According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.



EN 15319:2007 (E) 4 Introduction This European Standard applies to works carried out using fibrous (gypsum) plaster products made by the moulding of thin reinforced gypsum. The fibrous plaster work is installed by positioning these products and fastening them to the appropriate part of the built construction. Then they are sealed or screwed and jointed with plaster to form continuous surfaces without apparent joints. Fibrous plaster is used to enhance the architectural effects and the decorative effects to the interior of buildings, and to provide technical solutions. Examples of types of buildings where fibrous plastering works are often installed include: public buildings, banks, department stores, shopping malls, hotels, buildings for cultural and leisure activities, and churches. NOTE The figures used to illustrate this European Standard are intended to make the text easier to understand. Therefore, they should be taken as indicative and non-restrictive examples of the work described in the text.



EN 15319:2007 (E) 5 1 Scope This European Standard defines the principles for the design of works carried out using fibrous (gypsum) plaster products as defined in EN 13815. Fibrous (gypsum) plaster casts from the three categories of production below (see Clause 4 of
EN 13815:2006) should be involved: a) ”cpp” allowing regulatory marking CE; b) “cppv” allowing regulatory marking CE; c) “ipp” either when CE marking is required; or without CE marking (see Annex D – Note 2 of EN 13815:2006). This European Standard applies to both new constructions and to the refurbishment, restructuring or conversion of existing buildings. The common fields of application of fibrous plaster are as set out in Table 1 below. Table 1 — Common fields of application of fibrous plaster Fields of application Examples Architectural effects  decorating: cornices, pilasters, columns (see exception below);  on the ceiling: flat or shaped ceilings (included suspended ceilings), coffered ceilings, vaults, domes;  in a vertical position : flat or shaped surfaces (partitions, linings);  encasements, casings;  embellishments for direct or concealed lighting;  structures to improve acoustical performance (insulation, absorption, diffusion). Technical functions  shafts and ducts for ventilation, air conditioning, smoke extraction;  ceiling voids and chambers for pressurization;  structures to enhance fire safety. NOTE 1 This classification is not exclusive, as the same fibrous plaster work can have several functions. NOTE 2 Table 1 does not mention the use of fibrous plaster externally; as it can only be used under certain conditions (see 4.3.1.2). Fibrous plastering work should be capable of having the usual finishes applied directly to them (e.g. paint, wallpaper) subject to the normal preparatory work applicable for the type of finish.



EN 15319:2007 (E) 6 This European Standard should not apply to:  works formed from fibre reinforced gypsum sheet products, that are the subject of prEN 15283;  suspended ceilings formed from gypsum units and/or tills, installed dry in a framework, that are the subject of EN 14246;  works formed of solid casts;  run moulded plaster works formed in situ;  works formed from plaster based stucco casts, carton-pierre decors, resin decors;  fibrous plaster works which, by their nature, do not from an integral part of the structure by the use of permanent fixing (e.g. exhibition stands);  fibrous plaster works consisting of casts and embellishments, when they are to be applied directly to either new or existing wall or ceiling surfaces, for purely decorative applications (see Figures 3 and 4). Works of these types should be carried out in accordance with standard practice. This European Standard does not contain the regulatory requirements with which fibrous plaster works e.g. ceilings need to comply in certain buildings. NOTE In the field of safety, the main regulations relate to certain types of buildings, for example:  public buildings (PB);  high rise buildings (HRB);  buildings for educational purposes;  buildings for sanitary purposes. This European Standard does not deal with the ability of fibrous plastering works to comply with particular technical requirements (e.g. acoustical) needed in order for the works to comply with the requirements of the particular building contract. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 13279-1, Gypsum binders and gypsum plasters - Part 1: Definitions and requirements EN 13501-1, Fire classification of construction products and building elements - Part 1: Classification using test data from reaction to fire tests EN 13501-2, Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services EN 13815:2006, Fibrous gypsum plaster casts - Definitions, requirements and test methods EN 20140-9, Acoustics - Measurement of sound insulation in buildings and of building elements - Part 9: Laboratory measurements of room-to-room airborne sound insulation of a suspended ceiling with a plenum above it (ISO 140-9:1985)



EN 15319:2007 (E) 7 EN ISO 140-3, Acoustics - Measurements of sound insulation in buildings and of building elements - Part 3: Laboratory measurements of airborne sound insulation of building elements (ISO 140-3:1995) EN ISO 354, Acoustics - Measurement of sound absorption in a reverberation room (ISO 354:2003) EN ISO 717-1, Acoustics - Rating of sound insulation in buildings and of building elements - Part 1: Airborne sound insulation (ISO 717-1:1996) EN ISO 6946, Building components and building elements - Thermal resistance and thermal transmittance - Calculation method (ISO 6946:1996) EN ISO 10456, Building materials and products - Procedures for determining declared and design thermal values (ISO 10456:1999) 3 Terms, definitions, symbols and abbreviations For the purposes of this document, the following terms and definitions apply. 3.1 General definitions 3.1.1 fibrous (gypsum) plaster work completed work formed from the installation of fibrous plaster casts 3.1.2 fibrous (gypsum) plaster surface whole surface formed from fibrous plaster casts (e.g. ceiling, wall lining) 3.1.3 fibrous (gypsum) plaster cast product made by casting specified gypsum plaster mixed with water and reinforced with fibres, cloth, grilles, lathwork, lath or profiles. It may contain admixtures, fillers or aggregates as long as they will not contribute in any stage of the fire and they are not classified as dangerous substances in European regulations 3.1.4 fibrous (gypsum) interior architectural cast cast of any shape and configuration, intended for interior architecture works similar to those in Table 1 3.1.5 fibrous (gypsum) plaster technical function cast cast of any shape and configuration, intended for technical function similar to those in Table 1 3.1.6 fibrous (gypsum) plaster unit; slab flat rectangular cast 3.1.7 suspended ceiling ceiling hung at a distance below the floor or roof above (see Figures 1 a), 1 b), 1 c)) 3.1.8 partition self-supporting dividing wall, non load-bearing 3.1.9 wall lining dry covering to any internal building surface (see Figure 1 d))



EN 15319:2007 (E) 8 3.1.10 independent wall lining lining fixed independently from background 3.1.11 shaft space formed for carry air or smoke (e.g. ventilation) 3.1.12 duct space formed for the passage of cables, pipes etc. 3.1.13 ceiling void; plenum space between the suspended fibrous plaster ceiling and the soffit of the floor or roof above, allowing ducts, pipes and cables to be run (see Figures 1 a), 1 b), 1 c)) 3.1.14 depth of suspension distance between the point of fixing or anchoring to the background and the finished surface of the fibrous plaster cast in ceiling works, measured at the position of the fixing (see Figures 1 a), 1 b), 1 c), 2) 3.1.15 spacing from the background distance between the point of fixing or anchoring to the background and the finished surface of the fibrous plaster cast in vertical position works, measured at the position of the fixing (see Figure 1 d)) 3.1.16 background or supporting structure existing or specially constructed work of one of the two following types: a) backgrounds having a continuous surface such as masonry walls or reinforced concrete flooring (see Figures 1 and 2); b) metal, timber or other framed structures 3.2 Technical definitions 3.2.1 face visible surface of the fibrous plaster cast in the completed work 3.2.2 back non-visible surface of the fibrous plaster cast in the completed work 3.2.3 edge of the cast boundary of the cast 3.2.4 edge of the work peripheral limit of the fibrous plaster work 3.2.5 thickness distance between the face and the back of the fibrous plaster cast



EN 15319:2007 (E) 9 3.2.6 fixing to the background device for securing the fibrous plaster casts or the spaced fixing accessories directly to the background (see 5.2.2) 3.2.7 anchor fixing to the background which is partially or totally embedded in it (see Figures 1 and 2) 3.2.8 accessories for fixing and spacing from the background devices to ensure that the fibrous plaster casts forming the work are held in position (see 5.2.2) such as: a) hanger: spaced fixing accessory connecting horizontal fibrous plaster work (e.g. a ceiling) to the background (see Figures 1 a), 1,b), 1 c), 2); b) supporting lug: spaced fixing accessory connecting vertical fibrous plaster work (e.g. wall lining) to the background (see Figure 1 d)); c) intermediate framework: spaced fixing accessory formed from a lightweight intermediate framework generally made of primary and secondary framed parallel laths or sections (see Figures 1 and 2); d) attachment: spaced fixing accessory fixing the fibrous plaster cast to a hanger, a supporting lug or an intermediate framework (e.g. wad, screw) 3.2.9 handling framework separate component used to provide temporary rigidity and/or support to products during removal from its mould, handling and assembly, usually removed after use 3.2.10 wad; fixing pad scrim comprising natural fibres usually jute or sisal fully impregnated with plaster and extended to form a grip or handle, specially used for sealed fixing of fibrous plaster work. Glass fibres can be used too (long fibres weave or mat) 3.2.11 fibrous plastered rope long scrim comprising natural fibres usually jute or sisal, or strip of Hessian, fully impregnated with plaster and extended to form a grip, specially used for complementary reinforcement. Glass fibres can be used (long fibres weave or mat) 3.2.12 fibrous plastered coated with fibrous plaster or made from fibrous plaster 3.2.13 sealed system installed system using mainly wads and fibrous plastered ropes 3.2.14 screwed system installation system prioritizing screwing on standard frames



EN 15319:2007 (E) 10 3.2.15 GRG (glass fibre reinforced gypsum) cast specific product made from plaster – calcium sulphate hemihydrate alpha based or specially modified beta based - mixed with water and in which the elementary reinforcement is glass fibre 3.2.16 PMGRG (polymer modified glass fibre reinforced gypsum) cast specific product made from plaster - calcium sulphate hemihydrate alpha based or specially modified beta based - mixed with water with addition of resin and in which the elementary reinforcement is glass fibre.



EN 15319:2007 (E) 11
Key Background 1 timber Anchors - fixings 2a 2b screws + corner plate 2 nails driven in diagonally + securing wads Hangers 3 threaded rod - round wire Intermediate framework 4a 4b 4c 4d primary: U section secondary: U section fibrous plastered collar fastening primary to hanger fibrous plastered collar fastening secondary to primary Attachment 5 wad Cast 6a ceiling Figure 1 a) — Example of diagrams for the installation of fibrous plaster suspended ceilings (sealed system)



EN 15319:2007 (E) 12
Key Background 1 metal Fixings 2a 2b crocodile clip wad Hangers 3 threaded rod - round wire Intermediate framework 4a 4b 4c 4d 4e 4f primary: U section secondary: U section fibrous plastered collar fastening primary to hanger fibrous plastered collar fastening secondary to primary round wire fibrous plastered collar fastening round wire to secondary Attachment 5 wad Casts 6 shaped ceiling Figure 1 b) — Example of diagrams for the installation of fibrous plaster shaped ceilings (sealed system)



EN 15319:2007 (E) 13
Key Background 1 reinforced concrete Fixings 2 threaded bolt Hangers 3 threaded rod Intermediate framework 4a 4b 4c 4d primary channel secondary: furring channel bridle stirrup Attachment 5 screw Casts 6 ceiling Figure 1 c) — Example of diagrams for the installation of fibrous plaster suspended ceilings (screwed system)



EN 15319:2007 (E) 14
Key Background 1a 1b masonry reinforced concrete Anchors 2a 2b 2 nails driven in diagonally anchor Supporting lug 3 threaded rod or bracket Intermediate framework 4a 4b 4c 4d primary : U section secondary: U section fibrous plastered collar fastening primary to hanger fibrous plastered collar fastening secondary to primary Fixing Attachment 5a 5b wad wad Casts 6 wall linings Figure 1 d) — Example of diagrams for the installation of fibrous plaster wall linings (sealed system)



EN 15319:2007 (E) 15
Key Background 1 reinforced concrete Anchors - Fixing 2 threaded bolt + angle bracket Hanger 3 threaded rod Framework 4 U section Casts 5 shaft Figure 2 — Example of diagrams of the installation of fibrous plaster shaft for smoke extraction



EN 15319:2007 (E) 16 3.3 Symbols and abbreviations For the purposes of this document, the following symbols and abbreviations apply. 3.3.1 Reminder about abbreviations of standard EN 13815 useful during design of fibrous (gypsum) plaster works cpp: indicates conventional series production; cppv: indicates series production of products with varying properties; ipp: indicates individual (and non-series) production; f: reinforcement class - Consecutive number indicates the type of elementary reinforcement (see Table 2 of EN 13815:2006); f…m: indicates presence of complementary reinforcement by lightweight steel sections e.g. f2m; f…w: indicates presence of complementary reinforcement by softwood laths e.g. f3w. 3.3.2 Particular abbreviations to the present standard PB: public building; HRB: high rise building; GRG: glass fibre reinforced gypsum (see 3.2.15); PMGRG: polymer modified glass fibre reinforced gypsum (see 3.2.16); Dp: depth of suspension; Sp: spacing distance from the background. 4 Design 4.1 General 4.1.1 Information to be provided to the designer of the fibrous plastering works This designer of the fibrous plastering works should be provided with or obtain all the information listed as being required for the design in Table 2.



EN 15319:2007 (E) 17 Table 2 — Non-exclusive summary of the topics to be taken into account during design Topics Information required Comments and references a) Selection of the product The function(s) of work, its position in building, the technical circumstances, the requirements and local tradition; these will determine the choice of:  product (e.g. GRG);  type of reinforcement;  some additions (e.g. additives, admixtures, aggregates). The fibrous plastering contractor would normally choose product and the type of reinforcement. b) Selection of the installation system The function(s) of work, the nature and conditions of the background or supporting structures, the technical requirements, the need to allow for the passage of services equipments, the possible regulations (e.g. PB), the local tradition, may determine the installation system as well as the choice of spaced fixing accessories. The fibrous plastering contractor would normally choose the installation system. c) Moisture and humidity conditions Determination or measurement of the moisture conditions in the adjoining spaces when in normal use. See 4.3.1.1.1 See 4.3.1.1.2 d) Temperature of the areas Determination or measurement of the temperature conditions in normal use in planned areas. See 4.3.1.1.3 e) Exterior works Appraisal of the climatic conditions. See 4.3.1.2 f) Background or supporting structure Considering if the background or supporting structure will be robust enough to:  with stand the resultant mechanical stresses of the installation work,  allow direct anchorage or fixing of the fibrous plaster casts or space fixing accessories. This is especially important when installing fibrous plaster casts in an existing building. See 4.3.1.3 g) Passage of services Determination of the possible passage of services through voids in the work. To define implications for the work. See 4.3.2.1 To liaise between concerned trades. h) Item to be inserted into the work Determination of, nature, specification and position of possible planned insertions. Definition of implications for the work. See 4.3.2.2 To liaise between concerned trades. i) Point loads on the work Definition of suitable strengthening devices for the installation system. See 4.3.2.3 To liaise between concerned trades. j) Joints in the work Determination of the need for and the spacing/positioning of movement joints around the edge of the works and around penetrations and insertions. Also intermediate joints within the area of the works. See 4.3.2.4 "to be continued"



EN 15319:2007 (E) 18 Table 2 (concluded) k) Compatibility with materials in contact Checking for compatibility between materials, e.g. wood, cast iron, steel, plastic etc. as appropriate. See 4.3.2.4.3 To liaise between concerned trades. l) Compatibility with adjacent construction units Checking for non-compatibility. This can determine the need for separation at abutments. See 4.3.2.4.4 To liaise between concerned trades. m) Junctions with adjacent construction units Definition of junction details of the work with adjacent building units: doors, windows, stone, marble, woodwork, glass, mirror etc. To liaise between concerned trades. n) Exposure to damage Consideration of protection necessary against risk of damage e.g. abrasion, impact. See 4.3.2.6 and Clause 7 o) Compatibility of fibrous plaster with the planned finish or decoration of the work surface To be checked.
p) Lighting of work Checking the lighting conditions, natural and/or artificial, on the site and the appearance of the completed work e.g. angle of illumination. See 5.1.4 To liaise between concerned trades. q) Durability and maintenance In normal temperature, humidity and conditions of use, fibrous plaster is as durable as other building materials e.g. masonry. See Clause 7 r) Safety in case of fire Consideration of the regulatory requirements, according to the type and position of the fibrous plaster casts and the use of the building e.g. PB, HRB:  Euroclass;  fixed protection, fire compartimentation, specific ducts etc.
s) Protection against noise Consideration of the acoustic requirements of the work taking consideration of the use of the surrounding spaces. See 4.4.5 t) Treatment of the acoustics In areas which the purpose requires a faultless acoustics e.g. recording studio, concert hall: Definition of the objects of the work. See 4.4.5 To liaise with acoustic engineer if necessary. u) Energy economy and heat retention Definition for the work the consequences of contractual requirements in accordance to its purpose. See 4.4.6 v) Seismic risks Determination of the risk. Definition of the particular arrangements especially about the reinforcement and the installation system. See 4.3.2.5 w) Site inspection Considering whether a site inspection is necessary when undertaking work is an existing building.
4.1.2 Programme for fibrous plastering works 4.1.2.1 Stages for carrying out a fibrous plastering work Once the fibrous plastering contractor has been notified of the agreement of the contract and the drawings and working details have been submitted to him, the work of the fibrous plasterer is likely to consist of the phases existed in Table 3 below.



EN 15319:2007 (E) 19 Table 3 — Common stages for execution and examples of the assumed time required Examples of periods (weeks) N° Stages 200 m2 flat (decoration and some ceilings) Auditorium (ceiling and walls: 2 500 m2) 1 Preparation:
 analysis of the project by those responsible for manufacture and installation, in consultation with the estimator;
 if required: request for additional information;
 planning of the project in consultation with the Master of works and the trades affected;
 if required: preparation of additional working details not shown in the tender documents and seeking of the Master of works approval;
 technical organisation of the installation work;
 if required: preparation of the site organisation chart;
 site inspection (suitability and progress) 4 16 2 Fibrous plastering models and fibrous plastering moulds:
 preparation of special models and moulds required for manufacture 2 8 3 Manufacture:
 casting of the fibrous plaster casts in the contractor's workshop, or in a temporary workshop on site, and drying 2 12 4 Site installation:
 setting up on site and arrangements; — —
 if required: erection of scaffolding; — 3
 installation of the fibrous plaster work; 4 12
 if required: dismantling of scaffolding; — —
 drying natural or artificial (to a temperature less than 50 °C); 2 4 5  total period (allowing for possible overlap of tasks) 10 to 12 40 to 50 NOTE 1 The assumed periods of time shown in Table 3 are hypothetical; these periods should be defined for each project, depending on the complexity of the works and the conditions of execution. NOTE 2 The erection and dismantling of large scaffolds, together with the supply of related plant, may be included in the work to be carried out by the fibrous plaster contractor or may be covered in a special contract with a qualified contractor. 4.1.2.2 Conditions required before undertaking the installation of fibrous plaster work (see 5.1) 4.1.2.3 Programme content and work periods The work programme for the fibrous plastering works will form part of the general building programme for the whole project. It should be agreed with the fibrous
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.