Sanitary tapware - Pressure flushing valves and automatic closing urinal valves PN 10

This document applies to flushing valves for WCs and valves for urinals, with automatic hydraulic closure, intended for:
-   WC pans EN 997;
-   single flush urinals EN 13407;
-   siphon acting urinals EN 13407.
It does not apply to no-contact detection valves.
It is intended to specify:
-   marking and identification, physico-chemical, dimensional, leaktightness, pressure behaviour, hydraulic, mechanical endurance and acoustic characteristics of flushing valves for WCs and urinals with automatic closure;
-   test methods used to verify these characteristics;
-   and to determine requirements for the atmospheric interrupter which shall be an integral part of the WC flushing valve.
It applies in the following pressure and temperature conditions:
Table 1 — Conditions of use for tapware
Dynamic Pressure range recommended for a good working   Urinals
WC DN 15
WC DN 20   0,1 MPa ≤ P ≤ 0,5 MPa
(1 bar ≤ P ≤ 5 bar)
   WC DN 25   0,08 MPa ≤ P ≤ 0,25 MPa
(0,8 bar ≤ P ≤ 2,5 bar)
   WC DN 32   0,08 MPa ≤ P ≤ 0,25 MPa
(0,8 bar ≤ P ≤ 2,5 bar)
Maximum static pressure   1 MPa (10 bar)
Water temperature   ≤ 25 °C
NOTE 1   Although this document limits the pressure for WC DN 25 and WC DN 32 valves till 0,25 MPa (2,5 bar), some European countries have legislation and recommendations for higher pressures.
Health and quality requirements in accordance to European and national legislation for final materials in contact with water intended for human consumption are not covered by this document.

Sanitärarmaturen - WC- und Urinaldruckspüler mit selbsttätigem Abschluss PN 10

Das vorliegende Dokument gilt für WC Druckspüler und Urinaldruckspüler mit selbsttätigem Abschluss für:
-   WC Becken nach EN 997;
-   Verdrängungsbecken nach EN 13407;
-   Absaugurinale nach EN 13407.
Sie gilt nicht für berührungslos ausgelöste Armaturen.
Ihr Zweck ist die Festlegung von:
-   Anforderungen an Kennzeichnung und Markierung, an physikalisch chemische Eigenschaften, Maße, Dichtheit, Druckbeständigkeit, hydraulische Eigenschaften, mechanisches Zeitstandverhalten und Geräuschverhalten der WC Druckspüler und Urinaldruckspüler mit selbsttätigem Abschluss;
-   Verfahren zur Überprüfung dieser Eigenschaften;
-   Anforderungen an den Rohrunterbrecher, der integrierter Bestandteil des WC Druckspülers sein muss.
Sie findet unter folgenden Fließdruck  und Temperaturbedingungen Anwendung:
Tabelle 1 — Einsatzbedingungen für Armaturen
Empfohlener Fließdruckbereich für einwandfreien Betrieb   Urinal   0,1 MPa ≤ P ≤ 0,5 MPa
   WC DN 15   (1 bar ≤ P ≤ 5 bar)
   WC DN 20   
   WC DN 25   0,08 MPa ≤ P ≤ 0,25 MPa
      (0,8 bar ≤ P ≤ 2,5 bar)
   WC DN 32   0,08 MPa ≤ P ≤ 0,25 MPa
      (0,8 bar ≤ P ≤ 2,5 bar)
max. Ruhedruck   1 MPa (10 bar)
Wassertemperatur   ≤ 25 °C
ANMERKUNG 1   Obwohl dieses Dokument den Druck für WC DN 25 und WC DN 32 Druckspüler auf 0,25 MPa (2,5 bar) begrenzt, gibt es in einigen europäischen Ländern Gesetze und Empfehlungen für höhere Drücke.
Gesundheits  und Qualitätsanforderungen nach der europäischen und nationalen Gesetzgebung für Endmaterialien, die Kontakt mit Wasser für den menschlichen Gebrauch haben, werden in diesem Dokument nicht behandelt.

Robinetterie sanitaire - Robinets de chasse d'eau et d'urinoirs à fermeture hydraulique automatique PN 10

Le présent document s’applique aux robinets de chasses pour WC et aux robinets d’urinoirs, à fermeture hydraulique automatique, destinés aux :
-   cuvettes de WC, EN 997 ;
-   urinoirs à simple rinçage, EN 13407 ;
-   urinoirs à action siphonique, EN 13407.
Il ne s’applique pas aux robinets à détection sans contact.
Il a pour objet de fixer :
-   le marquage et l’identification, les caractéristiques physico-chimiques, dimensionnelles, d’étanchéité, de tenue en pression, hydrauliques, acoustiques, d’endurance mécanique des robinets de chasse d’eau et robinets d’urinoirs à fermeture automatique ;
-   les méthodes d’essais à employer pour vérifier ces caractéristiques ;
-   les exigences du rupteur atmosphérique qui doit faire partie intégrante du robinet de chasse d’eau.
Il s’applique dans les conditions de pression et température suivantes :
Tableau 1 — Conditions d’utilisation des robinetteries
Plage de pression dynamique recommandée pour un bon fonctionnement   Urinoirs
WC DN15
WC DN20   0,1 MPa ≤ P ≤ 0,5 MPa
(1 bar ≤ P ≤ 5 bar)
   WC DN25   0,08 MPa ≤ P ≤ 0,25 MPa
(0,8 bar ≤ P ≤ 2,5 bar)
   WC DN32   0,08 MPa ≤ P ≤ 0,25 MPa
(0,8 bar ≤ P ≤ 2,5 bar)
Pression statique maximale   1 MPa (10 bar)
Température de l’eau   ≤ 25 °C
NOTE 1   Bien que le présent document limite la pression pour les robinets de WC DN25 et WC DN32 à 0,25 MPa (2,5 bar), la législation et les recommandations de certains pays européens fixent des pressions plus élevées.
Le présent document ne traite pas des exigences de santé et de qualité fixées par la législation européenne et les réglementations nationales relatives aux matériaux finaux en contact avec l’eau destinée à la consommation humaine.

Sanitarne armature – Tlačni izplakovalniki in samozaporni izplakovalniki PN10 za WC in pisoarje

General Information

Status
Not Published
Public Enquiry End Date
18-Sep-2024
Current Stage
4020 - Public enquire (PE) (Adopted Project)
Start Date
05-Jul-2024
Due Date
22-Nov-2024

Relations

Buy Standard

Draft
prEN 12541:2024
English language
36 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-september-2024
Sanitarne armature – Tlačni izplakovalniki in samozaporni izplakovalniki PN10 za
WC in pisoarje
Sanitary tapware - Pressure flushing valves and automatic closing urinal valves PN 10
Sanitärarmaturen - WC- und Urinaldruckspüler mit selbsttätigem Abschluss PN 10
Robinetterie sanitaire - Robinets de chasse d'eau et d'urinoirs à fermeture hydraulique
automatique PN 10
Ta slovenski standard je istoveten z: prEN 12541
ICS:
91.140.70 Sanitarne naprave Sanitary installations
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

DRAFT
EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2024
ICS 91.140.70 Will supersede EN 12541:2002
English Version
Sanitary tapware - Pressure flushing valves and automatic
closing urinal valves PN 10
Robinetterie sanitaire - Robinets de chasse d'eau et Sanitärarmaturen - WC- und Urinaldruckspüler mit
d'urinoirs à fermeture hydraulique automatique PN 10 selbsttätigem Abschluss PN 10
This draft European Standard is submitted to CEN members for enquiry. It has been drawn up by the Technical Committee
CEN/TC 164.
If this draft becomes a European Standard, CEN members are bound to comply with the CEN/CENELEC Internal Regulations
which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.

This draft European Standard was established by CEN in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC
Management Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are
aware and to provide supporting documentation.

Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to change without
notice and shall not be referred to as a European Standard.

EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2024 CEN All rights of exploitation in any form and by any means reserved Ref. No. prEN 12541:2024 E
worldwide for CEN national Members.

Contents Page
European foreword . 4
Introduction . 5
1 Scope . 6
2 Normative references . 6
3 Terms and definitions and abbreviated terms . 7
3.1 Terms and definitions . 7
3.2 Abbreviated terms . 8
4 Classification and Designation . 8
4.1 Classification of flushing valves . 8
4.2 Classification of urinal valves . 9
4.3 Designation . 9
5 Marking . 9
6 Materials . 9
6.1 Condition of exposed surfaces and quality of coating . 9
7 Dimensional characteristics . 9
7.1 General comments on drawings . 9
7.2 WC flushing valve . 10
7.2.1 General. 10
7.2.2 Side-entry WC flushing valves . 11
7.2.3 Top-entry WC flushing valves . 12
7.3 Urinal valves . 12
7.3.1 General. 12
7.3.2 Top entry urinal valve . 13
7.3.3 Side-entry urinal valves . 14
8 Leaktightness characteristics . 14
8.1 General. 14
8.2 Leaktightness tests . 14
8.2.1 Test methods . 14
8.2.2 Leaktightness of the stop valve and leaktightness of tapware upstream of the seat . 15
8.2.3 Leaktightness of tapware downstream of the seat . 15
8.3 Leaktightness tests - Summary table . 16
9 Pressure resistance characteristics . 16
9.1 General. 16
9.2 Mechanical behaviour tests. 16
9.2.1 Test methods . 16
9.2.2 Mechanical behaviour upstream of the seat with the stop valve in the closed position . 17
9.2.3 Mechanical behaviour downstream of the seat with the stop valve in the open
position . 17
9.3 Mechanical behaviour tests - Summary table . 17
10 Hydraulic and flow characteristics of WC flushing valves . 17
10.1 General. 17
10.2 Test method for WC flushing valves . 18
10.2.1 Principle . 18
10.2.2 Test apparatus . 18
10.2.3 Measurement of impact force and requirements . 21
10.2.4 Fitting the WC flushing valve . 22
10.3 Outline of flow rate-time-volume-impact force test and requirements . 23
10.3.1 Definitions . 23
10.3.2 Test methodology . 24
10.3.3 Test at lower dynamic pressure . 25
10.3.4 Test at upper dynamic pressure . 26
10.4 Summary of requirements . 27
10.5 Measurement of water hammer . 28
10.5.1 Test method . 28
10.5.2 Requirements . 28
11 Principle and verification of atmospheric pipe interrupters of WC flushing valves . 28
11.1 General . 28
11.2 Atmospheric pipe interrupter composition . 28
11.2.1 General . 28
11.2.2 Requirements . 28
11.2.3 Measurement method of dry part . 28
11.3 Installation conditions . 29
11.4 Verification of absence of water splashes at backflow protection . 30
11.4.1 Test method . 30
11.4.2 Requirements . 30
11.5 Verification of operation at vacuum . 30
11.5.1 General . 30
11.5.2 Test method . 31
11.5.3 Requirements . 31
12 Hydraulic or flow characteristics of urinal valves . 31
12.1 General . 31
12.2 Test method for urinal valves . 31
12.2.1 Test apparatus . 31
12.3 Requirements . 32
13 Operating force .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.