SIST EN 300 019-1-4 V2.1.1:2006
(Main)Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-4: Classification of environmental conditions; Stationary use at non-weatherprotected locations
Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-4: Classification of environmental conditions; Stationary use at non-weatherprotected locations
The purpose of the present document is to define a class of environmental conditions and their severities to which equipment may be exposed. Only severe conditions, which may be harmful to the equipment, are included. The severities specified are those which will have a low probability of being exceeded; generally less than 1 %. The present document applies to equipment mounted for stationary use including periods of erection work, down time, maintenance and repair at non-weatherprotected locations defined in clause 5.
Okoljski inženiring (EE) – Okoljski pogoji in preskusi vplivov okolja na telekomunikacijsko opremo – 1-4. del: Klasifikacija okoljskih pogojev – Fiksna uporaba na lokacijah, ki niso zaščitene pred vremenskimi vplivi
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN 300 019-1-4 V2.1.1:2006
01-februar-2006
2NROMVNLLQåHQLULQJ((±2NROMVNLSRJRMLLQSUHVNXVLYSOLYRYRNROMDQD
WHOHNRPXQLNDFLMVNRRSUHPR±GHO.ODVLILNDFLMDRNROMVNLKSRJRMHY±)LNVQD
XSRUDEDQDORNDFLMDKNLQLVR]DãþLWHQHSUHGYUHPHQVNLPLYSOLYL
Environmental Engineering (EE); Environmental conditions and environmental tests for
telecommunications equipment; Part 1-4: Classification of environmental conditions;
Stationary use at non-weatherprotected locations
Ta slovenski standard je istoveten z: EN 300 019-1-4 Version 2.1.1
ICS:
19.040 Preskušanje v zvezi z Environmental testing
okoljem
33.050.01 Telekomunikacijska Telecommunication terminal
terminalska oprema na equipment in general
splošno
SIST EN 300 019-1-4 V2.1.1:2006 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN 300 019-1-4 V2.1.1:2006
---------------------- Page: 2 ----------------------
SIST EN 300 019-1-4 V2.1.1:2006
ETSI EN 300 019-1-4 V2.1.1 (2003-03)
European Standard (Telecommunications series)
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 1-4: Classification of environmental conditions;
Stationary use at non-weatherprotected locations
---------------------- Page: 3 ----------------------
SIST EN 300 019-1-4 V2.1.1:2006
2 ETSI EN 300 019-1-4 V2.1.1 (2003-03)
Reference
REN/EE-01027-1-4
Keywords
environment, testing, equipment pratice
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88
Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, send your comment to:
editor@etsi.org
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2003.
All rights reserved.
TM TM TM
DECT , PLUGTESTS and UMTS are Trade Marks of ETSI registered for the benefit of its Members.
TM
TIPHON and the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members.
TM
3GPP is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners.
ETSI
---------------------- Page: 4 ----------------------
SIST EN 300 019-1-4 V2.1.1:2006
3 ETSI EN 300 019-1-4 V2.1.1 (2003-03)
Contents
Intellectual Property Rights.4
Foreword.4
1 Scope.5
2 References.5
3 Definitions.6
4 Environmental classes.6
4.1 Class 4.1: Non-weatherprotected locations .7
4.2 Class 4.1E: Non-weatherprotected locations - extended .7
4.3 Class 4.2L: Non-weatherprotected locations - extremely cold.7
4.4 Class 4.2H: Non-weatherprotected locations - extremely warm dry.8
5 Environmental conditions.9
5.1 Climatic conditions.9
5.2 Biological conditions.9
5.3 Chemically active substances .10
5.4 Mechanically active substances.10
5.5 Mechanical conditions.11
5.6 Earthquake conditions.11
Annex A (informative): Bibliography.14
History .15
ETSI
---------------------- Page: 5 ----------------------
SIST EN 300 019-1-4 V2.1.1:2006
4 ETSI EN 300 019-1-4 V2.1.1 (2003-03)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://webapp.etsi.org/IPR/home.asp).
All published ETSI deliverables shall include information which directs the reader to the above source of information.
Foreword
This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environmental
Engineering (EE).
The present document is part 1, sub part 4 of a multi-part deliverable covering the classification of environmental
conditions and environmental tests for telecommunications equipment, as identified below:
Part 1: "Classification of environmental conditions"; (see note 1)
Sub-part 0: "Introduction";
Sub-part 1: "Storage";
Sub-part 2: "Transportation";
Sub-part 3: "Stationary use at weatherprotected locations";
Sub-part 4: "Stationary use at non-weatherprotected locations";
Sub-part 5: "Ground vehicle installations";
Sub-part 6: "Ship environments";
Sub-part 7: "Portable and non-stationary use";
Sub-part 8: "Stationary use at underground locations";
Part 2: "Specification of environmental tests". (see note 2)
NOTE 1: Specifies different standardized environmental classes covering climatic and biological conditions,
chemically and mechanically active substances and mechanical conditions during storage, transportation
and in use. Sub-part 1-0 forms a general overview of part 1.
NOTE 2: Specifies the recommended test severities and test methods for the different environmental classes.
National transposition dates
Date of adoption of this EN: 21 March 2003
Date of latest announcement of this EN (doa): 30 June 2003
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 31 December 2003
Date of withdrawal of any conflicting National Standard (dow): 31 December 2003
ETSI
---------------------- Page: 6 ----------------------
SIST EN 300 019-1-4 V2.1.1:2006
5 ETSI EN 300 019-1-4 V2.1.1 (2003-03)
1 Scope
The purpose of the present document is to define a class of environmental conditions and their severities to which
equipment may be exposed. Only severe conditions, which may be harmful to the equipment, are included. The
severities specified are those which will have a low probability of being exceeded; generally less than 1 %.
The present document applies to equipment mounted for stationary use including periods of erection work, down time,
maintenance and repair at non-weatherprotected locations defined in clause 5.
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present
document.
• References are either specific (identified by date of publication and/or edition number or version number) or
non-specific.
• For a specific reference, subsequent revisions do not apply.
• For a non-specific reference, the latest version applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
[1] IEC 60721-3-4: "Classification of environmental conditions - Part 3: Classification of groups of
environmental parameters and their severities - Section 4: Stationary use at non-weatherprotected
locations".
[2] IEC 60721-2-4: "Classification of environmental conditions - Part 2-4: Environmental conditions
appearing in nature - Solar radiation and temperature".
[3] IEC 60068-2-27: "Environmental testing. Part 2: Tests. Test Ea and guidance: Shock".
[4] IEC 60721-2-6: "Classification of environmental conditions. Part 2: Environmental conditions
appearing in nature - Earthquake vibration and shock".
[5] IEC 60068-3-3: "Environmental testing - Part 3: Guidance. Seismic test methods for equipment".
[6] ETSI EN 300 019-1-3: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-3: Classification of environmental
conditions; Stationary use at weatherprotected locations".
[7] ETSI EN 300 019-2-4: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2-4: Specification of environmental
tests; Stationary use at non-weatherprotected locations".
ETSI
---------------------- Page: 7 ----------------------
SIST EN 300 019-1-4 V2.1.1:2006
6 ETSI EN 300 019-1-4 V2.1.1 (2003-03)
3 Definitions
For the purposes of the present document, the following terms and definitions apply:
absolute humidity: mass of water vapour in grammes which is associated with one cubic metre of dry air in an
air/water vapour mixture
non-weatherprotected location: location at which the equipment is not protected from direct weather influences
relative humidity: ratio of the partial pressure of the water vapour in moist air at a given temperature, to the partial
pressure of the water vapour in saturated air at the same temperature
stationary use: The equipment is mounted firmly on the structure, or on mounting devices, or it is permanently placed
at a certain site. It is not intended for portable use - but short periods of handling during erection works, down time,
maintenance and repair at the location are included.
4 Environmental classes
The classes shown in parentheses, e.g. (4C3), may be selected for special applications.
These classes apply to a non-weatherprotected location.
These classes apply to locations:
- which are directly exposed to an open-air climate, including solar radiation, movement of the surrounding air,
precipitation and water jets; splashing water;
- where mould growth, or attacks by animals but excluding termites, may occur;
- with normal levels of contaminants experienced in urban areas with industrial activities scattered over the
whole area and/or with heavy traffic. It also applies to coastal areas;
NOTE 1: At locations in the immediate neighbourhood of industrial sources with chemical emissions either special
precautions must be taken or a special chemical class must be chosen.
- in areas with sand or dust sources, including urban areas;
NOTE 2: At locations in geographical areas with wind-driven sand or dust in air special precautions must be taken
or a special class for mechanically active substances must be chosen.
- where transmitted vibrations are experienced from machines or passing vehicles. Higher level shocks may be
experienced e.g. from adjacent machines.
NOTE 3: More severe mechanical conditions are to be expected for equipment intended for public use. Special
requirements should be stated for such equipment, e.g. protection against vandalism.
If earthquake conditions can be expected, the conditions stated in clause 5.6 apply.
Two groups of classes are considered:
- Classes 4.1 and 4.1E apply to general climatic conditions - applies to climatic conditions in most of Europe.
- Classes 4.2L and 4.2H apply to extreme climatic conditions. These classes should be considered
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.