SIST EN 300 019-2-4 V2.2.1:2006
(Main)Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-4: Specification of environmental tests; Stationary use at non-weatherprotected locations
Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-4: Specification of environmental tests; Stationary use at non-weatherprotected locations
The present document specifies test methods and severities for verification of the required resistibility of equipment according to the relevant environmental class. The tests defined in Part 2-4 of this multi-part standard apply to stationary use of equipment at non-weatherprotected locations covering the environmental conditions stated in EN 300 019-1-4 [1].
Okoljski inženiring (EE) – Okoljski pogoji in preskusi vplivov okolja na telekomunikacijsko opremo – 2-4. del: Specifikacija preskusov vplivov okolja – Fiksna uporaba na lokacijah, ki niso zaščitene pred vremenskimi vplivi
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 300 019-2-4 V2.2.1:2006
01-februar-2006
2NROMVNLLQåHQLULQJ((±2NROMVNLSRJRMLLQSUHVNXVLYSOLYRYRNROMDQD
WHOHNRPXQLNDFLMVNRRSUHPR±GHO6SHFLILNDFLMDSUHVNXVRYYSOLYRYRNROMD±
)LNVQDXSRUDEDQDORNDFLMDKNLQLVR]DãþLWHQHSUHGYUHPHQVNLPLYSOLYL
Environmental Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 2-4: Specification of environmental tests; Stationary
use at non-weatherprotected locations
Ta slovenski standard je istoveten z: EN 300 019-2-4 Version 2.2.1
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
SIST EN 300 019-2-4 V2.2.1:2006 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 300 019-2-4 V2.2.1:2006
---------------------- Page: 2 ----------------------
SIST EN 300 019-2-4 V2.2.1:2006
ETSI EN 300 019-2-4 V2.2.1 (2003-03)
European Standard (Telecommunications series)
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2-4: Specification of environmental tests;
Stationary use at non-weatherprotected locations
---------------------- Page: 3 ----------------------
SIST EN 300 019-2-4 V2.2.1:2006
2 ETSI EN 300 019-2-4 V2.2.1 (2003-03)
Reference
REN/EE-01032-2-4
Keywords
environment, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, send your comment to:
editor@etsi.org
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2003.
All rights reserved.
TM TM TM
DECT , PLUGTESTS and UMTS are Trade Marks of ETSI registered for the benefit of its Members.
TM
TIPHON and the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members.
TM
3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.
ETSI
---------------------- Page: 4 ----------------------
SIST EN 300 019-2-4 V2.2.1:2006
3 ETSI EN 300 019-2-4 V2.2.1 (2003-03)
Contents
Intellectual Property Rights.4
Foreword.4
1 Scope.5
2 References.5
3 Environmental test specifications.5
3.1 Specification T 4.1: Non-weatherprotected locations, climatic tests.6
3.2 Specification T 4.1E: Non-weatherprotected locations - extended, climatic tests.8
3.3 Specification T 4.2L: Non-weatherprotected locations – extremely cold, climatic tests.10
3.4 Specification T 4.2H: Non-weatherprotected locations – extremely warm dry, climatic tests.12
3.5 Specification T 4.1, 4.1E, 4.2L and 4.2H: Non-weatherprotected locations - mechanical tests.14
4 Earthquake test specification.15
4.1 Vibration response investigation .15
4.2 Test conditioning.15
5 Notes to tables .17
5.1 General note.17
5.2 Notes to tables 1 to 6 .18
Annex A (informative): Bibliography.20
History .21
ETSI
---------------------- Page: 5 ----------------------
SIST EN 300 019-2-4 V2.2.1:2006
4 ETSI EN 300 019-2-4 V2.2.1 (2003-03)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://webapp.etsi.org/IPR/home.asp).
All published ETSI deliverables shall include information which directs the reader to the above source of information.
Foreword
This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environmental
Engineering (EE).
The present document is part 2, sub-part 4 of a multi-part deliverable covering the classification of environmental
conditions and environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions"; (see note 1)
Part 2: "Specification of environmental tests"; (see note 2)
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations".
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use.
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
National transposition dates
Date of adoption of this EN: 21 March 2003
Date of latest announcement of this EN (doa): 30 June 2003
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 December 2003
Date of withdrawal of any conflicting National Standard (dow): 31 December 2003
ETSI
---------------------- Page: 6 ----------------------
SIST EN 300 019-2-4 V2.2.1:2006
5 ETSI EN 300 019-2-4 V2.2.1 (2003-03)
1 Scope
The present document specifies test methods and severities for verification of the required resistibility of equipment
according to the relevant environmental class.
The tests defined in Part 2-4 of this multi-part standard apply to stationary use of equipment at non-weatherprotected
locations covering the environmental conditions stated in EN 300 019-1-4 [1].
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present
document.
• References are either specific (identified by date of publication and/or edition number or version number) or
non-specific.
• For a specific reference, subsequent revisions do not apply.
• For a non-specific reference, the latest version applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
[1] ETSI EN 300 019-1-4: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-4: Classification of environmental
conditions; Stationary use at non-weatherprotected locations".
[2] IEC 60068-2: "Environmental testing - Part 2: Tests".
[3] ETSI EN 300 019-2-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2-0: Specification of environmental
tests; Introduction".
[4] IEC 60721-3-4: "Classification of environmental conditions - Part 3: Classification of groups of
environmental parameters and their severities - Section 4: Stationary use at non-weatherprotected
locations".
[5] ANSI T1.329-2000: "Network Equipment Earthquake Resistance Standard".
3 Environmental test specifications
The detailed descriptions of the environmental conditions are given in clauses 4 and 5 of EN 300 019-1-4 [1].
EN 300 019-2-0 [3] forms a general overview of Part 2 of the present document.
The equipment under test is assumed to be in its operational state throughout the test conditions described in the present
document unless otherwise stated. The required performance before, during and after the test need to be specified in the
product specification. Input and load conditions of the equipment shall be chosen to obtain full utilization of the
equipment under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where
it shall be minimized.
ETSI
---------------------- Page: 7 ----------------------
SIST EN 300 019-2-4 V2.2.1:2006
6 ETSI EN 300 019-2-4 V2.2.1 (2003-03)
3.1 Specification T 4.1: Non-weatherprotected locations, climatic tests
This specification applies to most of Europe as described in EN 300 019-1-4 [1] (see tables 1).
Table 1: Test specification T 4.1: Stationary use at non-weatherprotected locations-climatic tests
Environmental parameter Environmental Environmental test specification T4.1: Stationary use,
Class 4.1 Non-weatherprotected locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity (see clause 5)
(°C) -33 -33 or -45 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1
Low
Air
High (°C) +40 +40 or +55 16 h IEC 60068-2-2 [2] Bb/Bd: Dry heat 2
temperature
(°C) -10/+40 2 cycles IEC 60068-2-14 [2] Nb: Change of 3
Change
(°C/min) 0,5 0,5 t = 3 h temperature
1
low (%) 15 none 8
high (%) 100 93 10 d IEC 60068-2-56 [2] Cb: Damp heat steady state 4
Relative (°C) +30
condensation yes 5
Humidity
(%) 90-100 2 cycles IEC 60068-2-30 [2] Db: Damp heat, cyclic Variant 1
(°C) +30
3
0,26 none
low (g/m )
Absolute
3
25 6
high (g/m )
low (kPa) 70 none 7
Pressure
high (kPa) 106 none 7
Air
Speed (m/s) 50 none 8
3 2
intensity 6 mm/min IEC 60068-2-18 [2] Rb: Impacting water Method 2.2 9
0,01 m /min 3 min/m or
Rain
90 kPa 15 min
low temperature (°C) +5 none
Water
Other splashing water 10
sources
Icing & yes none 8
frosting
2
1 120 11
Solar
(W/m )
Radiation
2
negligible
Heat
(W/m )
ETSI
---------------------- Page: 8 ----------------------
SIST EN 300 019-2-4 V2.2.1:2006
7 ETSI EN 300 019-2-4 V2.2.1 (2003-03)
Environmental parameter Environmental Environmental test specification T4.1: Stationary use,
Class 4.1 Non-weatherprotected locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity (see clause 5)
3
0,3/1,0 none 12
SO (mg/m )
2
Sulphur
3
0,1/0,5 none 12
HS (mg/m )
2
salt mist sea and road salt none 12
3
0,1/0,3 none 12
Cl (mg/m )
Chlorine
2
Chemically
3
0,1/0,5 none 12
active
HCI (mg/m )
substances
3
0,5/1,0 none 12
NO (mg/m )
x
Nitrogen
3
1,0/3,0 none 12
NH (mg/m )
3
3
0,01/0,03 none 12
Hydrogen fluoride HF
(mg/m )
3
Ozone O 0,05/0,1 none 12
(mg/m )
3
Sedimentation 20 13
Mechanically
2
Dust (mg/(m h))
active
3
5 13
suspension (mg/m )
substances
3
300 13
Sand
(mg/m )
Flora and Micro organisms mould, fungus, etc. none 14
fauna
Rodents, insects rodents, etc. none 14
NOTE 1: none = verification is required only in special cases.
NOTE 2: n = number of note, see clause 5.
ETSI
---------------------- Page: 9 ----------------------
SIST EN 300 019-2-4 V2.2.1:2006
8 ETSI EN 300 019-2-4 V2.2.1 (2003-03)
3.2 Specification T 4.1E: Non-weatherprotected locations - extended, climatic tests
This specification covers most of Europe as described in EN 300 019-1-4 [1] (see tables 2).
Table 2: Test specification T 4.1E: Stationary use at non-weatherprotected locations, extended - climatic tests
Environmental parameter Environmental Environmental test specification T4.1E: Stationary use
Class 4.1E Non-weatherprotected locations - extended
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity (see clause 5)
Low (°C) -45 -45 or -55 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1
Air
High (°C) +45 +45 or +60 16 h IEC 60068-2-2 [2] Bb/Bd: Dry heat 2
temperature
(°C) -10/+45 2 cycles IEC 60068-2-14 [2] Nb: Change of temperature 3
Change
(°C/min) 0,5 0,5 t1 = 3 h
low (%) 8 none 8
high (%) 100 93 10 d IEC 60068-2-56 [2] Cb: Damp heat steady state 4
(°C) +30
Relative
condensation yes 2 cycles IEC 60068-2-30 [2] Db: Damp heat cyclic Variant 1 5
(%) 90–100
Humidity
(°C) +30
3
0,03 none 6
low (g/m )
Absolute
3
30
high (g/m )
low (kPa) 70 none 7
Pressure
high (kPa) 106 none 7
Air
(m/s) 50 none 8
Speed
3 2
intensity 15 mm/min IEC 60068-2-18 [2] Rb: Impacting water Method 2.2 9
0,01 m /min 90 kPa 6 min/m or 30 min
Rain
low temperature (°C) +5 none
Water
Other sources splashing water 10
Icing & frosting yes none 8
2
1 120 11
Solar
(W/m )
Radiation
2
negligible
Heat
(W/m )
ETSI
---------------------- Page: 10 ----------------------
SIST EN 300 019-2-4 V2.2.1:2006
9 ETSI EN 300 019-2-4 V2.2.1 (2003-03)
Environmental parameter Environmental Environmental test specification T4.1E:
Class 4.1E Stationary use
Non-weatherprotected locations - extended
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity (see clause 5)
3
Chemically Sulphur 0,3/1,0 none 12
SO (mg/m )
2
active
3
0,1/0,5 none 12
HS (mg/m )
substances 2
Chlorine salt mist sea and road salt none 12
3
0,1/0,3 none 12
Cl (mg/m )
2
3
0,1/0,5 none 12
HCl (mg/m )
3
Nitrogen 0,5/1,0 none 12
NO (mg/m )
x
3
1,0/3,0 none 12
NH (mg/m )
3
3
Hydrogen fluoride HF 0,01/0,03 none 12
(mg/m )
3
Ozone O 0,05/0,1 none 12
(mg/m )
3
Mechanically Dust Sedimentation 20 13
2
active
(mg/(m h))
substances
Suspension 5 13
3
(mg/m )
3
Sand 300 13
(mg/m )
Flora and Micro organisms mould, fungus, etc. none 14
fauna
Rodents, insects rodents, etc. none 14
NOTE 1: none = verification is required only in special cases.
NOTE 2: n = number of note, see clause 5.
ETSI
---------------------- Page: 11 ----------------------
SIST EN 300 019-2-4 V2.2.1:2006
10 ETSI EN 300 019-2-4 V2.2.1 (2003-03)
3.3 Specification T 4.2L: Non-weatherprotected locations – extremely cold, climatic tests
This specification covers world-wide conditions as described in EN 300 019-1-4 [1] (see tables 3).
Table 3: Test specification T 4.2L: Stationary use at non-weatherprotected locations, extremely cold - climatic tests
Environmental parameter Environmental Environmental test specification T4.2L: Stationary use
Class 4.2L Non-weatherprotected locations – extremely cold
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity (see clause 5)
Low (°C) -65 -65 or -75 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1
Air
High (°C) +35 +35 or +50 16 h IEC 60068-2-2 [2] Bb/Bd: Dry heat 2
temperature
(°C) -10/+45 2 cycles IEC 60068-2-14 [2] Nb: Change of temperature 3
Change
(°C/min) 0,5 0,5 t1 = 3 h
low (%) 20 none 8
High (%) 100 93 10 d IEC 60068-2-56 [2] Cb: Damp heat steady state 4
(°C) +30
Relative
condensation yes 2 cycles IEC 60068-2-30 [2] Db: Damp heat cyclic Variant 1 5
(%) 90 –100
Humidity
(°C) +30
3
0,003 none 6
low (g/m )
Absolute
3
22
high (g/m )
low (kPa) 70 none 7
Press
...