Quartz crystal controlled oscillators of assessed quality -- Part 3: Standard outlines and lead connections

Specifies the outline dimensions and lead connections for quartz crystal controlled oscillators with lead enclosures.

Quarzoszillatoren mit bewerteter Qualität -- Teil 3: Norm-Gehäusemaße und Anschlussdrähte

Oscillateurs pilotés par quartz sous assurance de la qualité -- Partie 3: Encombrements normalisés et connexions des sorties

Spécifie les encombrements normalisés et les connexions des sorties des oscillateurs à quartz comportant des enveloppes avec sorties.

Quartz crystal controlled oscillators of assessed quality - Part 3: Standard outlines and lead connections (IEC 60679-3:2001)

General Information

Status
Withdrawn
Publication Date
31-Aug-2002
Withdrawal Date
13-Jun-2016
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
14-Jun-2016
Due Date
07-Jul-2016
Completion Date
14-Jun-2016

Relations

Buy Standard

Standard
EN 60679-3:2002
English language
37 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI SIST EN 60679-3:2002
prva izdaja
STANDARD
september 2002
Quartz crystal controlled oscillators of assessed quality - Part 3: Standard outlines
and lead connections (IEC 60679-3:2001)
ICS 31.140 Referenčna številka
SIST EN 60679-3:2002(en)
©  Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljeno

---------------------- Page: 1 ----------------------

EUROPEAN STANDARD EN 60679-3
NORME EUROPÉENNE
EUROPÄISCHE NORM October 2001
ICS 31.140
English version
Quartz crystal controlled oscillators of assessed quality
Part 3: Standard outlines and lead connections
(IEC 60679-3:2001)
Oscillateurs pilotés par quartz sous Quarzoszillatoren mit bewerteter Qualität
assurance de la qualité Teil 3: Norm-Gehäusemaße und
Partie 3: Encombrements normalisés et Anschlussdrähte
connexions des sorties (IEC 60679-3:2001)
(CEI 60679-3:2001)
This European Standard was approved by CENELEC on 2001-10-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands,
Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2001 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60679-3:2001 E

---------------------- Page: 2 ----------------------

EN 60679-3:2001 - 2 -
Foreword
The text of document 49/495/FDIS, future edition 2 of IEC 60679-3, prepared by IEC TC 49,
Piezoelectric and dielectric devices for frequency control and selection, was submitted to the IEC-
CENELEC parallel vote and was approved by CENELEC as EN 60679-3 on 2001-10-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement (dop) 2002-07-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn (dow) 2004-10-01
Annexes designated "normative" are part of the body of the standard.
In this standard, annex A is normative.
__________
Endorsement notice
The text of the International Standard IEC 60679-3:2001 was approved by CENELEC as a European
Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60679-1 NOTE  Harmonized as EN 60679-1:1998 (not modified).
IEC 60679-4 NOTE  Harmonized as EN 60679-4:1998 (not modified).
__________

---------------------- Page: 3 ----------------------

�����
���
�������������� ���
�������
�������������
����������������
��������
��������������
�������
�������������������������������
������������������������������
���������
����� ���������������������������!����
�����������
"��������#���������������������������
�$����������������#��
�������
%�������������������������������������
©������������!��������!�%!���������!���!&����⎯����%’!�("����$ �!�("���!���!&��
�������%$!�������������%�) ��$�������� %���� *�!��!�%!������� �� ��� %$!�� �+� �"��� %�) ��$����� �$’� )�� !�%!������� �!� ��� �/��� ��
��� ����������#�� #���+�!���#��������������%$!�$�����%!�����, $�’� +�!�� �!� )’� $�’� ��$��,� � ���!����� �!� ���"$���$ ,
� ���!���#��� ��� ���$��#��,� ’� ���%!��� $� %"�����%��� ��� �� ��� ����(� %"�����%’��(� $��� ���!�+� �,� 0��"���� %�!�������� ��
���!�+� ��,��$��� -$���!����!������ -������!. 0!����(�+!����"��%�) ��"�!.
����!�$����$ �� ���!����"���$ ����������� 1,�!������2$!��)���3���&$,��0��/�! $��
�� �+$�4�56�����7�7��1�� ���$� 4����$� 8���.�" �����0�)�������"��%499000.���.�"
�����:��;
������������ � ���!����"��#��� ����!�$����$ �
2
:���������
�����!�$����$ � � ���!����"���$ � ����������
������������������������������������
��������������������������������

---------------------- Page: 4 ----------------------

60679-3 © IEC:2001 – 3 –
CONTENTS
Page
FOREWORD . 5
INTRODUCTION .9
Clause
1 Scope .11
2 Guidance for the standardization of outline drawings for frequency control
and selection devices .11
3 Dimensions of crystal oscillator enclosure.15
4 Lead connections.15
5 Designation of crystal oscillator enclosures.15
Specification sheets 1 to 17 . 19 à 63
Annex A (normative) Lead connections of crystal oscillators –
Type CO 01 to CO 24.65
Bibliography.69
Table 1 – Designation of crystal oscillator enclosures .15
Table A.1 – Lead connections of crystal oscillators –Type CO 01 to CO 24 .65

---------------------- Page: 5 ----------------------

60679-3 © IEC:2001 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
QUARTZ CRYSTAL CONTROLLED OSCILLATORS
OF ASSESSED QUALITY –
Part 3: Standard outlines and lead connections
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, the IEC publishes International Standards. Their preparation is
entrusted to technical committees; any IEC National Committee interested in the subject dealt with may
participate in this preparatory work. International, governmental and non-governmental organizations liaising
with the IEC also participate in this preparation. The IEC collaborates closely with the International
Organization for Standardization (ISO) in accordance with conditions determined by agreement between the
two organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an
international consensus of opinion on the relevant subjects since each technical committee has representation
from all interested National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form
of standards, technical specifications, technical reports or guides and they are accepted by the National
Committees in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International
Standards transparently to the maximum extent possible in their national and regional standards. Any
divergence between the IEC Standard and the corresponding national or regional standard shall be clearly
indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject
of patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60679-3 has been prepared by IEC technical committee 49:
Piezoelectric and dielectric devices for frequency control and selection.
The text of this standard is based on the following documents:
FDIS Report on voting
49/495/FDIS 49/510/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This second edition cancels and replaces the first edition published in 1989, the first
supplement (1991) and amendment 1 (1994). This second edition constitutes a technical
revision.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 3.
Annex A forms an integral part of this standard.

---------------------- Page: 6 ----------------------

60679-3 © IEC:2001 – 7 –
IEC 60679 consists of the following parts under the general title: Quartz crystal controlled
oscillators of assessed quality:
– Part 1: Generic specification
– Part 2: Guide to the use of quartz crystal controlled oscillators
– Part 3: Standard outlines and lead connections
– Part 4: Sectional specification – Capability approval
– Part 4-1: Blank detail specification – Capability approval
– Part 5: Sectional specification – Qualification approval
– Part 5-1: Blank detail specification – Qualification approval
The committee has decided that the contents of this publication will remain unchanged until
2006. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.

---------------------- Page: 7 ----------------------

60679-3 © IEC:2001 – 9 –
INTRODUCTION
The first edition of IEC 60679-3 (1989), its amendment and supplement contained 52
enclosure types showing the dimensional and geometrical characteristics of these enclosures.
Since its release, due to progress in technology, many of the enclosures given in the standard
have become obsolete.
Bearing this in mind, technical committee 49 has issued a questionnaire on all outlines
contained in IEC 60679-3. Based on the replies received, technical committee 49 made a
decision at the meeting held in Rotterdam in June 1996 to retain only enclosures which
remained in “wide usage”. These enclosures are specified in the present standard.
The following 25 enclosure types have been deleted from the first edition of 60679-3 (1989)
and its amendment and supplement:
CO 03 A1 CO 04 A1 CO 04 B1 CO 05 A1 CO 06 B. CO 06 C. CO 06 .1
CO 06 .2 CO 07 B. CO 07 C. CO 07 D. CO 10 B1 CO 11 A1 CO 12 A1
CO 13 A1 CO 13 B1 CO 14 A1 CO 15 A1 CO 17 C1 CO 18 A1 CO 18 C1
CO 19 .2 CO 20 A1 CO 23 A1 CO 23 C1

---------------------- Page: 8 ----------------------

60679-3 © IEC:2001 – 11 –
QUARTZ CRYSTAL CONTROLLED OSCILLATORS
OF ASSESSED QUALITY –
Part 3: Standard outlines and lead connections
1 Scope
This part of IEC 60679 specifies the outline dimensions and lead connections for quartz
crystal controlled oscillators with lead enclosures.
2 Guidance for the standardization of outline drawings for frequency control
and selection devices
In order to achieve a uniform presentation of all outline drawings for frequency control and
selection devices, the following guide shall be considered.
2.1 An outline drawing shall show all dimensional and geometrical characteristics of an
enclosure necessary to ensure mechanical interchangeability with all other enclosures of the
same outlines. Enlarged detail view may be used, if necessary.
2.2 The outline drawing shall consist of three parts:
2.2.1 A drawing with dimensional symbols (capital letters) as shown in figure 1 below with
applicable notes, if necessary.
2.2.2 A tabular listing relating the drawing symbols to the actual dimensions. Where
possible, this shall be shown on the same page as the drawing.
2.2.3 An “actual-size” sketch (scale:1:1).
2.3 The outline drawing shall be executed in the third-angle projection.
2.4 The function and identification of the lead connections (termination) shall be determined
by agreement between the supplier and user. They shall not be defined on the outline
drawing.
2.5 Descriptive notes may be used at the bottom of, or adjacent to, the drawing with proper
reference to the body of the drawing.
2.6 All dimensions shall be in millimetres.
2.7 Outline dimensions A, B, C, D and E shall be listed with maximum values only.
2.8 Lead (termination) cross-sectional dimensions shall be listed with minimum and
maximum values. If applicable, nominal dimensions may be added.
2.9 The spacing of the leads (termination) – symbol H – shall be listed with minimum,
nominal and maximum dimensions.

---------------------- Page: 9 ----------------------

60679-3 © IEC:2001 – 13 –
E
D
Actual size
1:1
C
U
L
W
H
B
K
A
IEC  876/01
Dimensions (mm)
Ref. Notes
Min. Nom. Max.
A – – x

B – x
C –– x
D –– x
E –– x
H xxx
K x–x 1
L
x–x
U x– – 2
W x– – 2
NOTE 1….
NOTE 2….
Scale
2:1
Figure 1 – Guidance for outline drawings
                  Sheet -- Date:

---------------------- Page: 10 ----------------------

60679-3 © IEC:2001 – 15 –
2.10 Leads (terminations) for soldering applications shall be specified with the minimum
length dimensions (symbol L) only.
Leads (terminations) for plug-in applications shall be specified with minimum and maximum
length dimensions.
2.11 If leads (terminations) are provided with an undercut, dimensions U and W shall be
listed with minimum dimensions only.
3 Dimensions of crystal oscillator enclosure
The dimensions in this standard apply to the completed quartz crystal controlled oscillators.
Only those dimensions which meet the requirements of the guidance for standardization of
outline drawings are given (see clause 2).
4 Lead connections
Recommendations for the lead connections of quartz crystal controlled oscillators are given in
annex A to this standard. Lead connections shall always be given in the detail specification.
5 Designation of crystal oscillator enclosures
Table 1 – Designation of crystal oscillator enclosures
No. Type Sheet No. Description
1 CO 01 A1 Sheet 1 Plastic enclosure, 4 to 14 lead crystal oscillator outline
CO 02 A1
2 Sheet 2 Metal enclosure, welded, 4 to 18 lead crystal oscillator outline
CO 02 B1
3 CO 05 B1 Sheet 3 Metal enclosure, welded, eight lead crystal oscillator outline
4 CO 06 A1 Sheet 4 Metal enclosure, four lead crystal oscillator outline
5 CO 07 A1 Sheet 5 Metal enclosure, four to seven lead crystal oscillator outline
CO 08 A1
6 CO 08 B1 Sheet 6 Metal enclosure, five lead crystal oscillator outline
CO 08 C1
CO 09 A1
7 Sheet 7 Metal enclosure, five lead crystal oscillator outline
CO 09 B1
8 CO 10 A1 Sheet 8 Metal enclosure, five lead crystal oscillator outline
CO 15 B1
9 Sheet 9 Metal enclosure, five lead crystal oscillator outline
CO 15 C1
CO 16 A1
10 CO 16 B1 Sheet 10 Metal enclosure, four lead crystal oscillator outline
CO 16 C1

---------------------- Page: 11 ----------------------

60679-3 © IEC:2001 – 17 –
Table 1 – Designation of crystal oscillator enclosures (continued)
No. Type Sheet No. Description
CO 17 A1
11 Sheet 11 Metal enclosure, four lead crystal oscillator outline
CO 17 B1
12 CO 18 B1 Sheet 12 Metal enclosure, four lead crystal oscillator outline
CO 19 A1
13 Sheet 13 Metal enclosure, five lead crystal oscillator outline
CO 19 B1
14 CO 21 A1 Sheet 14 Metal enclosure, welded, four lead crystal oscillator outline
Plastic moulded or ceramic, solder-glass sealed eight lead crystal
15 CO 22 A1 Sheet 15
oscillator outline
16 CO 23 B1 Sheet 16 Metal enclosure, welded, eight lead crystal oscillator outline
17 CO 24 A1 Sheet 17 Metal enclosure, four lead crystal oscillator outline

---------------------- Page: 12 ----------------------

60679-3 © IEC:2001 – 19 –
B
A
C
L
Actual size
H H K
H
3 5
4
H
H 2
1
IEC  877/01
Dimensions (mm)
Identity
Ref. Notes
reference
Min. Nom. Max.
A – –  20,83
B – –  13,21
C – –   7,62 CO 01 A. 3
H  14,94  15,24  15,54
1
H   7,32   7,62   7,92
2
H   2,30   2,54   2,70
3
H   2,30   2,54   2,70
4
H   2,30   2,54   2,70
5
K   0,254 –   0,533 2
L   3,05 – – CO 01 .1 3
NOTE 1 An indication shall be provided to locate the position of lead No. 1 (a corner notch is shown on the drawing as
an example).
K K
NOTE 2 Leads may be round, square or rectangular but shall not exceed min and max.
NOTE 3 The complete identity for any oscillator outline is a six digit type number consisting of the basic type number
(four digits) followed by a letter indicating the enclosure height and a number indicating the lead length. The identity
references are given in the table, where a dot indicates the missing information which is given on another line.
CO 01 A1 is therefore the complete identity for this enclosure.
 Plastic enclosure, 4 to 14 lead crystal oscillator Scale
 2:1
 outline – Type CO 01
Sheet 1 Date: 2001-07

---------------------- Page: 13 ----------------------

60679-3 © IEC:2001 – 21 –
C
L
N
K
Actual size
H
1
H
3
H
3
B
H M
2 2
M
1
A
IEC  878/01
Dimensions (mm)
Identity
Ref. Notes
reference
Min. Nom. Max.
A – –  20,70
B – –  13,10
C – –   5,10 CO 02 A.  5
1
C – –   6,60 CO 02 B.  5
2
H  14,94  15,24  15,54
1
H   7,32   7,62   7,92
2
H   2,30   2,54   2,70
3
K   0,40 –   0,53  3
L   5,85 – – CO 02 .1  5
M
1 –  12,20 –  2
M –   4,58 –  2
2
N – –   0,75
Scale
 Metal enclosure, welded, 4 to 18 lead crystal oscillator
2:1
 outline – Type CO 02
Sheet 2 Date: 2001-07

---------------------- Page: 14 ----------------------

60679-3 © IEC:2001 – 23 –
NOTE 1 An indication shall be provided to locate the position of lead No. 1 (a 90° corner is shown on the drawing as an
example).
NOTE 2 If required, insulating standoffs shall be located within corner areas defined in the table by M and M .
1 2
If insulating tape standoffs are used, shaded areas as indicated are preferred and the tape may encircle the leads.
NOTE 3 Leads with solderable finish shall not exceed K .
max
NOTE 4 Ground leads may be created by a brazed or welded joint(s) to the base.
NOTE 5 The complete identity for any oscillator outline is a six digit type number consisting of the basic type number (four
digits) followed by a letter indicating the enclosure height and a number indicating the lead length. The identity references
are given in the table, where a dot indicates the miss
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.