This European standard deals with the safety of electrically operated commercial rinsing sinks used in commercial kitchens, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral, and 480 V for other appliances

  • Standard
    28 pages
    English language
    e-Library read for
    ×1 day

This European standard deals with the safety of electrically operated commercial rinsing sinks used in commercial kitchens, their rated voltage being not more than 250 V for single-phase appliances connected between one phase and neutral, and 480 V for other appliances

  • Amendment
    7 pages
    English language
    e-Library read for
    ×1 day

This document specifies requirements for pipe and integral joints of higher level of impact resistant PVC-M for the conveyance of water and waste water under pressure. The pipes are intended for installation below and above ground where they are not exposed to direct sunlight. This document also specifies the test parameters for the test methods in this document. This document is applicable to extruded PVC-M pipes without a socket and pipes with a socket (integral or not), intended to be used for the following purposes: water mains and services buried in the ground; conveyance of water above ground for both outside and inside buildings; buried and above-ground drainage and sewerage under pressure. This document is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water) intended for human consumption and for general purposes as well as for waste water under pressure. This document specifies pipes for the conveyance of water and waste water up to and including 45 °C. For temperatures between 25 °C and 45 °C, Figure A.1 applies. NOTE 1 The producer and the end-user can come to agreement on the possibilities of use for temperatures above 45 °C on a case-by-case basis This document specifies a range of pipe sizes and pressure classes, and gives requirements concerning colours. NOTE 2 It is the responsibility of the purchaser or specifier to make the appropriate selections concerning pipe sizes, pressure classes and colours, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

  • Standard
    39 pages
    English language
    sale 15% off

This document is a collection of interpretations related to the EN 115 series. This document collects interpretations to EN 115-1:2008+A1:2010 and EN 115-1:2017. Interpretations to other standards of the EN 115 series will be added when they are available.
Interpretations aim to improve the understanding of the clause(s) they are referring to and by that facilitating common understanding between manufacturers, installers, notified bodies, inspection bodies and national authorities.
Interpretations do not have the same status as the European standards to which they are related. However, the application of interpretations given to the interested parties confidence that the relevant European standard has not been wrongly applied.

  • Technical specification
    88 pages
    English language
    e-Library read for
    ×1 day

This document specifies requirements and provides recommendations for the design and installation of connections (bonds) between various electrically conductive elements in buildings and other structures, during their construction or refurbishment, in which information or telecommunications technology equipment is intended to be installed in order to: a) minimise the d.c. and a.c. potential differences in order to reduce the risk of malfunction of that equipment and interconnecting cabling due to electromagnetic disturbance; b) provide the telecommunications installation with a reliable signal reference – which may improve immunity from electromagnetic interference (EMI). The requirements of this European Standard are applicable to the buildings and other structures within premises addressed by EN 50174-2 (e.g. residential, office, industrial and data centres) but information given in this European Standard may be of assistance for other types of buildings and structures. NOTE Telecommunications centres (operator buildings) are addressed by ETSI/EN 300 253. This European Standard does not apply to power supply distribution of voltages over AC 1 000 V. Electromagnetic compatibility (EMC) requirements and safety requirements for power supply installation are outside the scope of this European Standard and are covered by other standards and regulations. However, information given in this European Standard may be of assistance in meeting the requirements of these standards and regulations.

  • Amendment
    49 pages
    English language
    e-Library read for
    ×1 day

This document specifies requirements and test methods for pipes and fittings which are part of piping systems for the rehabilitation, by means of renovation and trenchless replacement, of underground gas supply networks.
It is applicable to polyethylene (PE) pipes, fittings and assemblies, as manufactured and as installed. It is not applicable to the existing pipeline.
This document is applicable to the following technique families for renovation, intended to be used at an operating temperature of 20 °C as a reference temperature:
lining with continuous pipes;
lining with close-fit pipes.
This document is applicable to the following technique families for trenchless replacement, intended to be used at an operating temperature of 20 °C as a reference temperature:
pipe bursting and pipe extraction;
horizontal directional drilling and impact moling.
This document is applicable to:
PE solid wall single layered pipes (nominal outside diameter, dn), including any identification stripes;
PE pipes with co-extruded layers on either or both the outside and inside of the pipe (total outside diameter, dn), as specified in Annex D, where all layers have the same minimum required strength (MRS) rating.
Furthermore, when used with lining with continuous pipes and trenchless replacement, this document is applicable to:
PE coated pipes (outside diameter, dn) having a peelable, contiguous, thermoplastics additional layer on the outside of the pipe (“coated pipe”), as specified in Annex D.
NOTE            When used with lining with close-fit lining pipes, the lining pipe is reduced in the factory or on site to provide a close-fitting independent or interactive pressure pipe liner.
This document is applicable to jointing by means of butt fusion and electrofusion and to fabricated and injection-moulded fittings and mechanical connections of PE.
This document is not applicable to push-fit jointed discrete pipes assembled as part of the trenchless installation process.

  • Standard
    50 pages
    English language
    e-Library read for
    ×1 day

This document gives the specifications of the thermoplastic water meter cabinets. It specifies the thickness of material, design drawing, dimensions and accessories incorporated into the construction of it for pipe sizes from 12,7 mm to 31,75 mm.

  • Standard
    5 pages
    English language
    sale 15% off

This document specifies test methods for measuring the performance change of electrically powered household and similar air cleaners caused by the loading with particles. The main intention of the document is to compare differences in the performance change between air cleaners exposed to the same loading with particles. The performance change is not necessarily representative for real-use applications since concentration, size, morphology and chemical composition of particles present in household or similar environments can strongly differ.

  • Technical specification
    17 pages
    English language
    sale 15% off

This document specifies general requirements, such as ergonomic aspects in relation to ventilation of the kitchen (temperature, air aspects, moisture, noise, etc.), including a method for calculating the airflow rates.
This document is applicable to ventilation systems in commercial kitchens, associated areas and other installations processing foodstuffs intended for commercial use. Kitchens and associated areas are special rooms in which meals are prepared, where tableware and equipment is washed, cleaned and food is stored.
This document does not apply to kitchen ventilation systems in domestic kitchens.
This document does not apply to solid fuel appliances e.g. charcoal grills.
Unless otherwise specified, the requirements of this document are intended to be checked by way of inspection and/or measurement.
NOTE   Attention is drawn to the possible existence of additional or alternative national regulations on installation, appliance requirements and inspection, maintenance, operation.

  • Standard
    36 pages
    English language
    e-Library read for
    ×1 day

IEC TS 61200-201:2026 provides guidance, based on the general requirements provided in the IEC 60364 series, on the implementation of protective measures for low-voltage asynchronous motors. This document covers the control and the protection of low-voltage asynchronous motors.

  • Technical specification
    44 pages
    English language
    sale 15% off

This document specifies the definitions and requirements for buried circular manholes and inspection chambers installed to a maximum depth of 6 m from ground level to the invert of the main channel and manufactured from unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP), polypropylene with mineral modifiers (PP-MD) or polyethylene (PE). These products are intended for use in traffic areas and outside the building structure (application area code “U”) for wastewater (foul wastewater, domestic wastewater, surface water). NOTE 1 Products conforming with this document are also suitable in non-traffic areas. This document is only applicable to those chamber/manhole items where the manufacturer has clearly stated in the documentation how the components must be assembled to create a complete manhole or inspection chamber. The products covered by this document comprise the following: products providing access to the drain or sewer systems by means of inspection and cleaning equipment. products designated as manholes providing additionally human access to the drain or sewer systems. NOTE 2 Manholes and inspection chambers can be subject to national regulations and/or local provisions. NOTE 3 Products conforming with this document can be installed in underground applications without additional static calculations.

  • Standard
    23 pages
    English language
    sale 15% off

This document specifies requirements and provides recommendations for the design and installation of connections (bonds) between various electrically conductive elements in buildings and other structures, during their construction or refurbishment, in which information or telecommunications technology equipment is intended to be installed in order to: a) minimise the d.c. and a.c. potential differences in order to reduce the risk of malfunction of that equipment and interconnecting cabling due to electromagnetic disturbance; b) provide the telecommunications installation with a reliable signal reference – which may improve immunity from electromagnetic interference (EMI). The requirements of this European Standard are applicable to the buildings and other structures within premises addressed by EN 50174-2 (e.g. residential, office, industrial and data centres) but information given in this European Standard may be of assistance for other types of buildings and structures. NOTE Telecommunications centres (operator buildings) are addressed by ETSI/EN 300 253. This European Standard does not apply to power supply distribution of voltages over AC 1 000 V. Electromagnetic compatibility (EMC) requirements and safety requirements for power supply installation are outside the scope of this European Standard and are covered by other standards and regulations. However, information given in this European Standard may be of assistance in meeting the requirements of these standards and regulations.

  • Amendment
    49 pages
    English language
    e-Library read for
    ×1 day

This document specifies an analysing methodology for protecting potable water in potable water installations within and outside buildings but within premises from the risk of pollution by backflow of non-potable water and gives recommendations on the design, risk analysis, backflow prevention devices and their installation methods (see Figure 1 and Figure 2).
This methodology is also intended to be used outside premises for all water systems connected to a potable water distribution system up to and including the point of use (see Figure 3).
The product standards for the specific backflow prevention devices or arrangements are intended to be used in conjunction with this document. For the development of new devices or systems, this document is intended to be used as a reference to establish the necessary level of backflow protection.

  • Standard
    67 pages
    English language
    e-Library read for
    ×1 day

This document specifies an analysing methodology for protecting potable water in potable water installations within and outside buildings but within premises from the risk of pollution by backflow of non-potable water and gives recommendations on the design, risk analysis, backflow prevention devices and their installation methods (see Figure 1 and Figure 2).
This methodology is also intended to be used outside premises for all water systems connected to a potable water distribution system up to and including the point of use (see Figure 3).
The product standards for the specific backflow prevention devices or arrangements are intended to be used in conjunction with this document. For the development of new devices or systems, this document is intended to be used as a reference to establish the necessary level of backflow protection.

  • Standard
    67 pages
    English language
    e-Library read for
    ×1 day

IEC TS 63427:2026 provides principles and technical requirements for the adjustment potential of demand side resources in demand side management. Demand side resources include dispatchable loads, electrical energy storage, grid-connected microgrids, and distributed energy resources, which are connected to power distribution systems and capable of adjusting their operating state and exchanging information with grid control systems. It includes the DSR characteristics, system requirements, data preparation and evaluation process.
The adjustments of demand side resources can be subject to relevant local regulations or specifications. Electricity market mechanisms, user behaviour and data privacy are excluded from the scope of this document.

  • Technical specification
    27 pages
    English language
    sale 15% off

This document specifies the heating condition, method of test and criteria for the evaluation of the ability of a penetration sealing system to maintain the integrity and insulation of a fire-separating element at the position at which it has been penetrated. This document assesses: the effect of such penetrations on the integrity and insulation performance of the element concerned, the integrity and insulation performance of the penetration sealing system, and the insulation performance of the penetrating service or services, and where appropriate, the integrity failure of a service. NOTE 1 Optional water and air leakage tests are included in Annex A. NOTE 2 Explanatory notes are included in Annex B.

  • Standard
    27 pages
    English language
    sale 15% off

This document specifies for passenger lifts and goods passenger lifts:
the verification of door locking devices;
the verification of safety gears;
the verification of overspeed governors;
the verification of buffers;
the verification of safety circuits and SIL-rated circuits;
the verification of ascending car overspeed protection means;
the verification of unintended car movement protection means;
the verification of rupture valves and one-way restrictors;
the verification of suspension and compensation means;
the discard criteria for suspension means and sheaves;
the calculation of guide rails;
the calculation of rams, cylinders, rigid pipes and fittings;
the evaluation of the traction;
the evaluation of the safety factor on suspension means;
the pendulum shock tests;
the fault exclusion for electric and electronic components;
the design rules for SIL-rated circuits.
This document is not applicable to passenger lifts, goods passenger lifts or lift components, which are installed or manufactured before the date of its publication.

  • Draft
    123 pages
    English language
    e-Library read for
    ×1 day

This document specifies the safety rules for lifts permanently serving buildings and constructions and intended for the transport of persons or persons and goods. It applies to traction lifts, positive drive lifts and hydraulic lifts that:
serve specific levels; and
have a rated speed exceeding 0,15 m/s; and
have an enclosed car; and
move along guide rails inclined not more than 15° to the vertical; and
    are indoor or weather-protected.
This document also applies to the electrical equipment of these lifts including the lighting and socket outlets in the well.
This document specifies safety rules related to:
persons to be safeguarded:
users, including passengers, maintenance and inspection personnel;
persons at the landings and outside of the well, or any machinery space and pulley room, who can be affected by the lift.
property to be safeguarded:
loads in the car;
components of the lift installation;
building in which the lift is installed.
This document does not specify additional requirements for:
lifts serving buildings with requirements for seismic conditions;
lifts serving buildings with requirements for accessibility;
lifts exposed to vandalism;
lifts which can be used for firefighting and evacuation purposes under firefighters control;
lifts which can be used to support faster evacuation of persons with disabilities;
the behaviour of the lift when the control system of the lift receives a recall signal(s) in the event of fire in a building.
This document is not applicable to passenger and goods passenger lifts, which are installed before the date of its publication.

  • Draft
    198 pages
    English language
    e-Library read for
    ×1 day

This document specifies definitions and requirements for solid-wall pipes with or without internal skin and smooth internal and external surfaces extruded from the same compound throughout the wall, fittings and the system of polyethylene (PE) piping systems to be intended for use in non-pressure underground drains and sewers for wastewater.
NOTE 1   Products complying with this document can also be used in non-pressure underground drains and sewers for surface water.
This document is applicable to:
a)   non-pressure drains and sewers, which are intended to be used buried underground outside the building structure, reflected in the marking of products by “U”;
b)   non-pressure drains and sewers, which are intended to be used buried underground both outside (application area code “U”) and within the building structure, reflected in the marking of products by “UD”.
This document specifies test methods referred to in this document and test parameters.
This document is applicable to pipes and fittings with or without an integral socket.
This document covers a range of pipe and fitting sizes, stiffness classes, tolerance classes and gives recommendations concerning colours.
NOTE 2   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
In conjunction with CEN/TS 12666-2 [1] it is applicable to PE pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure drains and sewers.
The fittings can be manufactured by injection moulding or can be fabricated from pipes and/or mouldings.
This document is applicable to PE pipes and fittings for the following types of joints:
—   elastomeric ring seal joints;
—   butt fused joints;
—   electrofusion joints;
—   mechanical joints.
NOTE 3   Pipes, fittings and other components conforming to any of the plastics product standards listed in the Annex C (informative) can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Clause 7 and Table 13.

  • Standard
    40 pages
    English language
    e-Library read for
    ×1 day

Shall be according to EN 15502-2-1:2022+A1:2023, Clause 1 with the following modifications:
Replace:
“This document covers gas-fired central heating boilers from the types C1 up to C(11) and the types B2, B3 and B5:”
By:
“This document covers gas-fired central heating boilers from the types C1, C3 up to C9 and the types B2, B3 and B5 :”
b) is replaced by:
b) that use combustible gases of gas group 4Y at the nominal pressure of 20 mbar;
Appliance category   Pn   Pmin   Pmax
4th family   20   17   25
k) is not applicable.
Add at the end of the list, after k), following:
l) which are fully premixed appliances equipped with a Pneumatic Gas/Air Ratio controller (PGAR) or an Adaptive Combustion Control Function (ACCF) that are intended to be connected to hydrogen gas grids where the quality of the distributed hydrogen gas is likely expected to stay within a Wobbe index range of 42 to 46 MJ/m3.
Replace in the list following
“This document does not cover all the requirements for:”
ab), ag), ah) and al) by:
ab) appliances that are intended to be connected to gas grids where the quality of the distributed hydrogen gas is likely to vary outside the Wobbe index range of 42 to 46 MJ/m3;
ag) C(10) boilers;
ah) C(11) boilers;
al) Partially premixed appliances equipped with an adaptive combustion control function (ACCF).
and add an) and ao);
an) The conversion from natural gas to hydrogen.
ao) The risk of aeration of the gas supply to the appliance.

  • Technical specification
    75 pages
    English language
    e-Library read for
    ×1 day

Shall be according to EN 15502-2-1:2022+A1:2023, Clause 1 with the following modifications:
Replace:
“This document covers gas-fired central heating boilers from the types C1 up to C(11) and the types B2, B3 and B5:”
By:
“This document covers gas-fired central heating boilers from the types C1, C3 up to C9 and the types B2, B3 and B5 :”
b) is replaced by:
b) that use combustible gases of gas group 4Y at the nominal pressure of 20 mbar;
Appliance category   Pn   Pmin   Pmax
4th family   20   17   25
k) is not applicable.
Add at the end of the list, after k), following:
l) which are fully premixed appliances equipped with a Pneumatic Gas/Air Ratio controller (PGAR) or an Adaptive Combustion Control Function (ACCF) that are intended to be connected to hydrogen gas grids where the quality of the distributed hydrogen gas is likely expected to stay within a Wobbe index range of 42 to 46 MJ/m3.
Replace in the list following
“This document does not cover all the requirements for:”
ab), ag), ah) and al) by:
ab) appliances that are intended to be connected to gas grids where the quality of the distributed hydrogen gas is likely to vary outside the Wobbe index range of 42 to 46 MJ/m3;
ag) C(10) boilers;
ah) C(11) boilers;
al) Partially premixed appliances equipped with an adaptive combustion control function (ACCF).
and add an) and ao);
an) The conversion from natural gas to hydrogen.
ao) The risk of aeration of the gas supply to the appliance.

  • Technical specification
    75 pages
    English language
    e-Library read for
    ×1 day

This document gives guidance and requirements for the assessment of conformity of formulations, products and assemblies in accordance with EN 1329-1:2026 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1   A basic test matrix provides an overview of the testing scheme in Annex A, Table A.1.
NOTE 2   If certification is involved, the certification body operating in accordance with EN ISO/IEC 17065[1] and EN ISO/IEC 17020[2] is considered to be competent.

  • Technical specification
    22 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to ventilation systems in commercial kitchens, associated areas and other installations processing foodstuffs intended for commercial use. Kitchens and associated areas are special rooms in which meals are prepared, where tableware and equipment are washed and cleaned, food is stored, and food waste areas.
This document specifies requirements and gives recommendations for the configuration, installation, testing, maintenance and safety of fixed kitchen fire extinguishing systems within the design of commercial kitchens in buildings. It is applicable for fire extinguishing systems providing appliance-specific protection as well as overlapping zone protection.
This document provides the guidelines to install fixed fire extinguishing systems to protect against grease fires on the cooking appliances in the extract ventilation system. This document includes recommendations for the certification of system hardware, as well as design, installation and maintenance of the system.
NOTE   It is possible that there are additional or alternative local national regulations on installation, appliance requirements and inspection, maintenance and operation.
This document is applicable to kitchen ventilation systems excluding those in domestic kitchens.

  • Standard
    14 pages
    English language
    e-Library read for
    ×1 day

This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the piping system of unplasticized poly(vinyl chloride) (PVC-U) intended for soil and waste discharge applications (low and high temperature)
-   above ground inside the building, or outside buildings fixed onto the wall; which is reflected in the marking by “B”;
-   for both inside buildings and buried in ground within the building structure, which is reflected in the marking by “BD”. This intended use is only applicable for components with nominal outside diameters equal to or greater than 75 mm.
NOTE 1   Multilayer pipes with different formulations throughout the wall and foamed core pipes are covered by EN 1453-1[1].
PVC-U pipes, fittings and the system complying with this document are also suitable for the following purposes:
-   ventilating part of the pipework in association with discharge applications;
-   rainwater pipework within the building structure.
This document covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours.
Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 26.
NOTE 2   EN 476[2] specifies the general requirements for components used in discharge pipes, drains and sewers for gravity systems. Pipes and fittings conforming to EN 1329-1 fully meet the EN 476 requirements.

  • Standard
    48 pages
    English language
    e-Library read for
    ×1 day

This document specifies definitions, principles of construction (but not dimensions) and design, requirements on performance and operation as well as methods for testing the performance of adjustable chemical dosing systems for conditioning water intended for human consumption inside buildings (see [1]) which are permanently connected to the mains supply.

  • Standard
    18 pages
    English language
    e-Library read for
    ×1 day

This document specifies a procedure for obtaining a migration water to determine odour, flavour, colour and turbidity for products made from organic materials intended to come in contact with water for human consumption (drinking water) and used in piping and storage systems. Such products include pipes, tanks, reservoirs, fittings, ancillaries and their coatings both for site applied and factory-made products.
This document is applicable to products to be used under various conditions for the transport, storage and distribution of water intended for human consumption and raw water used for the manufacture of water intended for human consumption.
This document specifies a test method comprising a set of procedures. The use may be dependent on the relevant national regulations and/or the Commission Implementing Decision (EU) 2024/368.

  • Standard
    27 pages
    English language
    e-Library read for
    ×1 day

This document specifies definitions and requirements for solid-wall pipes with or without internal skin and smooth internal and external surfaces extruded from the same compound throughout the wall, fittings and the system of polyethylene (PE) piping systems to be intended for use in non-pressure underground drains and sewers for wastewater.
NOTE 1   Products complying with this document can also be used in non-pressure underground drains and sewers for surface water.
This document is applicable to:
a)   non-pressure drains and sewers, which are intended to be used buried underground outside the building structure, reflected in the marking of products by “U”;
b)   non-pressure drains and sewers, which are intended to be used buried underground both outside (application area code “U”) and within the building structure, reflected in the marking of products by “UD”.
This document specifies test methods referred to in this document and test parameters.
This document is applicable to pipes and fittings with or without an integral socket.
This document covers a range of pipe and fitting sizes, stiffness classes, tolerance classes and gives recommendations concerning colours.
NOTE 2   It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
In conjunction with CEN/TS 12666-2 [1] it is applicable to PE pipes and fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for buried piping systems for non-pressure drains and sewers.
The fittings can be manufactured by injection moulding or can be fabricated from pipes and/or mouldings.
This document is applicable to PE pipes and fittings for the following types of joints:
—   elastomeric ring seal joints;
—   butt fused joints;
—   electrofusion joints;
—   mechanical joints.
NOTE 3   Pipes, fittings and other components conforming to any of the plastics product standards listed in the Annex C (informative) can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Clause 7 and Table 13.

  • Standard
    40 pages
    English language
    e-Library read for
    ×1 day

This document specifies the requirements for solid wall pipes with smooth internal and external surfaces, extruded from the same formulation throughout the wall, fittings and the piping system of unplasticized poly(vinyl chloride) (PVC-U) intended for soil and waste discharge applications (low and high temperature)
-   above ground inside the building, or outside buildings fixed onto the wall; which is reflected in the marking by “B”;
-   for both inside buildings and buried in ground within the building structure, which is reflected in the marking by “BD”. This intended use is only applicable for components with nominal outside diameters equal to or greater than 75 mm.
NOTE 1   Multilayer pipes with different formulations throughout the wall and foamed core pipes are covered by EN 1453-1[1].
PVC-U pipes, fittings and the system complying with this document are also suitable for the following purposes:
-   ventilating part of the pipework in association with discharge applications;
-   rainwater pipework within the building structure.
This document covers a range of nominal sizes, a range of pipes and fittings series and gives recommendations concerning colours.
Pipes, fittings and other components conforming to any of the plastics product standards listed in Annex B can be used with pipes and fittings conforming to this document, provided they conform to the requirements for joint dimensions given in Clause 7 and to the requirements of Table 26.
NOTE 2   EN 476[2] specifies the general requirements for components used in discharge pipes, drains and sewers for gravity systems. Pipes and fittings conforming to EN 1329-1 fully meet the EN 476 requirements.

  • Standard
    48 pages
    English language
    e-Library read for
    ×1 day

This document gives guidance and requirements for the assessment of conformity of formulations, products and assemblies in accordance with EN 1329-1:2026 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
NOTE 1   A basic test matrix provides an overview of the testing scheme in Annex A, Table A.1.
NOTE 2   If certification is involved, the certification body operating in accordance with EN ISO/IEC 17065[1] and EN ISO/IEC 17020[2] is considered to be competent.

  • Technical specification
    22 pages
    English language
    e-Library read for
    ×1 day

This document specifies general construction, performance and material requirements for PN 10 thermostatic mixing valves (TMV) and includes test methods for the verification of mixed water temperature performance at the point of use below 45 °C. This does not exclude the selection of higher temperatures where available. When these devices are used to provide anti-scald protection for children, elderly and disabled persons the mixed water temperature shall be set at a suitable temperature (body temperature - 38 °C). In particular children are at risk to scalding at lower temperatures than adults. This does not obviate the need for supervision of young children.
It applies to valves intended for use on sanitary appliances in kitchens, washrooms (incl. all rooms with sanitary tapware, e.g. toilet and cloakrooms) and bathrooms operating under the conditions specified in Table 1.
This document allows TMVs to supply a single outlet or a small number of outlets in a “domestic” application (e.g. one valve, controlling a shower, bath, basin and/or, bidet), excluding valves specifically designed for supplying a large number of outlets (i.e. for institutional use).
The tests described are type tests (laboratory tests) and not quality control tests carried out during manufacture.

  • Standard
    57 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to flushing valves for WCs and valves for urinals, with automatic hydraulic closure, intended for:
—   WC pans EN 997;
—   single flush urinals EN 13407;
—   siphon acting urinals EN 13407.
It does not apply to no-contact detection valves.
It is intended to specify:
—   marking and identification, physico-chemical, dimensional, leaktightness, pressure behaviour, hydraulic, mechanical endurance and acoustic characteristics of flushing valves for WCs and urinals with automatic closure;
—   test methods used to verify these characteristics;
—   and to determine requirements for the atmospheric interrupter which shall be an integral part of the WC flushing valve.
It is applicable in the following pressure and temperature conditions (see Table 1):
[Table 1 — Conditions of use for tapware]
NOTE   Although this document limits the pressure for WC DN25 and WC DN32 valves till 0,25 MPa (2,5 bar), some European countries have legislation and recommendations for higher pressures.
Health and quality requirements in accordance to European and national legislation for final materials in contact with water intended for human consumption are not covered by this document.

  • Standard
    36 pages
    English language
    e-Library read for
    ×1 day

This document is a collection of interpretations related to the EN 115 series. This document collects interpretations to EN 115-1:2008+A1:2010 and EN 115-1:2017. Interpretations to other standards of the EN 115 series will be added when they are available.
Interpretations aim to improve the understanding of the clause(s) they are referring to and by that facilitating common understanding between manufacturers, installers, notified bodies, inspection bodies and national authorities.
Interpretations do not have the same status as the European standards to which they are related. However, the application of interpretations given to the interested parties confidence that the relevant European standard has not been wrongly applied.

  • Technical specification
    88 pages
    English language
    e-Library read for
    ×1 day

This document specifies definitions, principles of construction (but not dimensions) and design, requirements on performance and operation as well as methods for testing the performance of adjustable chemical dosing systems for conditioning water intended for human consumption inside buildings (see [1]) which are permanently connected to the mains supply.

  • Standard
    18 pages
    English language
    e-Library read for
    ×1 day

IEC 60364-8-82:2022 provides requirements and recommendations that apply to low-voltage electrical installations connected or not to a distribution network able to operate:
- with local power supplies, and/or
- with local storage units,
and that monitors and controls the energy from the locally connected sources delivering it to:
- current-using equipment, and/or
- local storage units, and/or
- distribution networks.
Such electrical installations are designated as prosumer's electrical installations (PEIs). These requirements and recommendations apply to new installations and modifications of existing installations. This document also provides requirements and recommendations for the safe, efficient and correct behaviour of these installations when integrated into a smart grid. Information related to grid interaction to ensure the stability of the electrical system for grid connected PEIs is given in Annex B. This document covers the requirements related to stability of islanded and stand-alone PEIs. This first edition cancels and replaces IEC 60364-8-2 published in 2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to IEC 60364­-8-­2:2018:
a) the vocabulary and concepts have been aligned as much as possible with those used by TC 8 and SC 8B, taking notably into account the IEC 62898 and IEC 62786 series, still respecting the installers mindset (installers being the first users of the IEC 60364 series and being used to only refer to the IEC 60364 series);
b) the type of system earthing and the change of type of system earthing (sequencing) when there is a change of mode of the prosuming installation, have been clarified;
c) the conditions of connection and disconnection from the DSO network have also been described, both from the safety point of view and the proper functioning point of view;
d) additional requirements have been introduced;
e) the figures have been updated;
f) a new normative Annex D on single dwelling or similar application islandable PEIs has been added;
g) the numbering has also been reviewed to follow the updated numbering system of the IEC 60364 series, in line with the IEC Directives and compatible with Parts 7.

  • Standard
    376 pages
    English language
    sale 15% off
  • Standard
    146 pages
    English and French language
    sale 15% off

IEC TS 63222‑4:2026 specifies the requirements of the models, methods and procedures for harmonic analysis on the public electric power network. This document is applicable to harmonic analysis up to 40th harmonic at high, medium and low voltage of the public electric power network with nominal frequency of 50 Hz or 60 Hz.

  • Technical specification
    50 pages
    English language
    sale 15% off

This document specifies functional requirements for the design, construction, testing, commissioning/decommissioning, operation, maintenance and, where appropriate, calibration, together with suitable documented provisions for all new gas measuring systems and any major changes of existing systems.
This document also specifies accuracy classes of measuring systems and thresholds applicable to these classes. Demonstration of compliance is achieved through the selection, installation and operation of appropriate measurement instruments, together with suitable documented provisions for calculations. Examples of demonstration of compliance are provided for each accuracy class; however, they are not prescriptive solutions.
This document is applicable for gases of the 2nd family as classified in EN 437. It is also applicable for treated non-conventional combustible gases complying with EN 437 and for which a detailed technical evaluation of the functional requirements (such as injected biomethane) is performed ensuring there are no other constituents or properties of the gases that can affect the metrological and physical integrity of the measuring systems. This version mentions technical topics to consider when hydrogen and natural gas / hydrogen blends flow through the measuring systems. Blends with a hydrogen content between 20mol% and 98 mol% are not considered by this standard. This document applies to hydrogen with a purity as specified in CEN/TS 17977 for rededicated natural gas systems.
This document can also be used as a guideline for measuring systems for other gases e.g. gaseous CO2 for CCUS.
This document does not apply to for raw or sour gases.
This document does not apply to for gas measurement in CNG filling stations.
This document gives guidelines when designing, installing and operating gas meters with additional functionalities (smart gas meters).
Communication protocols and interfaces for gas meters and remote reading of gas meters are outside the scope of this document and are covered by the appropriate parts of the EN 13757 series. which provide a number of protocols for meter communications. Supervisory control and data acquisition protocols (SCADA) are also not covered by this document.
Unless otherwise specified all pressures used in this document are gauge pressures.
For associated pressure regulating systems the requirements of EN 12186 and/or EN 12279 apply.
For requirements on design, housing, lay-out, materials for components, construction, ventilation, venting and overall safety of gas measuring systems within the scope of this document, the EN 15001 series, EN 12186, EN 12279 and/or EN 1775 apply additionally, where relevant.

  • Standard
    109 pages
    English language
    e-Library read for
    ×1 day

This document specifies general construction, performance and material requirements for PN 10 thermostatic mixing valves (TMV) and includes test methods for the verification of mixed water temperature performance at the point of use below 45 °C. This does not exclude the selection of higher temperatures where available. When these devices are used to provide anti-scald protection for children, elderly and disabled persons, the mixed water temperature needs to be set at a suitable temperature (body temperature approximately 38 °C). In particular children are at risk to scalding at lower temperatures than adults. This does not obviate the need for supervision of young children.
It applies to valves intended for use on sanitary appliances in kitchens, washrooms (incl. all rooms with sanitary tapware, e.g. toilets and cloakrooms) and bath rooms operating under the conditions specified in Table 1.
This document allows TMVs to supply a single outlet or a small number of outlets in a “domestic” application (e.g. one valve controlling a shower, bath, basin and/or bidet), excluding valves specifically designed for supplying a large number of outlets (i.e. for institutional use).
The tests described are type tests (laboratory tests) and not quality control tests carried out during manufacture.
Table 1 - Conditions of use
[...table not reproduced...]

  • Standard
    59 pages
    English language
    e-Library read for
    ×1 day

This document is applicable to flushing valves for WCs and valves for urinals, with automatic hydraulic closure, intended for:
—   WC pans EN 997;
—   single flush urinals EN 13407;
—   siphon acting urinals EN 13407.
It does not apply to no-contact detection valves.
It is intended to specify:
—   marking and identification, physico-chemical, dimensional, leaktightness, pressure behaviour, hydraulic, mechanical endurance and acoustic characteristics of flushing valves for WCs and urinals with automatic closure;
—   test methods used to verify these characteristics;
—   and to determine requirements for the atmospheric interrupter which shall be an integral part of the WC flushing valve.
It is applicable in the following pressure and temperature conditions (see Table 1):
[Table 1 — Conditions of use for tapware]
NOTE   Although this document limits the pressure for WC DN25 and WC DN32 valves till 0,25 MPa (2,5 bar), some European countries have legislation and recommendations for higher pressures.
Health and quality requirements in accordance to European and national legislation for final materials in contact with water intended for human consumption are not covered by this document.

  • Standard
    36 pages
    English language
    e-Library read for
    ×1 day

This document defines the properties of load test dusts used for heating, ventilation and air conditioning (HVAC) air filters as well as air cleaning equipment in laboratories. Test dusts used for evaluation of efficiency performance are not included.

  • Standard
    16 pages
    English language
    e-Library read for
    ×1 day

This document specifies general construction, performance and material requirements for PN 10 thermostatic mixing valves (TMV) and includes test methods for the verification of mixed water temperature performance at the point of use below 45 °C. This does not exclude the selection of higher temperatures where available. When these devices are used to provide anti-scald protection for children, elderly and disabled persons the mixed water temperature shall be set at a suitable temperature (body temperature - 38 °C). In particular children are at risk to scalding at lower temperatures than adults. This does not obviate the need for supervision of young children.
It applies to valves intended for use on sanitary appliances in kitchens, washrooms (incl. all rooms with sanitary tapware, e.g. toilet and cloakrooms) and bathrooms operating under the conditions specified in Table 1.
This document allows TMVs to supply a single outlet or a small number of outlets in a “domestic” application (e.g. one valve, controlling a shower, bath, basin and/or, bidet), excluding valves specifically designed for supplying a large number of outlets (i.e. for institutional use).
The tests described are type tests (laboratory tests) and not quality control tests carried out during manufacture.
Table 1 - Conditions of use

  • Standard
    57 pages
    English language
    e-Library read for
    ×1 day

The standard specifies requirements for appliances for household and similar purposes to prevent the backflow of non-potable water into the water mains. It also specifies requirements for hose sets used for connecting such appliances to the water mains that supply water at a pressure not exceeding 1 MPa.

  • Amendment
    4 pages
    English language
    e-Library read for
    ×1 day

This document specifies the safety rules for lifts permanently serving buildings and constructions and intended for the transport of persons or persons and goods. It applies to traction lifts, positive drive lifts and hydraulic lifts that: serve specific levels; and have a rated speed exceeding 0,15 m/s; and have an enclosed car; and move along guide rails inclined not more than 15° to the vertical; and are indoor or weather-protected. This document also applies to the electrical equipment of these lifts including the lighting and socket outlets in the well. This document specifies safety rules related to: persons to be safeguarded: users, including passengers, maintenance and inspection personnel; persons at the landings and outside of the well, or any machinery space and pulley room, who can be affected by the lift. property to be safeguarded: loads in the car; components of the lift installation; building in which the lift is installed. This document does not specify additional requirements for: lifts serving buildings with requirements for seismic conditions; lifts serving buildings with requirements for accessibility; lifts exposed to vandalism; lifts which can be used for firefighting and evacuation purposes under firefighters control; lifts which can be used to support faster evacuation of persons with disabilities; the behaviour of the lift when the control system of the lift receives a recall signal(s) in the event of fire in a building. This document is not applicable to passenger and goods passenger lifts, which are installed before the date of its publication.

  • Standard
    191 pages
    English language
    sale 15% off
  • Standard
    191 pages
    English language
    sale 15% off
  • Standard
    204 pages
    French language
    sale 15% off
  • Standard
    204 pages
    French language
    sale 15% off

This document specifies for passenger lifts and goods passenger lifts: the verification of door locking devices; the verification of safety gears; the verification of overspeed governors; the verification of buffers; the verification of safety circuits and SIL-rated circuits; the verification of ascending car overspeed protection means; the verification of unintended car movement protection means; the verification of rupture valves and one-way restrictors; the verification of suspension and compensation means; the discard criteria for suspension means and sheaves; the calculation of guide rails; the calculation of rams, cylinders, rigid pipes and fittings; the evaluation of the traction; the evaluation of the safety factor on suspension means; the pendulum shock tests; the fault exclusion for electric and electronic components; the design rules for SIL-rated circuits. This document is not applicable to passenger lifts, goods passenger lifts or lift components, which are installed or manufactured before the date of its publication.

  • Standard
    110 pages
    English language
    sale 15% off
  • Standard
    118 pages
    French language
    sale 15% off
  • Standard
    118 pages
    French language
    sale 15% off

1.1   This document specifies the safety rules for the construction and installation of permanently installed service lifts, with traction, positive, or hydraulic drive, serving defined landing levels, having a carrier the interior of which is regarded as inaccessible to persons on account of its dimensions and means of construction, suspended by ropes or chains or jack and moving between rigid guide rails inclined not more than 15° to the vertical.
This document covers service lifts with rated load not exceeding 300 kg and not intended to transport persons.
1.2   This document does not cover:
a)   service lifts with drives other than those stated in 1.1;
b)   services lifts having carrier with dimensions that exceed:
1)   for floor area, 1,0 m2;
2)   for depth, 1,0 m;
3)   for height, 1,20 m. The height is not limited if the carrier comprises several permanent compartments, each of which satisfies the above dimensions.
c)   lifting appliances, such as paternosters, mines lifts, theatrical lifts, appliances with automatic caging, skips and hoists for building and public works sites, ships hoists, platforms for exploration or drilling at sea, construction and maintenance appliances;
d)   safety during operations of transport, erection, repairs and dismantling of service lifts;
e)   use of glass for the walls of the well, for the carrier and for the landing doors including their vision panels;
f)   hydraulic service lifts where the setting of the pressure relief valve exceeds 50 MPa;
g)   any form of radiation except EMC (see 4.10.1.1.3);
h)   installation in potentially explosive atmosphere, extreme climate conditions, seismic conditions, transporting dangerous goods, etc.;
i)   ambient temperature in the well and machinery space(s) lower than +5 °C and higher than +40 °C;
j)   health and safety of animals.
However, this document can usefully be taken as a basis.
Noise and vibrations are not dealt with in this document as they are not considered a significant nor relevant hazard for the actual type of the service lift.
Fire propagation is not dealt with in this document.
1.3   The well is regarded as accessible if the opening giving access have clear dimensions of at least 0,40 m x 0,50 m, and:
a)   the horizontal depth of the well is greater than 1 m, or
b)   the area of the well is greater than 1 m2, or
c)   the maintenance is intended to be carried out from the carrier roof or pit regardless the well dimensions.
1.4   The machinery space is regarded as accessible if:
a)   the door(s)/trapdoor(s) giving access have clear dimensions of at least 0,60 m x 0,60 m, and
b)   the height of the passageway is at least 1,80 m.
NOTE   A door about horizontal when closed is referred to as a trapdoor.
1.5   This document covers the safety requirements for service lifts with rated speeds up to 1 m/s.
1.6   This document is not applicable to service lifts which are installed before the date of its publication as EN.

  • Standard
    120 pages
    English language
    e-Library read for
    ×1 day
  • Standard
    120 pages
    English language
    e-Library read for
    ×1 day

This document specifies general construction, performance and material requirements for PN 10 thermostatic mixing valves (TMV) and includes test methods for the verification of mixed water temperature performance at the point of use below 45 °C. This does not exclude the selection of higher temperatures where available. When these devices are used to provide anti-scald protection for children, elderly and disabled persons, the mixed water temperature needs to be set at a suitable temperature (body temperature approximately 38 °C). In particular children are at risk to scalding at lower temperatures than adults. This does not obviate the need for supervision of young children.
It applies to valves intended for use on sanitary appliances in kitchens, washrooms (incl. all rooms with sanitary tapware, e.g. toilets and cloakrooms) and bath rooms operating under the conditions specified in Table 1.
This document allows TMVs to supply a single outlet or a small number of outlets in a “domestic” application (e.g. one valve controlling a shower, bath, basin and/or bidet), excluding valves specifically designed for supplying a large number of outlets (i.e. for institutional use).
The tests described are type tests (laboratory tests) and not quality control tests carried out during manufacture.
Table 1 - Conditions of use
[...table not reproduced...]

  • Standard
    59 pages
    English language
    e-Library read for
    ×1 day

This document specifies the requirements and test methods for rigid or semi-rigid non-metallic ductwork which are used for ventilation and air conditioning in buildings and excludes flexible ducts and ductwork made from insulation duct board.
The specified test methods are under laboratory conditions and exclude on-site tests.

  • Standard
    25 pages
    English language
    e-Library read for
    ×1 day

The standard specifies requirements for appliances for household and similar purposes to prevent the backflow of non-potable water into the water mains. It also specifies requirements for hose sets used for connecting such appliances to the water mains that supply water at a pressure not exceeding 1 MPa.

  • Amendment
    4 pages
    English language
    e-Library read for
    ×1 day

This document specifies requirements and test methods for pipes and fittings which are part of piping systems for the rehabilitation of non-pressure underground drains and sewers.
NOTE            It is not applicable to use of PVC-U material for rehabilitation of pipes under pressure.
It is applicable to unplasticized poly (vinyl chloride) (PVC-U) pipes, fittings and assemblies, as manufactured and as installed with service temperature not exceeding 35 °C. It is not applicable to the existing pipeline.
This document is applicable to the renovation technique family “lining with close-fit pipes”.

  • Standard
    30 pages
    English language
    e-Library read for
    ×1 day

This document specifies requirements and test methods for pipes and fittings which are part of piping systems for the rehabilitation, by means of renovation and trenchless replacement, of underground non-pressure and pressure drains and sewers and water supply networks, which transport water intended for human consumption, including raw water pipelines.
It is applicable to polyethylene (PE) pipes, fittings and assemblies, as manufactured and as installed. It is not applicable to the existing pipeline.
It is applicable to the following technique families for renovation, intended to be used at an operating temperature of 20 °C as the reference temperature:
lining with continuous pipes;
lining with close-fit pipes.
This document is applicable to the following technique families for trenchless replacement, intended to be used at an operating temperature of 20 °C as the reference temperature:
pipe bursting and pipe extraction;
horizontal directional drilling and impact moling.
NOTE            For applications operating at constant temperatures greater than 20 °C and up to 40 °C, see ISO 4427-1:2019, Annex A.
When used with lining with continuous pipes, lining with close-fit pipes and trenchless replacement technique families, this document is applicable to:
PE solid wall single layered pipes (nominal outside diameter, dn), including any identification stripes;
PE pipes with co-extruded layers on either or both the outside and inside of the pipe (total outside diameter, dn), as specified in Annex D, where all layers have the same MRS rating.
Furthermore, when used with lining with continuous pipes and trenchless replacement this document is applicable to:
PE coated pipes (outside diameter, dn) having a peelable, contiguous, thermoplastics additional layer on the outside of the pipe (“coated pipe”), as specified in Annex D.
This document is applicable to jointing by means of butt fusion and electrofusion and to fabricated and injection-moulded fittings and mechanical connections of PE.

  • Standard
    54 pages
    English language
    e-Library read for
    ×1 day

Loading...