Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-5: Specification of environmental tests; Ground vehicle installations

The present document specifies test methods and severities for the verification of the required resistibility of telecommunication equipment according to the relevant environmental class. The tests in the present document apply to the use of equipment installed permanently or temporarily in ground vehicles and cover the vehicles and the environmental conditions stated in EN 300 019-1-5 [1]. The tests cover installations in vehicles powered by electric motors and combustion engines. Applications in combustion engine compartments are excluded.

Okoljski inženiring (EE) – Okoljski pogoji in preskusi vplivov okolja na telekomunikacijsko opremo – 2-5. del: Specifikacija preskusov vplivov okolja – Inštalacije v kopenskih vozilih

General Information

Status
Published
Publication Date
31-Jan-2006
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Feb-2006
Due Date
01-Feb-2006
Completion Date
01-Feb-2006

Buy Standard

Standard
EN 300 019-2-5 V3.0.0:2006
English language
16 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN 300 019-2-5 V3.0.0:2006
01-februar-2006
Okoljski inženiring (EE) – Okoljski pogoji in preskusi vplivov okolja na
telekomunikacijsko opremo – 2-5. del: Specifikacija preskusov vplivov okolja –
Inštalacije v kopenskih vozilih
Environmental Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 2-5: Specification of environmental tests; Ground
vehicle installations
Ta slovenski standard je istoveten z: EN 300 019-2-5 Version 3.0.0
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
SIST EN 300 019-2-5 V3.0.0:2006 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN 300 019-2-5 V3.0.0:2006

---------------------- Page: 2 ----------------------

SIST EN 300 019-2-5 V3.0.0:2006

ETSI EN 300 019-2-5 V3.0.0 (2002-12)
European Standard (Telecommunications series)


Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2-5: Specification of environmental tests;
Ground vehicle installations

---------------------- Page: 3 ----------------------

SIST EN 300 019-2-5 V3.0.0:2006
 2 ETSI EN 300 019-2-5 V3.0.0 (2002-12)



Reference
REN/EE-01034-2-5
Keywords
environment, mobile, terrestrial, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, send your comment to:
editor@etsi.org
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.

© European Telecommunications Standards Institute 2002.
All rights reserved.

TM TM TM
DECT , PLUGTESTS and UMTS are Trade Marks of ETSI registered for the benefit of its Members.
TM
TIPHON and the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members.
TM
3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.
ETSI

---------------------- Page: 4 ----------------------

SIST EN 300 019-2-5 V3.0.0:2006
 3 ETSI EN 300 019-2-5 V3.0.0 (2002-12)
Contents
Intellectual Property Rights.4
Foreword.4
1 Scope.5
2 References.5
3 Environmental test specifications.5
3.1 Specification T 5.1: Protected installation.6
3.2 Specification T 5.2: Partly protected installation .10
4 Notes to tables .12
4.1 General note.12
4.2 Notes to tables 1 to 3 .12
Annex A (informative): Bibliography.15
History .16

ETSI

---------------------- Page: 5 ----------------------

SIST EN 300 019-2-5 V3.0.0:2006
 4 ETSI EN 300 019-2-5 V3.0.0 (2002-12)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://webapp.etsi.org/IPR/home.asp).
All published ETSI deliverables shall include information which directs the reader to the above source of information.
Foreword
This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environmental
Engineering (EE).
The present document is part 2, sub-part 5 of a multi-part deliverable covering environmental conditions and
environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions";
Part 2: "Specification of environmental tests"
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations".
Part 1 specifies different standardized environmental classes covering climatic and biological conditions, chemically
and mechanically active substances and mechanical conditions during storage, transportation and in use.
Part 2 specifies the recommended test severities and test methods for the different environmental classes.
Part 2-0 forms a general overview of part 2. The present document deals with ground vehicle installations.

National transposition dates
Date of adoption of this EN: 29 November 2002
Date of latest announcement of this EN (doa): 28 February 2003
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 August 2003
Date of withdrawal of any conflicting National Standard (dow): 31 August 2003

ETSI

---------------------- Page: 6 ----------------------

SIST EN 300 019-2-5 V3.0.0:2006
 5 ETSI EN 300 019-2-5 V3.0.0 (2002-12)
1 Scope
The present document specifies test methods and severities for the verification of the required resistibility of
telecommunication equipment according to the relevant environmental class.
The tests in the present document apply to the use of equipment installed permanently or temporarily in ground vehicles
and cover the vehicles and the environmental conditions stated in EN 300 019-1-5 [1].
The tests cover installations in vehicles powered by electric motors and combustion engines. Applications in
combustion engine compartments are excluded.
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present
document.
• References are either specific (identified by date of publication and/or edition number or version number) or
non-specific.
• For a specific reference, subsequent revisions do not apply.
• For a non-specific reference, the latest version applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
[1] ETSI EN 300 019-1-5: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-5: Classification of environmental
conditions; Ground vehicle installations".
[2] IEC 60068-2 (all parts): "Environmental testing - Part 2: Tests".
[3] ETSI ETS 300 019-2-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2-0: Specification of environmental
tests; Introduction".
3 Environmental test specifications
The detailed descriptions of the environmental conditions are given in clauses 4 and 5 of EN 300 019-1-5 [1].
ETS 300 019-2-0 [3] forms a general overview of part 2 of the present document.
The equipment under test is assumed to be in its operational state throughout the test conditions described in this part
unless otherwise stated. The required performance before, during and after the test needs to be specified in the product
specification. Input and load conditions of the equipment shall be chosen to obtain full utilization of the equipment
under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where it shall be
minimized.
ETSI

---------------------- Page: 7 ----------------------

SIST EN 300 019-2-5 V3.0.0:2006
 6 ETSI EN 300 019-2-5 V3.0.0 (2002-12)
3.1 Specification T 5.1: Protected installation
This specification applies to use in weatherprotected heated locations in vehicles which are used in areas with or without well developed road systems depending on the selected
IEC mechanical class. See tables 1, 2 and 2a.
Table 1: Test specification T 5.1: Protected installation - climatic tests
Environmental parameter Environmental Environmental test specification T5.1: Vehicle,
Class 5.1 protected installation
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
low (°C) -25 -25 16 h Ab/Ad: Cold 1
IEC 60068-2-1 [2]
high (°C) +40 a), e) +40 or +55 16 h Bb/Bd: Dry heat 2
IEC 60068-2-2 [2]
Air temperature  (°C) +70 b), c) +70 or +85 16 h Bb/Bd: Dry heat 2
IEC 60068-2-2 [2]
 rapid (°C) -25/+30 none  3a
change (°C) -25/+30 -25/+30 5 cycles Na: Change of 3b
IEC 60068-2-14 [2]
gradual (°C/min) 5 not c) t = 3 h temperature
1
 (°C) -25/+60
(°C/min) 10 c)
 air/water (°C) no not c)
Temperature change air/water (°C) +60/+5 c) none  4
 air/snow (°C) +60/-5 c)
 slow temperature (%) 95 93 96 h Cb: Damp heat, 5
IEC 60068-2-56 [2]
change (°C) +40 +40 steady state
  (%) 95 90-100 2 cycles Db: Damp heat, 6
IEC 60068-2-30 [2]
rapid temperature (°C) -25/+30 not d) +40 cyclic, Variant 2
relative change (%) 95 90-100 2 cycles Db: Damp heat, 6
IEC 60068-2-30 [2]
 (°C) +10/+70 d) +55 cyclic, Variant 2
Humidity low (%) 10 none  8
(°C) +30
3

absolute 60 none  7
rapid temperature (g/m )
+70/+15
change (°C)
Air pressure low (kPa) 70 none  9
speed (m/s) 20 none  8
rain Intensity (mm/min) no
Water other sources velocity (m/s) 0,3 none  8
wetness wet surfaces none  8,12
2
Radiation solar 700   13
(W/m )
2
heat 600   13
(W/m )
ETSI

---------------------- Page: 8 ----------------------

SIST EN 300 019-2-5 V3.0.0:2006
 7 ETSI EN 300 019-2-5 V3.0.0 (2002-12)
Environmental parameter Environmental Environmental test specification T5.1: Vehicle,
Class 5.1 protected installation
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
3
sulphur 0,3/1,0 none  14
SO (mg/m )
2
3
0,1/0,5 none  14
 HS (mg/m )
2
sea salts salt mist none  14

chlorine road salts solid salt, none  14
Chemically salt water
3
active 0,1/0,5 none  14
HCI (mg/m )
3
substance nitrogen 0,5/1,0 none  14
NO (mg/m )
x
3
 1,0/3,0 none  14
NH (mg/m )
3
hydrogen
3
fluoride 0,01/0,03 none 14
HF (mg/m )
3
ozone 0,05/0,1 none  14
O (mg/m )
3
2
Mechanically dust 3,0 none  15
other than cabin (mg/(m h))
active (Sedimentation) 2 1,0 15
cabin only (mg/(m h))
3
0,1 none  15
substances sand
(mg/m )

Flora and micro organism mould, fungus, etc. none  16
Fauna rodents, insects rodents, etc. none  16
 motor no
oil gearbox no
 hydraulic none  17
Contaminating transformer none  17
Electrical engine
fluids fluid brake none  17
compartment only
 cooling none  17
grease none  17
battery electrolyte none  17
fuel no
no: This condition does not occur in this class.
none: Verification is required only in special cases.
NOTES: Number of note, see clause 4.2.
Key: a) Ventilated compartment;
b) Unventilated compartment;
c) Engine compartment;
d) Near refrigerated air conditioning;
e) Outdoor air.

ETSI

---------------------- Page: 9 ----------------------

SIST EN 300 019-2-5 V3.0.0:2006
 8 ETSI EN 300 019-2-5 V3.0.0 (
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.