Environmental Engineering (EE) - Environmental conditions and environmental tests for telecommunications equipment - Part 2-4: Specification of environmental tests - Stationary use at non-weatherprotected locations

The present document specifies test methods and severities for verification of the required resistibility of equipment according to the relevant environmental class. The tests defined in the present document apply to stationary use of equipment at non-weatherprotected locations covering the environmental conditions stated in EN 300 019-1-4 [1].

Okoljski inženiring (EE) - Okoljski pogoji in preskusi vplivov okolja na telekomunikacijsko opremo - 2-4. del: Specifikacija preskusov vplivov okolja - Fiksna uporaba na lokacijah, ki niso zaščitene pred vremenskimi vplivi

Ta dokument določa preskusne metode in stopnje zahtevnosti za preverjanje zahtevane odpornosti opreme glede na ustrezen okoljski razred. Preskusi, določeni v tem dokumentu, se uporabljajo za fiksno uporabo opreme na lokacijah, ki niso zaščitene pred vremenskimi vplivi, kot določajo okoljski pogoji, določeni v standardu EN 300 019-1-4 [1].

General Information

Status
Published
Public Enquiry End Date
28-Feb-2013
Publication Date
23-Sep-2013
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
02-Sep-2013
Due Date
07-Nov-2013
Completion Date
24-Sep-2013

Buy Standard

Standard
EN 300 019-2-4 V2.3.1:2013
English language
22 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day
Standard
ETSI EN 300 019-2-4 V2.3.1 (2013-06) - Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-4: Specification of environmental tests; Stationary use at non-weatherprotected locations
English language
22 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.SOLYLEnvironmental Engineering (EE) - Environmental conditions and environmental tests for telecommunications equipment - Part 2-4: Specification of environmental tests -
Stationary use at non-weatherprotected locations33.050.01Telekomunikacijska terminalska oprema na splošnoTelecommunication terminal equipment in general19.040Preskušanje v zvezi z okoljemEnvironmental testingICS:Ta slovenski standard je istoveten z:EN 300 019-2-4 Version 2.3.1SIST EN 300 019-2-4 V2.3.1:2013en01-oktober-2013SIST EN 300 019-2-4 V2.3.1:2013SLOVENSKI
STANDARD



SIST EN 300 019-2-4 V2.3.1:2013



ETSI EN 300 019-2-4 V2.3.1 (2013-08) Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-4: Specification of environmental tests; Stationary use at non-weatherprotected locations
European Standard SIST EN 300 019-2-4 V2.3.1:2013



ETSI ETSI EN 300 019-2-4 V2.3.1 (2013-08)2
Reference REN/EE-01049 Keywords environment, testing ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE
Tel.: +33 4 92 94 42 00
Fax: +33 4 93 65 47 16
Siret N° 348 623 562 00017 - NAF 742 C Association à but non lucratif enregistrée à la Sous-Préfecture de Grasse (06) N° 7803/88
Important notice Individual copies of the present document can be downloaded from: http://www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the current status of this and other ETSI documents is available at http://portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http://portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 2013. All rights reserved.
DECTTM, PLUGTESTSTM, UMTSTM and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members. 3GPPTM and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association. SIST EN 300 019-2-4 V2.3.1:2013



ETSI ETSI EN 300 019-2-4 V2.3.1 (2013-08)3 Contents Intellectual Property Rights . 4 Foreword . 4 1 Scope . 5 2 References . 5 2.1 Normative references . 5 2.2 Informative references . 6 3 Environmental test specifications . 6 3.1 Specification T 4.1: Non-weatherprotected locations, climatic tests . 7 3.2 Specification T 4.1E: Non-weatherprotected locations - extended, climatic tests . 9 3.3 Specification T 4.2L: Non-weatherprotected locations – extremely cold, climatic tests . 11 3.4 Specification T 4.2H: Non-weatherprotected locations – extremely warm dry, climatic tests . 13 3.5 Specification T 4.1, 4.1E, 4.2L and 4.2H: Non-weatherprotected locations - mechanical tests . 15 4 Earthquake test specification . 16 4.1 Vibration response investigation . 16 4.2 Test conditioning . 16 5 Notes to tables . 18 5.1 General note . 18 5.2 Notes to tables 1 to 6 . 19 Annex A (informative): Bibliography . 21 History . 22
SIST EN 300 019-2-4 V2.3.1:2013



ETSI ETSI EN 300 019-2-4 V2.3.1 (2013-08)4 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http://ipr.etsi.org). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering (EE). The present document is part 2, sub-part 4 of a multi-part deliverable. Full details of the entire series can be found in part 2, sub-part 0 [i.1].
National transposition dates Date of adoption of this EN: 23 August 2013 Date of latest announcement of this EN (doa): 30 November 2013 Date of latest publication of new National Standard or endorsement of this EN (dop/e):
31 May 2014 Date of withdrawal of any conflicting National Standard (dow): 31 May 2014
SIST EN 300 019-2-4 V2.3.1:2013



ETSI ETSI EN 300 019-2-4 V2.3.1 (2013-08)5 1 Scope The present document specifies test methods and severities for verification of the required resistibility of equipment according to the relevant environmental class. The tests defined in the present document apply to stationary use of equipment at non-weatherprotected locations covering the environmental conditions stated in EN 300 019-1-4 [1]. 2 References References are either specific (identified by date of publication and/or edition number or version number) or non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the reference document (including any amendments) applies. Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference. NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee their long term validity. 2.1 Normative references The following referenced documents are necessary for the application of the present document. [1] ETSI EN 300 019-1-4: "Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 1-4: Classification of environmental conditions; Stationary use at non-weatherprotected locations". [2] IEC 60068-2-1 (03-2007): "Environmental testing, Part 2-1: Tests - Test A: Cold". [3] Void. [4] IEC 60721-3-4: "Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 4: Stationary use at non-weatherprotected locations". [5] ANSI T1.0600329 (2008): "Network Equipment - Earthquake Resistance Standard". [6] Void. [7] IEC 60068-2-2 (07-2007): "Environmental testing, Part 2-2: Tests - Test B: Dry heat". [8] IEC 60068-2-14 (01-2009): "Environmental testing - Part 2-14: Tests - Test N: Change of temperature". [9] IEC 60068-2-30 (08-2005): "Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)". [10] IEC 60068-2-64 (04-2008): "Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance". [11] IEC 60068-2-27 (02-2008): "Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock". [12] IEC 60068-2-6 (12-2007): "Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)". [13] IEC 60068-2-57 (11-1999): "Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history method". [14] Void. SIST EN 300 019-2-4 V2.3.1:2013



ETSI ETSI EN 300 019-2-4 V2.3.1 (2013-08)6 [15] IEC 60068-2-18 (10-2000): "Environmental testing - Part 2-18: Tests - Test R and guidance: Water". [16] IEC 60068-2-78 (08-2001): "Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state". 2.2 Informative references The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. [i.1] ETSI EN 300 019-2-0: "Environmental Engineering (EE); Environmental conditions and environmental tests for telecommunications equipment; Part 2-0: Specification of environmental tests; Introduction". [i.2] IEC 60068-2-68 (8-1994): "Environmental testing - Part 2: Tests - Test L: Dust and sand". 3 Environmental test specifications The detailed descriptions of the environmental conditions are given in clauses 4 and 5 of EN 300 019-1-4 [1]. EN 300 019-2-0 [i.1] forms a general overview of part 2 of this multipart deliverable. The equipment under test is assumed to be in its operational state throughout the test conditions described in the present document unless otherwise stated. The required performance before, during and after the test need to be specified in the product specification. Input and load conditions of the equipment shall be chosen to obtain full utilization of the equipment under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where it shall be minimized. SIST EN 300 019-2-4 V2.3.1:2013



ETSI ETSI EN 300 019-2-4 V2.3.1 (2013-08)7 3.1 Specification T 4.1: Non-weatherprotected locations, climatic tests This specification applies to most of Europe as described in EN 300 019-1-4 [1] (see table 1). Table 1: Test specification T 4.1: Stationary use at non-weatherprotected locations - climatic tests Environmental parameter Environmental Class 4.1 Environmental test specification T 4.1: Stationary use, Non-weatherprotected locations Type Parameter Detail parameter Characteristic severity Test severity Duration Reference Method Notes Air temperature Low
(°C) -33 -33 or -45 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1 High
(°C) +40 +40 or +55 16 h IEC 60068-2-2 [7] Bb/Bd: Dry heat 2 Change
(°C)
(°C/min)
0,5 -10/+40 0,5 2 cycles t1 = 3 h IEC 60068-2-14 [8] Nb: Change of temperature 3 Humidity Relative
Low (%) 15 none
8 high (%)
(°C) 100 93 +30 10 d IEC 60068-2-78 [16] Cab: Damp heat steady state 4 condensation
(%)
(°C) yes
90-100 +30
2 cycles
IEC 60068-2-30 [9]
Db: Damp heat, cyclic Variant 1 5 Absolute Low (g/m3) 0,26 none
high (g/m3) 25
6 Air Pressure Low (kPa) 70 none
7 high (kPa) 106 none
7 Speed
(m/s) 50 none
8 Water Rain Intensity 6 mm/min 0,01 m3/min 90 kPa 3 min/m2 or 15 min IEC 60068-2-18 [15] Rb: Impacting water Method 1 9 low temperature (°C) +5 none
Other sources
splashing water
10 Icing & frosting
yes none
8 Radiation Solar
(W/m2) 1 120
11 Heat
(W/m2) negligible
SIST EN 300 019-2-4 V2.3.1:2013



ETSI ETSI EN 300 019-2-4 V2.3.1 (2013-08)8 Environmental parameter Environmental Class 4.1 Environmental test specification T 4.1: Stationary use, Non-weatherprotected locations Type Parameter Detail parameter Characteristic severity Test severity Duration Reference Method Notes Chemically active substances Sulphur SO2 (mg/m3) 0,3/1,0 none
12 H2S (mg/m3) 0,1/0,5 none
12 Chlorine salt mist sea and road salt none
12 Cl (mg/m3) 0,1/0,3 none
12 HCI (mg/m3) 0,1/0,5 none
12 Nitrogen NOx (mg/m3) 0,5/1,0 none
12 NH3 (mg/m3) 1,0/3,0 none
12 Hydrogen fluoride HF
(mg/m3) 0,01/0,03 none
12 Ozone O3
(mg/m3) 0,05/0,1 none
12 Mechanically active substances Dust sedimentation
(mg/(m2h)) 20
13 suspension (mg/m3) 5
13 Sand
(mg/m3) 300
13 Flora and fauna Micro organisms mould, fungus, etc. none
14 Rodents, insects rodents, etc. none
14 NOTE 1: none = verification is required only in special cases. NOTE 2: n = number of note, see clause 5.
SIST EN 300 019-2-4 V2.3.1:2013



ETSI ETSI EN 300 019-2-4 V2.3.1 (2013-08)9 3.2 Specification T 4.1E: Non-weatherprotected locations - extended, climatic tests This specification covers most of Europe as described in EN 300 019-1-4 [1] (see table 2). Table 2: Test specification T 4.1E: Stationary use at non-weatherprotected locations, extended - climatic tests Environmental parameter Environmental Class 4.1E Environmental test specification T 4.1E: Stationary use Non-weatherprotected locations - extended Type Parameter Detail parameter Characteristic severity Test severity Duration Reference Method Notes Air temperature Low
(°C) -45 -45 or -55 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1 High
(°C) +45 +45 or +60 16 h IEC 60068-2-2 [7] Bb/Bd: Dry heat 2 Change
(°C)
(°C/min)
0,5 -10/+45 0,5 2 cycles t1 = 3 h IEC 60068-2-14 [8] Nb: Change of temperature 3
Humidity
Relative low (%) 8 none
8 high (%)
(°C) 100 93 +30 10 d
IEC 60068-2-78 [16] Cab: Damp heat steady state 4 condensation
(%)
(°C) yes
90–100 +30 2 cycles IEC 60068-2-30 [9] Db: Damp heat cyclic Variant 1 5 Absolute low (g/m3) 0,03 none
6 high (g/m3) 30
Air Pressure low (kPa) 70 none
7 high (kPa) 106 none
7 Speed
(m/s) 50
none
8 Water Rain intensity 15 mm/min 0,01 m3/min
90 kPa 6 min/m2 or 30 min IEC 60068-2-18 [15] Rb: Impacting water, method 1 9 low temperature (°C) +5 none
Other sources
splashing water
10 Icing & frosting
yes none
8 Radiation Solar
(W/m2) 1 120
11 Heat
(W/m2) negligible
SIST EN 300 019-2-4 V2.3.1:2013



ETSI ETSI EN 300 019-2-4 V2.3.1 (2013-08)10 Environmental parameter
Environmental Class 4.1E Environmental test specification T 4.1E: Stationary use Non-weatherprotected locations – extended Type Parameter Detail parameter Characteristic severity Test severity Duration Reference Method Notes Chemically active substances Sulphur SO2 (mg/m3) 0,3/1,0 none
12 H2S (mg/m3) 0,1/0,5 none
12 Chlorine salt mist sea and road salt none
12 Cl (mg/m3) 0,1/0,3 none
12 HCl (mg/m3) 0,1/0,5 none
12 Nitrogen NOx (mg/m3) 0,5/1,0 none
12 NH3 (mg/m3) 1,0/3,0 none
12 Hydrogen fluoride HF
(mg/m3) 0,01/0,03 none
12 Ozone O3
(mg/m3) 0,05/0,1 none
12 Mechanically active substances Dust sedimentation
(mg/(m2h)) 20
13 suspension
(mg/m3) 5
13 Sand
(mg/m3) 300
13 Flora and fauna Micro organisms mould, fungus, etc. none
14 Rodents, insects rodents, etc. none
14 NOTE 1: none = verification is required only in special cases. NOTE 2: n = number of note, see clause 5.
SIST EN 300 019-2-4 V2.3.1:2013



ETSI ETSI EN 300 019-2-4 V2.3.1 (2013-08)11 3.3 Specification T 4.2L: Non-weatherprotected locations – extremely cold, climatic tests This specification covers world-wide conditions as described in EN 300 019-1-4 [1] (see table 3). Table 3: Test specification T 4.2L: Stationary use at non-weatherprotected locations, extremely cold - climatic tests Environmental parameter Environmental Class 4.2L Environmental test specification T 4.2L: Stationary use Non-weatherprotected locations – extremely cold Type Parameter Detail parameter Characteristic severity Test severity Duration Reference Method Notes Air temperature Low
(°C) -65 -65 or -75 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1 High
(°C
...

Final draft ETSI EN 300 019-2-4 V2.3.1 (2013-06)






European Standard
Environmental Engineering (EE);
Environmental conditions and environmental tests
for telecommunications equipment;
Part 2-4: Specification of environmental tests;
Stationary use at non-weatherprotected locations

---------------------- Page: 1 ----------------------
2 Final draft ETSI EN 300 019-2-4 V2.3.1 (2013-06)



Reference
REN/EE-01049
Keywords
environment, testing
ETSI
650 Route des Lucioles
F-06921 Sophia Antipolis Cedex - FRANCE

Tel.: +33 4 92 94 42 00  Fax: +33 4 93 65 47 16

Siret N° 348 623 562 00017 - NAF 742 C
Association à but non lucratif enregistrée à la
Sous-Préfecture de Grasse (06) N° 7803/88

Important notice
Individual copies of the present document can be downloaded from:
http://www.etsi.org
The present document may be made available in more than one electronic version or in print. In any case of existing or
perceived difference in contents between such versions, the reference version is the Portable Document Format (PDF).
In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive
within ETSI Secretariat.
Users of the present document should be aware that the document may be subject to revision or change of status.
Information on the current status of this and other ETSI documents is available at
http://portal.etsi.org/tb/status/status.asp
If you find errors in the present document, please send your comment to one of the following services:
http://portal.etsi.org/chaircor/ETSI_support.asp
Copyright Notification
No part may be reproduced except as authorized by written permission.
The copyright and the foregoing restriction extend to reproduction in all media.

© European Telecommunications Standards Institute 2013.
All rights reserved.

TM TM TM
DECT , PLUGTESTS , UMTS and the ETSI logo are Trade Marks of ETSI registered for the benefit of its Members.
TM
3GPP and LTE™ are Trade Marks of ETSI registered for the benefit of its Members and
of the 3GPP Organizational Partners.
GSM® and the GSM logo are Trade Marks registered and owned by the GSM Association.
ETSI

---------------------- Page: 2 ----------------------
3 Final draft ETSI EN 300 019-2-4 V2.3.1 (2013-06)
Contents
Intellectual Property Rights . 4
Foreword . 4
1 Scope . 5
2 References . 5
2.1 Normative references . 5
2.2 Informative references . 6
3 Environmental test specifications . 6
3.1 Specification T 4.1: Non-weatherprotected locations, climatic tests . 7
3.2 Specification T 4.1E: Non-weatherprotected locations - extended, climatic tests . 9
3.3 Specification T 4.2L: Non-weatherprotected locations – extremely cold, climatic tests . 11
3.4 Specification T 4.2H: Non-weatherprotected locations – extremely warm dry, climatic tests . 13
3.5 Specification T 4.1, 4.1E, 4.2L and 4.2H: Non-weatherprotected locations - mechanical tests . 15
4 Earthquake test specification . 16
4.1 Vibration response investigation . 16
4.2 Test conditioning . 16
5 Notes to tables . 18
5.1 General note . 18
5.2 Notes to tables 1 to 6 . 19
Annex A (informative): Bibliography . 21
History . 22

ETSI

---------------------- Page: 3 ----------------------
4 Final draft ETSI EN 300 019-2-4 V2.3.1 (2013-06)
Intellectual Property Rights
IPRs essential or potentially essential to the present document may have been declared to ETSI. The information
pertaining to these essential IPRs, if any, is publicly available for ETSI members and non-members, and can be found
in ETSI SR 000 314: "Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in
respect of ETSI standards", which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web
server (http://ipr.etsi.org).
Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee
can be given as to the existence of other IPRs not referenced in SR 000 314 (or the updates on the ETSI Web server)
which are, or may be, or may become, essential to the present document.
Foreword
This final draft European Standard (EN) has been produced by ETSI Technical Committee Environmental Engineering
(EE), and is now submitted for the Vote phase of the ETSI standards EN Approval Procedure.
The present document is part 2, sub-part 4 of a multi-part deliverable. Full details of the entire series can be found in
part 2, sub-part 0 [i.1].

Proposed national transposition dates
Date of latest announcement of this EN (doa): 3 months after ETSI publication
Date of latest publication of new National Standard
or endorsement of this EN (dop/e): 6 months after doa
Date of withdrawal of any conflicting National Standard (dow): 6 months after doa

ETSI

---------------------- Page: 4 ----------------------
5 Final draft ETSI EN 300 019-2-4 V2.3.1 (2013-06)
1 Scope
The present document specifies test methods and severities for verification of the required resistibility of equipment
according to the relevant environmental class.
The tests defined in the present document apply to stationary use of equipment at non-weatherprotected locations
covering the environmental conditions stated in EN 300 019-1-4 [1].
2 References
References are either specific (identified by date of publication and/or edition number or version number) or
non-specific. For specific references, only the cited version applies. For non-specific references, the latest version of the
reference document (including any amendments) applies.
Referenced documents which are not found to be publicly available in the expected location might be found at
http://docbox.etsi.org/Reference.
NOTE: While any hyperlinks included in this clause were valid at the time of publication, ETSI cannot guarantee
their long term validity.
2.1 Normative references
The following referenced documents are necessary for the application of the present document.
[1] ETSI EN 300 019-1-4: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 1-4: Classification of environmental
conditions; Stationary use at non-weatherprotected locations".
[2] IEC 60068-2-1 (03-2007): "Environmental testing, Part 2-1: Tests - Test A: Cold".
[3] Void.
[4] IEC 60721-3-4: "Classification of environmental conditions - Part 3: Classification of groups of
environmental parameters and their severities - Section 4: Stationary use at non-weatherprotected
locations".
[5] ANSI T1.0600329 (2008): "Network Equipment - Earthquake Resistance Standard".
[6] Void.
[7] IEC 60068-2-2 (07-2007): "Environmental testing, Part 2-2: Tests - Test B: Dry heat".
[8] IEC 60068-2-14 (01-2009): "Environmental testing - Part 2-14: Tests - Test N: Change of
temperature".
[9] IEC 60068-2-30 (08-2005): "Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic
(12 h + 12 h cycle)".
[10] IEC 60068-2-64 (04-2008): "Environmental testing - Part 2-64: Tests - Test Fh: Vibration,
broadband random and guidance".
[11] IEC 60068-2-27 (02-2008): "Environmental testing - Part 2-27: Tests - Test Ea and guidance:
Shock".
[12] IEC 60068-2-6 (12-2007): "Environmental testing - Part 2-6: Tests - Test Fc: Vibration
(sinusoidal)".
[13] IEC 60068-2-57 (11-1999): "Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-
history method".
[14] Void.
ETSI

---------------------- Page: 5 ----------------------
6 Final draft ETSI EN 300 019-2-4 V2.3.1 (2013-06)
[15] IEC 60068-2-18 (10-2000): "Environmental testing - Part 2-18: Tests - Test R and guidance:
Water".
[16] IEC 60068-2-78 (08-2001): "Environmental testing - Part 2-78: Tests - Test Cab: Damp heat,
steady state".
2.2 Informative references
The following referenced documents are not necessary for the application of the present document but they assist the
user with regard to a particular subject area.
[i.1] ETSI EN 300 019-2-0: "Environmental Engineering (EE); Environmental conditions and
environmental tests for telecommunications equipment; Part 2-0: Specification of environmental
tests; Introduction".
[i.2] IEC 60068-2-68 (8-1994): "Environmental testing - Part 2: Tests - Test L: Dust and sand".
3 Environmental test specifications
The detailed descriptions of the environmental conditions are given in clauses 4 and 5 of EN 300 019-1-4 [1].
EN 300 019-2-0 [i.1] forms a general overview of part 2 of this multipart deliverable.
The equipment under test is assumed to be in its operational state throughout the test conditions described in the present
document unless otherwise stated. The required performance before, during and after the test need to be specified in the
product specification. Input and load conditions of the equipment shall be chosen to obtain full utilization of the
equipment under test. The heat dissipation shall be maximized, except for the steady state, low temperature test, where
it shall be minimized.
ETSI

---------------------- Page: 6 ----------------------
7 Final draft ETSI EN 300 019-2-4 V2.3.1 (2013-06)
3.1 Specification T 4.1: Non-weatherprotected locations, climatic tests
This specification applies to most of Europe as described in EN 300 019-1-4 [1] (see table 1).
Table 1: Test specification T 4.1: Stationary use at non-weatherprotected locations - climatic tests
Environmental parameter Environmental Environmental test specification T 4.1: Stationary use,
Class 4.1 Non-weatherprotected locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
(°C) -33 -33 or -45 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1
Low
Air
High (°C) +40 +40 or +55 16 h IEC 60068-2-2 [7] Bb/Bd: Dry heat 2
temperature
(°C) -10/+40 2 cycles IEC 60068-2-14 [8] Nb: Change of 3
Change
(°C/min) 0,5 0,5 t = 3 h temperature

1
Low (%) 15 none  8
high (%) 100 93 10 d IEC 60068-2-78 [16] Cab: Damp heat 4
Relative (°C) +30 steady state

condensation yes   5
Humidity
(%) 90-100 2 cycles IEC 60068-2-30 [9] Db: Damp heat, cyclic
(°C) +30 Variant 1
3
0,26 none
Low (g/m )

Absolute
3
25   6
high (g/m )
Low (kPa) 70 none  7
Pressure
high (kPa) 106 none  7
Air
Speed (m/s) 50 none  8

3 2
Intensity 6 mm/min IEC 60068-2-18 [15] Rb: Impacting water 9
0,01 m /min 3 min/m or
Method 1
Rain
90 kPa 15 min
low temperature (°C) +5 none
Water
Other splashing water   10
sources
Icing & yes none  8
frosting
2
1 120   11
Solar
(W/m )
Radiation
2
negligible
Heat
(W/m )

ETSI

---------------------- Page: 7 ----------------------
8 Final draft ETSI EN 300 019-2-4 V2.3.1 (2013-06)
Environmental parameter Environmental Environmental test specification T 4.1: Stationary use,
Class 4.1 Non-weatherprotected locations
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
3
0,3/1,0 none  12
SO (mg/m )
2
Sulphur
3
0,1/0,5 none  12
HS (mg/m )
2
salt mist sea and road salt none  12
3
0,1/0,3 none  12
Chlorine Cl (mg/m )
Chemically
3
0,1/0,5 none  12
HCI (mg/m )
active
3
substances
0,5/1,0 none  12
NO (mg/m )
x
Nitrogen
3
1,0/3,0 none  12
NH (mg/m )
3
3 0,01/0,03 none  12
Hydrogen fluoride HF
(mg/m )
Ozone O 3
0,05/0,1 none  12
3 (mg/m )
sedimentation 20   13
Mechanically
2
Dust (mg/(m h))
active
3
5   13
suspension (mg/m )
substances
3
300   13
Sand
(mg/m )
Micro organisms mould, fungus, etc. none  14
Flora and
fauna Rodents, insects rodents, etc. none  14
NOTE 1: none = verification is required only in special cases.
NOTE 2: n = number of note, see clause 5.

ETSI

---------------------- Page: 8 ----------------------
9 Final draft ETSI EN 300 019-2-4 V2.3.1 (2013-06)
3.2 Specification T 4.1E: Non-weatherprotected locations - extended, climatic tests
This specification covers most of Europe as described in EN 300 019-1-4 [1] (see table 2).
Table 2: Test specification T 4.1E: Stationary use at non-weatherprotected locations, extended - climatic tests
Environmental parameter Environmental Environmental test specification T 4.1E: Stationary use
Class 4.1E Non-weatherprotected locations - extended
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
Low (°C) -45 -45 or -55 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1
Air High (°C) +45 +45 or +60 16 h IEC 60068-2-2 [7] Bb/Bd: Dry heat 2
temperature
(°C) -10/+45 2 cycles IEC 60068-2-14 [8] Nb: Change of temperature 3
Change
(°C/min) 0,5 0,5 t1 = 3 h
low (%) 8 none  8
high (%) 100 93 10 d IEC 60068-2-78 [16] Cab: Damp heat steady state 4
 (°C) +30
Relative
condensation yes 2 cycles IEC 60068-2-30 [9] Db: Damp heat cyclic Variant 1 5

(%) 90–100
Humidity
(°C) +30
3
0,03 none  6
low (g/m )
Absolute
3
30
high (g/m )
low (kPa) 70 none  7
Pressure
high (kPa) 106 none  7
Air
(m/s) 50 none  8
Speed

3 2
intensity 15 mm/min IEC 60068-2-18 [15] Rb: Impacting water, method 1 9
0,01 m /min 90 kPa 6 min/m or 30 min
Rain
low temperature (°C) +5 none
Water
Other sources splashing water   10
Icing & frosting yes none  8
2
1 120   11
Solar
(W/m )
Radiation
2
negligible
Heat
(W/m )

ETSI

---------------------- Page: 9 ----------------------
10 Final draft ETSI EN 300 019-2-4 V2.3.1 (2013-06)
Environmental parameter Environmental Environmental test specification T 4.1E: Stationary use
Class 4.1E Non-weatherprotected locations – extended
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
3
Chemically Sulphur 0,3/1,0 none  12
SO (mg/m )
2
active
3
0,1/0,5 none  12
HS (mg/m )
substances 2
Chlorine salt mist sea and road salt none  12
3
0,1/0,3 none  12
Cl (mg/m )
3
0,1/0,5 none  12
HCl (mg/m )
3
Nitrogen 0,5/1,0 none  12
NO (mg/m )
x
3
1,0/3,0 none  12
NH (mg/m )
3
Hydrogen fluoride HF 3 0,01/0,03 none  12
(mg/m )
Ozone O 3
0,05/0,1 none  12
3 (mg/m )
Mechanically Dust sedimentation 20   13
2
active
(mg/(m h))
substances
suspension 5   13
3
(mg/m )
3
Sand 300   13
(mg/m )
Flora and Micro organisms mould, fungus, etc. none  14
fauna
Rodents, insects rodents, etc. none  14
NOTE 1: none = verification is required only in special cases.
NOTE 2: n = number of note, see clause 5.

ETSI

---------------------- Page: 10 ----------------------
11 Final draft ETSI EN 300 019-2-4 V2.3.1 (2013-06)
3.3 Specification T 4.2L: Non-weatherprotected locations – extremely cold, climatic tests
This specification covers world-wide conditions as described in EN 300 019-1-4 [1] (see table 3).
Table 3: Test specification T 4.2L: Stationary use at non-weatherprotected locations, extremely cold - climatic tests
Environmental parameter Environmental Environmental test specification T 4.2L: Stationary use
Class 4.2L Non-weatherprotected locations – extremely cold
Type Parameter Detail parameter Characteristic Test severity Duration Reference Method Notes
severity
Low (°C) -65 -65 or -75 16 h IEC 60068-2-1 [2] Ab/Ad: Cold 1
Air High (°C) +35 +35 or +50 16 h IEC 60068-2-2 [7] Bb/Bd: Dry heat 2
temperature
(°C) -10/+45 2 cycles IEC 60068-2-14 [8] Nb: Change of temperature 3
Change
(°C/min) 0,5 0,5 t1 = 3 h
low (%) 20 none  8
high (%) 100 93 10 d IEC 60068-2-78 [16] Cab: Damp heat steady state 4
 (°C) +30
Relative
condensation yes 2 cycles IEC 60068-2-30 [9] Db: Damp heat cyclic Variant 1 5

(%) 90 –100
Humidity
(°C) +30
3