(Main)Heat meters - Part 4: Pattern approval tests
Heat meters - Part 4: Pattern approval tests
This European Standard specifies pattern approval tests and applies to heat meters, that is to instruments intended for measuring the heat which, in a heat-exchange circuit, is absorbed (cooling) or given up (heating) by a liquid called the heat-conveying liquid. The heat meter indicates the quantity of heat in legal units. Electrical safety requirements are not covered by this European Standard. Pressure safety requirements are not covered by this European Standard. Surface mounted temperature sensors are not covered by this European Standard. This standard covers meters for closed systems only, where the differential pressure over the thermal load is limited.
Wärmezähler - Teil 4: Prüfungen für die Bauartzulassung
Diese Europäische Norm legt Prüfungen für die Bauartzulassungen für Wärmezähler fest. Wärmezähler sind Geräte, die dazu dienen, die Energiemenge zu messen, die in einem Wärmetauscher¬kreislauf durch eine als Wärmeträgerflüssigkeit bezeichnete Flüssigkeit aufgenommen (Kühlen) oder abge¬geben (Heizen) wird. Der Wärmezähler zeigt die Wärmemenge in gesetzlichen Einheiten an.
Elektrische Sicherheitsanforderungen werden in dieser Europäischen Norm nicht behandelt.
Den Druck betreffende Sicherheitsanforderungen werden in dieser Europäischen Norm nicht behandelt.
Oberflächenmontierte Temperaturfühler werden in dieser Europäischen Norm nicht behandelt.
Die vorliegende Norm behandelt ausschließlich Zähler für geschlossene Systeme, in denen der Differenz-druck am Wärmeübertrager begrenzt ist.
Compteurs d'énergie thermique - Partie 4: Essais en vue de l'approbation de modèle
La présente Norme européenne spécifie les essais en vue de l'approbation de modèle pour les compteurs d'énergie thermique. Les compteurs d'énergie thermique sont des instruments destinés à mesurer l'énergie thermique qui, dans un circuit d'échange thermique, est absorbée (refroidissement) ou cédée (chauffage) par un liquide appelé « liquide caloporteur ». Le compteur d'énergie thermique fournit la quantité d'énergie thermique en unités de mesure légales.
La présente Norme européenne ne traite pas des prescriptions de sécurité électrique.
La présente Norme européenne ne traite pas des prescriptions de sécurité relative à la pression.
La présente Norme européenne ne traite pas des sondes de température montées en surface.
La présente norme couvre les compteurs pour les systèmes fermés uniquement, où la pression différentielle dans la charge thermique est limitée.
Merilniki toplote - 4. del: Preskusi za odobritev tipa
Ta evropski standard določa preskuse za odobritev tipa in se uporablja za toplotne števce, tj. instrumente, ki so namenjeni za merjenje toplote, ki jo v krogotoku toplotne izmenjave absorbira (hlajenje) ali oddaja (ogrevanje) tekočina, imenovana tekočina za prenos toplote. Toplotni števec podaja toploto v predpisanih enotah. Ta evropski standard ne zajema električnih varnostnih zahtev. Ta evropski standard ne zajema tlačnih varnostnih zahtev. Ta evropski standard ne zajema površinsko nameščenih senzorjev temperature. Ta standard zajema samo števce za zaprte sisteme, kjer je diferencialni tlak nad toplotno obremenitvijo omejen.
General Information
Relations
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Merilniki toplote - 4. del: Preskusi za odobritev tipaWärmezähler - Teil 4: Prüfungen für die BauartzulassungCompteurs d'énergie thermique - Partie 4: Essais en vue de l'approbation de modèleHeat meters - Part 4: Pattern approval tests17.200.10Toplota. KalorimetrijaHeat. CalorimetryICS:Ta slovenski standard je istoveten z:EN 1434-4:2015SIST EN 1434-4:2016en,fr,de01-januar-2016SIST EN 1434-4:2016SLOVENSKI
STANDARDSIST EN 1434-4:2007/AC:2007SIST EN 1434-4:20071DGRPHãþD
SIST EN 1434-4:2016
EUROPEAN STANDARD NORME EUROPÉENNE EUROPÄISCHE NORM
EN 1434-4
November
t r s w ICS
s yä t r rä s r Supersedes EN
s v u væ vã t r r yEnglish Version
Heat meters æ Part
vã Pattern approval tests Compteurs d 5énergie thermique æ Partie
vã Essais en vue de l 5approbation de modèle
Wärmezähler æ Teil
vã Prüfungen für die Bauartzulassung This European Standard was approved by CEN on
w September
t r s wä
egulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterationä Upætoædate lists and bibliographical references concerning such national standards may be obtained on application to the CENæCENELEC Management Centre or to any CEN memberä
translation under the responsibility of a CEN member into its own language and notified to the CENæCENELEC Management Centre has the same status as the official versionsä
CEN members are the national standards bodies of Austriaá Belgiumá Bulgariaá Croatiaá Cyprusá Czech Republicá Denmarká Estoniaá Finlandá Former Yugoslav Republic of Macedoniaá Franceá Germanyá Greeceá Hungaryá Icelandá Irelandá Italyá Latviaá Lithuaniaá Luxembourgá Maltaá Netherlandsá Norwayá Polandá Portugalá Romaniaá Slovakiaá Sloveniaá Spainá Swedená Switzerlandá Turkey and United Kingdomä
EUROPEAN COMMITTEE FOR STANDARDIZATION COMITÉ EUROPÉEN DE NORMALISATION EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre:
Avenue Marnix 17,
B-1000 Brussels
9
t r s w CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Membersä Refä Noä EN
s v u væ vã t r s w ESIST EN 1434-4:2016
EN 1434-4:2015 (E) 2 Contents Page European foreword . 4 1 Scope . 6 2 Normative references . 6 3 Terms and definitions . 7 4 General . 7 5 Requirements . 7 6 Specification of operating conditions . 7 6.1 Rated operating conditions . 7 6.2 Reference conditions . 7 6.3 Reference values for the measurand, RVM . 8 7 Tests and measurements . 8 7.1 General . 8 7.2 Test programme . 9 7.3 Uncertainty of test equipment and influences of EUT . 11 7.4 Performance tests . 11 7.5 Dry heat . 16 7.6 Cold . 17 7.7 Static deviations in supply voltage . 18 7.8 Durability test. 19 7.9 Damp heat . 22 7.10 Short time mains voltage reduction . 24 7.11 Electrical transients . 24 7.12 Electromagnetic field . 26 7.13 Electromagnetic field specifically caused by digital radio equipment . 27 7.14 Radio frequency amplitude modulated . 28 7.15 Electrostatic discharge . 30 7.16 Static magnetic field (fraud protection) . 30 7.17 Mains frequency magnetic field . 31 7.18 Internal pressure . 31 7.19 Pressure loss . 31 7.20 Electromagnetic emission . 32 7.21 24 h interruption in the mains power supply voltage . 32 7.22 Flow disturbances . 33 7.23 Vibration/mechanical shock . 33 8 Documentation . 34 Annex A (informative)
Testing procedure for temperature sensor pairs with pockets and without pockets . 35 A.1 Test set-up . 35 A.2 Test sequence . 37 A.3 Calculations . 37 Annex B (informative)
Checklist for type approvals of heat meters according to EN 1434 . 38 SIST EN 1434-4:2016
EN 1434-4:2015 (E) 3 Annex C (informative)
Criteria for a fully developed flow profile . 52 Annex ZA (informative)
Relationship between this European Standard and the Essential Requirements of EU Directive 2004/22/EC, MID . 53 Bibliography . 54
SIST EN 1434-4:2016
EN 1434-4:2015 (E) 4 European foreword This document (EN 1434-4:2015) has been prepared by Technical Committee CEN/TC 176 “Heat meters”, the secretariat of which is held by SIS. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2016, and conflicting national standards shall be withdrawn at the latest by May 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1434-4:2007. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. EN 1434, Heat meters consists of the following parts: — Part 1: General requirements — Part 2: Constructional requirements — Part 3: Data exchange and interfaces1) — Part 4: Pattern approval tests — Part 5: Initial verification tests — Part 6: Installation, commissioning, operational monitoring and maintenance In comparison to EN 1434-4:2007, the following changes have been made: — metrological requirements for smart metering applications are added; — additional functionalities for smart metering applications are added; — cooling meters are added; — influences of sensors are added; — tests for cooling applications and for fast response meters are added; — test for additional functionalities for smart metering applications, e.g. internal clock, external digital signal, absolute temperature are added; — calculator with single temperature sensor are added;
1) EN 1434-3 is maintained by CEN/TC 294. SIST EN 1434-4:2016
EN 1434-4:2015 (E) 5 — test for communication interfaces, endurance test for flow sensors and accelerated durability test are added; — electromagnetic field caused by digital radio equipment; — static magnetic field; — test procedure for temperature sensor pairs with pockets and without pockets. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. SIST EN 1434-4:2016
EN 1434-4:2015 (E) 6 1 Scope This European Standard specifies pattern approval tests for heat meters. Heat meters are instruments intended for measuring the energy which in a heat-exchange circuit is absorbed (cooling) or given up (heating) by a liquid called the heat-conveying liquid. The heat meter indicates the quantity of heat in legal units. Electrical safety requirements are not covered by this European Standard. Pressure safety requirements are not covered by this European Standard. Surface mounted temperature sensors are not covered by this European Standard. This standard covers meters for closed systems only, where the differential pressure over the thermal load is limited. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1434-1:2015, Heat meters — Part 1: General requirements EN 55022, Information technology equipment — Radio disturbance characteristics — Limits and methods of measurement (CISPR 22:2008) EN 60068-2-1, Environmental testing — Part 2-1: Tests - Test A: Cold (IEC 60068-2-1) EN 60068-2-2, Environmental testing — Part 2-2: Tests - Test B: Dry heat (IEC 60068-2-2) EN 60068-2-30, Environmental testing — Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) (IEC 60068-2-30) EN 60751:2008, Industrial platinum resistance thermometers and platinum temperature sensors (IEC 60751:2008) EN 61000-4-2, Electromagnetic compatibility (EMC) — Part 4-2: Testing and measurement techniques — Electrostatic discharge immunity test (IEC 61000-4-2) EN 61000-4-3, Electromagnetic compatibility (EMC) — Part 4-3: Testing and measurement techniques — Radiated, radio-frequency, electromagnetic field immunity test (IEC 61000-4-3) EN 61000-4-4, Electromagnetic compatibility (EMC) — Part 4-4: Testing and measurement techniques — Electrical fast transient/burst immunity test (IEC 61000-4-4) EN 61000-4-5, Electromagnetic compatibility (EMC) — Part 4-5: Testing and measurement techniques — Section 5: Surge immunity test (IEC 61000-4-5) (IEC 61000-4-5) EN 61000-4-6:2014, Electromagnetic compatibility (EMC) — Part 4-6: Testing and measurement techniques — Immunity to conducted disturbances, induced by radio-frequency fields (IEC 61000-4-6:2013) EN 61000-4-8, Electromagnetic compatibility (EMC) — Part 4-8: Testing and measurement techniques — Power frequency magnetic field immunity test (IEC 61000-4-8) SIST EN 1434-4:2016
EN 1434-4:2015 (E) 7 EN 61000-4-11, Electromagnetic compatibility (EMC) — Part 4-11: Testing and measurement techniques — Voltage dips, short interruptions and voltage variations immunity tests (IEC 61000-4-11) EN ISO 4064-2, Water meters for cold potable water and hot water — Part 2: Test methods (ISO 4064-2) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 1434-1:2015 apply. 4 General The procedure shall ascertain that the pattern conforms to the metrological requirements of this European Standard. In addition to the checking of the documentation (Clause 7) and the comparison of the pattern with the metrological requirements of this European Standard, the tests in Clause 6 shall be performed. It is recommended to use a checklist as in Annex B to report in a standardized way the result of the comparison between the patterns under approval with the essential requirements of this European Standard. 5 Requirements Under normal operating conditions, the error of heat meters or their sub-assemblies shall not exceed the maximum permissible error, MPE specified in EN 1434-1. When heat meters or their sub-assemblies are exposed to disturbances, significant faults shall not occur. 6 Specification of operating conditions 6.1 Rated operating conditions The rated operating conditions are those given in Table 1. Table 1 — Rated operating conditions Environmental class A B C Ambient temperature in °C +5 to +55
«25 to +55 +5 to +55 Relative humidity in % < 93 Mains supply voltage in V 195 V to 253 V Mains frequency fnom ± 2 % Battery voltage The voltage of a battery in service under normal conditions Remote AC supply voltage 12 V to 36 V Remote DC supply voltage 12 V to 42 V Local external DC supply voltage as specified by manufacturer 6.2 Reference conditions Range of ambient temperature: +15 °C to +35 °C SIST EN 1434-4:2016
EN 1434-4:2015 (E) 8 Range of relative humidity: 25 % to 75 % Range of ambient air pressure: 86 kPa to 106 kPa Basic mounting orientation The actual temperature and relative humidity within the specified range shall not vary by more than ± 2,5 K and ± 5 percentage points respectively during the period of one measurement. The reference conditions for a sub-assembly shall be the conditions under which it would operate if it was a part of a combined heat meter. 6.3 Reference values for the measurand, RVM 6.3.1 General For heating/cooling meters the RVM shall be based on the values for the heating range. 6.3.2 Reference values for the measurand, RVM Table 2 — Reference values for heating and cooling
Heating applications Cooling applications Range of temperature difference: (40 ± 2) K
(10 ± 2) K Range of flow rate: (0,7 to 0,75) qp in m3/h (0,7 to 0,75) qp in m3/h Outlet temperature: (50 ± 5) °C (15 ± 5) °C The conditions, mentioned in Table 2, are reference values for a complete heat meter. Reference values for sub-assemblies are the relevant parts of the conditions mentioned in Table 2. Flow rate simulation for the flow sensor electronics is allowed, but testing with water is always preferred. The temperature of the liquid in the flow sensor shall be kept at (50 ± 5) °C or at ambient temperature. The power and signal wires shall be connected. The flow sensor including flow sensor electronics shall be operated at zero flow rate (without low flow cut off device). 7 Tests and measurements 7.1 General Unless otherwise stated in the test specification, the test requirements apply irrespective of the heat meter's environmental class. See EN 1434-1:2015, Clause 10. All measurements shall be carried out under the installation conditions stipulated by the manufacturer for his type of meter (e.g. straight sections of piping upstream and downstream of the meter). For all tests the heat conveying liquid shall be water, unless otherwise specified. The performance test shall be carried out with the specified liquid and the type approval certificate shall include the specification of the liquid to be used for initial verification. If a temperature sensor can be installed in the flow sensor, this shall be done during the performance tests of the flow sensor. Where a filter or strainer is an integral part of the flow sensor, it shall be included at all tests. If the error determined lies outside the MPE, the test shall be repeated twice unless otherwise stated. The test is satisfactory declared if both the arithmetic mean of the result of the three tests and at least two of the test results are within or at the MPE. SIST EN 1434-4:2016
EN 1434-4:2015 (E) 9 Depending on the flow sensor size the tests and measurements to be carried out are described below: For each meter model the test in 7.4, 7.18 and 7.19 can be carried out on a limited number of sizes according to an evaluation by the testing laboratory. This evaluation shall be included in the type testing report. The test in 7.8 shall be carried out only for those sizes of a type for which the highest wear is expected. For dimensions > DN 200, 7.19 shall be carried out at min. For each meter model the following tests shall be carried out on one size only: 7.5, 7.6, 7.7, 7.9, 7.10, 7.11, 7.12, 7.13, 7.14, 7.15, 7.16, 7.17, 7.20, 7.21 and 7.23. Tests of additional energy registers for smart metering functionalities: The accuracy of thermal energy accumulation into the additionally and independently energy registers shall be tested by energy performance tests according to 7.4. NOTE In applications of smart metering, one or both single sensors of the pair are used as additional single sensor. Additional tests for control quantities, the internal clock, external digital signal, single temperature sensors, calculators and calculators with single sensors shall be done according to requirements in EN 1434-1:2015, 5.10. It shall be tested that the specific MPE according to EN 1434-1:2015, 5.10.5 for tolerance quantities, used for threshold activation of additional energy accumulations will be met. The absence of software-interaction between all energy registers shall be proved in accordance with the WELMEC Guide “7.2 Software”, respective latest edition. This shall be done for both directions of energy flow, in cases of delivered and absorbed energy (heat and cooling meter). Each additional register under test shall be activated by the corresponding control quantity. It shall be ascertained that the specific activated register content on display is corresponding to the changes of control quantity, as expected and by at least one totalizer energy increment. By metrological tests the accuracy of generating and processing, the accumulated energy values in dependency on the parameterisation of the corresponding control parameters shall be tested. By checking of the switch-on/off parameters, it shall be ascertained that the control quantity and the values thereof are indicated on display properly. The information on the display shall not deviate from the real measurement with respect to measurement conditions. 7.2 Test programme Samples of a heat meter, or its sub-assemblies, submitted for pattern approval, shall be subject to tests to verify their conformity with Clause 4. Unless otherwise stated, the tests shall be carried out at reference conditions and the samples shall be exposed to the influence factors or disturbances specified for the respective tests, as stated in Table 3. The test sequence and the number of items used shall be either as described in Table 3 or as agreed between the manufacturer and the testing laboratory (assuming four samples, numbered by the testing laboratory). Only one influence quantity shall be applied at a time. If the meter under test (complete, combined or sub-assemblies) has test outputs for quantity of water, temperature difference and/or energy, these outputs can be used to test such parameters. SIST EN 1434-4:2016
EN 1434-4:2015 (E) 10 Table 3 — Test programme for heat meters and their sub-assemblies Test Subclause Exposure Temperature sensor pair Flow sensor Calculating device Complete meter Item number
Influence factors
MPE 7.4 Performance test X X X X 2 MPE 7.5 Dry heat
Xa X X 2 MPE 7.6 Cold
Xa X X 2 MPE 7.7 Static deviations in supply voltage
Xa X X 2
Disturbances
NSFa 7.8 Durability X X
X 4 NSF 7.9.1 7.9.2 Damp heat, cyclic Damp heat, steady-state X Xc Xa Xc X
X X 1 1 NSF 7.10 Short time reduction in supply voltage
X X X 3 NSFa 7.11 Electrical transients
Xa,b Xb X 3 NSFd 7.12 Electromagnetic field
Xa,b Xb X 3 NSFd 7.13 Electromagnetic field – digital radio equipment
Xa,b Xb X 3 NSFd 7.14 Radio frequency, amplitude modulated
Xa,b Xb X 3 NSFa 7.15 Electrostatic discharge
Xa X X 3 NSFd 7.16 Static magnetic field
X X X 3 NSFd 7.17 Mains frequency magnetic field
Xa X X 3 NSFa 7.18 Internal pressure
X
X 1
7.19 Pressure loss
X
X 1
7.20 Electromagnetic emission
Xa Xb X 3 SIST EN 1434-4:2016
EN 1434-4:2015 (E) 11 Test Subclause Exposure Temperature sensor pair Flow sensor Calculating device Complete meter Item number
7.21 24 hrs interruption
X X 3 NSFd 7.22 Flow disturbances
X
X 1 NSFa 7.23 Vibration/ mechanical shock X X X X 2 MPE Maximum permissible error according to EN 1434-1:2015, Clause 9. NSFd No signification fault shall occur during the test. NSFa No signification fault shall occur after the test. X Test to be performed. a Only for flow sensors with electronic devices. b This test shall be done with connected cables. c For cooling for meters / sub-assemblies with at least IP 65. For heating/cooling meters the tests in 7.4 shall cover both functions, the tests in 7.6 and 7.9 shall be carried out using the cooling function, but all other tests shall be carried out using the heating function. (For RVM values see 6.3.) 7.3 Uncertainty of test equipment and influences of EUT Standards, instruments and methods used in pattern approval tests shall suit the purpose, be traceable to more precise standards and be part of a reliable calibration programme. The uncertainties associated with these standards, methods and measuring instruments shall always be known. They shall be calculated with a coverage factor of 2 corresponding to a coverage probability of 95 %. The expanded uncertainties shall either: a) not exceed 1/5 of the maximum permissible errors of the heat meter or the sub-assemblies, or b) if the uncertainty is higher than 1/5 of MPE, the value of the difference between uncertainty and 1/5 MPE shall be subtracted from MPE, to calculate a new reduced MPE. The use of a) is recommended. Uncertainty influences (combination of resolution and repeatability) coming from equipment under test shall not be more than 30 % for the flow sensor, 20 % for the calculator and 60 % for the temperature sensor pair of the MPE of each sub-assembly. 7.4 Performance tests 7.4.1 General The initial intrinsic error shall be determined at least at the conditions stated in 7.4.2, 7.4.3, 7.4.4 and 7.4.5. 7.4.2 Flow sensor 7.4.2.1 General All performance tests shall be carried out three times. SIST EN 1434-4:2016
EN 1434-4:2015 (E) 12 For a meter model with more than one specified mounting orientation, the performance testing shall be performed in the orientation, where the higher influences are expected. Tests of flow sensors shall be done above minimum operation pressure specified by the manufacturer with examination of absence of cavitation. It shall be tested, that the volume and energy registers for billing purposes will not decrement in the case of reverse flow rate. 7.4.2.2 Flow rates Flow rates: 1010%q−, 25%q±, 35%q±, 45%q± and %1005+q where 1sqq= and 5iqq=, 12233445qqqqqqqqK==== where s4iqKq= The test flow rate nearest to 0,7 qp to 0,75 qp shall be changed to be within 0,7 qp to 0,75 qp in order to obtain one point within RVM conditions. Table 4 — Water temperatures
Applications
Heating Cooling Test points All All
a minθ to minθ+ 5) °C (but not less than 10 °C) (15 ± 5) °C
b (50 ± 5) °C (5 ± 1) °C
c (85 ± 5) °C
The water temperature at the heat meter shall not vary by more than 2 K during a measurement. For flow sensors larger than DN 250, testing at water temperature a) only, is considered sufficient if the following conditions are satisfied: — the test results for smaller flow sensors of the same model are inside MPE for all water temperatures; — documentary evidence is given that technological similarity exists between the models tested and the larger sizes applied for. 7.4.2.3 Electromagnetic type flow sensors Electromagnetic type flow sensors shall be tested with water having an electrical conductivity higher than 200
SIST EN 1434-4:2016
EN 1434-4:2015 (E) 13 If the manufacturer has stated a lower permitted conductivity, tests shall also be performed at that conductivity at the flow rates q1 and q5, and at the water temperature a). The conductivity shall be noted in the certificate. If the electronic part of the flow sensor is separated from the sensor head, the type and the maximum length of the connecting cable to the electrodes shall be stated by the manufacturer, be used for the above mentioned low conductivity test and noted in the certificate. 7.4.2.4 Fast response meters For fast response meters the transient behaviour of the flow sensors of size qp
¶ 2,5 m3/h shall be investigated by measuring the total quantity of water delivered in 10 to 15 cycles, consisting of 10 s period at a flow rate of qs and 30 s period at zero flow rate. The duration of start and stop shall be (1 ± 0,2) s. The water temperature shall be as a) in 7.4.2.2. The error shall not exceed the MPE. For a complete or combined meter, the water temperature specified above is the outlet temperature. The temperature difference shall be the maximum obtainable, but shall not exceed 42 K. 7.4.3 Calculator 7.4.3.1 Heating and cooling applications The calculator shall be tested at the following simulated temperatures: Table 5 — Testing temperatures for heating applications Temperature °C Temperature difference K a) ()5min0outletθθ+= min∆Θ, 5, 20, RVM∆Θ b) ()5outletRVMθθ=± min∆Θ, 5, 20, RVM∆Θ, max∆Θa c) ()0max5inletθθ−= 20, RVM∆Θ, max∆Θ a The level corresponding to max∆Θ shall be reduced if needed to be within maxθ. Table 6 — Testing temperatures for cooling applications Temperature °C Temperature difference K a) ()5min0inletθθ+= min∆Θ, 5, RVM∆Θ, max∆Θ b) ()155inletθ=± min∆Θ c) ()0max5outletθθ−= RVM∆Θ, max∆Θ The maximum temperature for these tests shall not exceed max. Tolerances: For all temperature differences: ± 20 %, SIST EN 1434-4:2016
EN 1434-4:2015 (E) 14 except for 20min0%+∆Θ and 0max20%−∆Θ For all test points, the simulated flow rate shall not create a signal exceeding the maximum signal acceptable by the calculator. Additional test for bifunctional meters for change-over systems between heating and cooling: An example for the switching over from heating to cooling register and reversed is given in EN 1434-1:2015, Figure 1. It shall be tested that — heating energy shall only be recorded at
> hc and at inlet > hc; — cooling energy shall only be recorded at
< - hc and at inlet < hc; — no heating and cooling energies shall be recorded between - hc and hc. The general test in this clause shall be performed both for the heating and the cooling function using the correct heat coefficient (depending on installation of the flow sensor in higher respectively lower temperature). 7.4.3.2 Additional functionalities for smart metering applications 7.4.3.2.1 Inter
...