SIST EN ISO 11073-10421:2013
(Main)Health informatics - Personal health device communication - Part 10421: Device specialization - Peak expiratory flow monitor (peak flow) (ISO 11073-10421:2012)
Health informatics - Personal health device communication - Part 10421: Device specialization - Peak expiratory flow monitor (peak flow) (ISO 11073-10421:2012)
The scope of this standard is to establish a normative definition of communication between personal telehealth peak flow monitoring devices (agents) and managers (e.g., cell phones, personal computers, personal health appliances, and set top boxes) in a manner that enables plug-and-play interoperability. It leverages work done in other ISO/IEEE 11073 standards including existing terminology, information profiles, application profile standards, and transport standards. It specifies the use of specific term codes, formats, and behaviors in telehealth environments restricting optionality in base frameworks in favor of interoperability. This standard defines a common core of functionality of a peak-flow monitoring device. The use case is restricted to personal respiratory monitoring and therefore does not include hospital-based spirometry. Continuous and high-acuity monitoring (e.g., for emergency response) are outside the scope of the use case. In the context of personal health devices, a peak flow meter is a device used to measure the respiratory function of those managing respiratory conditions such as asthma and chronic obstructive pulmonary disease. The ability to identify declining respiratory status prior to the need for acute intervention improves the quality of life for the individual while reducing the overall costs of care. Respiratory status data are collected by a personal respiratory monitoring device and forwarded to a central data repository for review and action by a health care provider. The data are episodic in nature and are forwarded at designated intervals or when the person is symptomatic.
Medizinische Informatik - Kommunikation von Geräten für die persönliche Gesundheit - Teil 10421: Gerätespezifikation - Monitor für den maximalen exspiratorischen Atemfluss (peak flow) (ISO/IEEE 11073-10421:2012)
Informatique de santé - Communication entre dispositifs de santé personnels - Partie 10421: Spécialisation de dispositif - Moniteur du flux rexpiratoire de crête (flux de crête) (ISO 11073-10421:2012)
Dans le contexte de la famille de Normes ISO/IEEE 11073 relatives à la communication de dispositifs, l'ISO/IEEE 11073-10421:2012 établit une définition normative de la communication entre les dispositifs personnels d'analyse de composition corporelle et des gestionnaires (par exemple, des téléphones cellulaires, des ordinateurs personnels, des équipements personnels de santé, des boîtiers décodeurs) d'une manière qui permet une interopérabilité du type prêt à l'emploi. Elle s'appuie sur un travail effectué dans d'autres normes ISO/IEEE 11073, y compris la terminologie, les profils d'informations, les normes de profils d'applications et les normes de transports existants. Elle spécifie l'utilisation de codes, de formats et de comportements en termes spécifiques dans les environnements de télésanté, en limitant les choix à des cadres de travail de base en faveur de l'interopérabilité. Elle définit un noyau commun de fonctionnalités d'un dispositif de surveillance de débit de pointe.
Zdravstvena informatika - Komunikacija osebnih medicinskih naprav - 10421. del: Specialne naprave - Merilnik vršne vrednosti izdihanega zraka (ISO 11073-10421:2012)
Področje uporabe tega standarda določa normativno opredelitev komunikacije med osebnimi telemedicinskimi napravami za merjenje vršne vrednosti izdihanega zraka in upravljalnimi napravami (npr. mobilnimi telefoni, osebnimi računalniki, osebnimi medicinskimi napravami in digitalnimi sprejemniki) na način, ki omogoča interoperabilnost Plug and Play. Standard temelji na delu, doseženem v drugih standardih ISO/IEEE 11073, vključno z obstoječo terminologijo, informacijskimi profili, standardi za profile aplikacije in standardi za prevoz. Določa uporabo posebnih kod izrazov, formatov in vedenj v telemedicinskih okoljih ter v korist interoperabilnosti omejuje opcionalnost osnovnih okvirov. Ta standard določa skupno jedro funkcionalnosti za napravo za merjenje vršne vrednosti. Primer uporabe je omejen na osebno merjenje izdihanega zraka in zato ne vključuje spirometrije, ki se izvaja v bolnišnici. Trajno merjenje in merjenje v primeru visoke akutnosti (npr. v okviru odziva na izredne razmere) ne spadata na področje uporabe tega primera. Merilnik vršne vrednosti izdihanega zraka se v okviru osebnih medicinskih naprav uporablja za merjenje dihalne funkcije pri ljudeh z boleznimi dihal, kot sta astma in kronična obstruktivna pljučna bolezen. Sposobnost opredelitve slabitve dihanja pred potrebo po akutnemu posredovanju izboljša kakovost življenja posameznika ter niža skupne stroške oskrbe. Osebna naprava za merjenje izdihanega zraka zbira podatke o stanju dihanja in jih posreduje v osrednjo zbirko podatkov, v okviru katere te podatke pregleda izvajalec zdravstvenih storitev in ukrepa v skladu z njimi. Podatki so po naravi občasni in se posredujejo v določenih intervalih ali kadar oseba kaže znake slabitve dihanja.
General Information
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN ISO 11073-10421:2013
01-januar-2013
Zdravstvena informatika - Komunikacija osebnih medicinskih naprav - 10421. del:
Specialne naprave - Merilnik vršne vrednosti izdihanega zraka (ISO 11073-
10421:2012)
Health informatics - Personal health device communication - Part 10421: Device
specialization - Peak expiratory flow monitor (peak flow) (ISO 11073-10421:2012)
Informatique de santé - Communication entre dispositifs de santé personnels - Partie
10421: Spécialisation de dispositif - Moniteur du flux rexpiratoire de crête (flux de crête)
(ISO 11073-10421:2012)
Ta slovenski standard je istoveten z: EN ISO 11073-10421:2012
ICS:
11.040.55 'LDJQRVWLþQDRSUHPD Diagnostic equipment
35.240.80 Uporabniške rešitve IT v IT applications in health care
zdravstveni tehniki technology
SIST EN ISO 11073-10421:2013 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST EN ISO 11073-10421:2013
---------------------- Page: 2 ----------------------
SIST EN ISO 11073-10421:2013
EUROPEAN STANDARD
EN ISO 11073-10421
NORME EUROPÉENNE
EUROPÄISCHE NORM
November 2012
ICS 35.240.80
English Version
Health informatics - Personal health device communication -
Part 10421: Device specialization - Peak expiratory flow monitor
(peak flow) (ISO 11073-10421:2012)
Informatique de santé - Communication entre dispositifs de
santé personnels - Partie 10421: Spécialisation des
dispositifs - Moniteur de surveillance du débit expiratoire de
pointe (débit de pointe) (ISO 11073-10421:2012)
This European Standard was approved by CEN on 20 October 2012.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national
standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United
Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2012 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 11073-10421:2012: E
worldwide for CEN national Members.
---------------------- Page: 3 ----------------------
SIST EN ISO 11073-10421:2013
EN ISO 11073-10421:2012 (E)
Contents Page
Foreword .3
2
---------------------- Page: 4 ----------------------
SIST EN ISO 11073-10421:2013
EN ISO 11073-10421:2012 (E)
Foreword
This document (EN ISO 11073-10421:2012) has been prepared by Technical Committee ISO/TC 215 "Health
informatics" in collaboration with Technical Committee CEN/TC 251 “Health informatics” the secretariat of
which is held by NEN.
This European Standard shall be given the status of a national standard, either by publication of an identical
text or by endorsement, at the latest by May 2013, and conflicting national standards shall be withdrawn at the
latest by May 2013.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent rights.
According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following
countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech
Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece,
Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
Endorsement notice
The text of ISO 11073-10421:2012 has been approved by CEN as a EN ISO 11073-10421:2012 without any
modification.
3
---------------------- Page: 5 ----------------------
SIST EN ISO 11073-10421:2013
---------------------- Page: 6 ----------------------
SIST EN ISO 11073-10421:2013
INTERNATIONAL ISO/IEEE
STANDARD 11073-10421
First edition
2012-11-01
Health informatics — Personal health
device communication —
Part 10421:
Device specialization — Peak expiratory
flow monitor (peak flow)
Informatique de santé — Communication entre dispositifs de santé
personnels —
Partie 10421: Spécialisation de dispositif — Moniteur du flux rexpiratoire
de crête (flux de crête)
Reference number
ISO/IEEE 11073-10421:2012(E)
©
ISO 2012
©
IEEE 2012
---------------------- Page: 7 ----------------------
SIST EN ISO 11073-10421:2013
ISO/IEEE 11073-10421:2012(E)
COPYRIGHT PROTECTED DOCUMENT
© ISO 2012
© IEEE 2012
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO or IEEE at the respective
address below.
ISO copyright office Institute of Electrical and Electronics Engineers, Inc.
Case postale 56 CH-1211 Geneva 20 3 Park Avenue, New York NY 10016-5997, USA
Tel. + 41 22 749 01 11 E-mail stds.ipr@ieee.org
Fax + 41 22 749 09 47 Web www.ieee.org
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
© ISO 2012 – All rights reserved
ii © IEEE 2012 – All rights reserved
---------------------- Page: 8 ----------------------
SIST EN ISO 11073-10421:2013
ISO/IEEE 11073-10421:2012(E)
Contents
1. Overview . 1
1.1 Scope . 1
1.2 Purpose . 2
1.3 Context . 2
2. Normative references . 2
3. Definitions, acronyms, and abbreviations . 2
3.1 Definitions . 3
3.2 Acronyms and abbreviations . 3
4. Introduction to ISO/IEEE 11073 personal health devices . 4
4.1 General . 4
4.2 Introduction to ISO/IEEE 11073-20601 modeling constructs . 4
5. Peak expiratory flow monitor device concepts and modalities. 5
5.1 General . 5
5.2 PEF . 5
6. Peak expiratory flow monitor domain information model . 7
6.1 Overview . 7
6.2 Class extensions . 7
6.3 Object instance diagram . 7
6.4 Types of configuration . 9
6.5 Medical device system object . 9
6.6 Numeric objects . 13
6.7 Real-time sample array objects . 20
6.8 Enumeration objects . 20
6.9 PM-store objects . 22
6.10 Scanner objects . 22
6.11 Class extension objects . 22
6.12 Peak expiratory flow monitor information model extensibility rules . 22
7. Peak expiratory flow monitor service model . 22
7.1 General . 22
7.2 Object access services. 22
7.3 Object access event report services . 23
© ISO 2012 – All rights reserved
© IEEE 2012 – All rights reserved iii
---------------------- Page: 9 ----------------------
SIST EN ISO 11073-10421:2013
ISO/IEEE 11073-10421:2012(E)
8. Peak expiratory flow monitor communication model . 24
8.1 Overview . 24
8.2 Communications characteristics . 24
8.3 Association procedure . 24
8.4 Configuring procedure . 26
8.5 Operating procedure . 28
8.6 Time synchronization . 29
9. Test associations . 29
9.1 Behavior with standard configuration . 29
9.2 Behavior with extended configurations . 30
10. Conformance . 30
10.1 Applicability . 30
10.2 Conformance specification . 30
10.3 Levels of conformance . 30
10.4 Implementation conformance statements . 31
Annex A (informative) Bibliography . 36
Annex B (normative) Any additional ASN.1 definitions . 37
Annex C (normative) Allocation of identifiers . 38
Annex D (informative) Message sequence examples . 39
Annex E (informative) Protocol data unit examples . 41
Annex F (informative) IEEE list of participants . 52
© ISO 2012 – All rights reserved
iv © IEEE 2012 – All rights reserved
---------------------- Page: 10 ----------------------
SIST EN ISO 11073-10421:2013
ISO/IEEE 11073-10421:2012(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
IEEE Standards documents are developed within the IEEE Societies and the Standards Coordinating
Committees of the IEEE Standards Association (IEEE-SA) Standards Board. The IEEE develops its standards
through a consensus development process, approved by the American National Standards Institute, which
brings together volunteers representing varied viewpoints and interests to achieve the final product. Volunteers
are not necessarily members of the Institute and serve without compensation. While the IEEE administers the
process and establishes rules to promote fairness in the consensus development process, the IEEE does not
independently evaluate, test, or verify the accuracy of any of the information contained in its standards.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is called to the possibility that implementation of this standard may require the use of subject matter
covered by patent rights. By publication of this standard, no position is taken with respect to the existence or
validity of any patent rights in connection therewith. ISO/IEEE is not responsible for identifying essential
patents or patent claims for which a license may be required, for conducting inquiries into the legal validity or
scope of patents or patent claims or determining whether any licensing terms or conditions provided in
connection with submission of a Letter of Assurance or a Patent Statement and Licensing Declaration Form, if
any, or in any licensing agreements are reasonable or non-discriminatory. Users of this standard are expressly
advised that determination of the validity of any patent rights, and the risk of infringement of such rights, is
entirely their own responsibility. Further information may be obtained from ISO or the IEEE Standards
Association.
ISO/IEEE 11073-10421 was prepared by the IEEE 11073 Standards Comittee of the IEEE Engineering in
Medicine and Biology Society (as IEEE Std 11073-10421-2010). It was adopted by Technical Committee
ISO/TC 215, Health informatics, in parallel with its approval by the ISO member bodies, under the “fast-track
procedure” defined in the Partner Standards Development Organization cooperation agreement between ISO
and IEEE. IEEE is responsible for the maintenance of this document with participation and input from ISO
member bodies.
ISO/IEEE 11073 consists of the following parts, under the general title Health informatics — Personal health
device communication (text in parentheses gives a variant of subtitle):
Part 10101: (Point-of-care medical device communication) Nomenclature
Part 10201: (Point-of-care medical device communication) Domain information model
Part 10404: Device specialization — Pulse oximeter
Part 10407: Device specialization — Blood pressure monitor
Part 10408: Device specialization — Thermometer
Part 10415: Device specialization — Weighing scale
© ISO 2012 – All rights reserved
© IEEE 2012 – All rights reserved v
---------------------- Page: 11 ----------------------
SIST EN ISO 11073-10421:2013
ISO/IEEE 11073-10421:2012(E)
Part 10417: Device specialization — Glucose meter
Part 10420: Device specialization — Body composition analyzer
Part 10421: Device specialization — Peak expiratory flow monitor (peak flow)
Part 10471: Device specialization — Independant living activity hub
Part 10472: Device specialization — Medication monitor
Part 20101: (Point-of-care medical device communication) Application profiles — Base standard
Part 20601: Application profile — Optimized exchange protocol
Part 30200: (Point-of-care medical device communication) Transport profile — Cable connected
Part 30300: (Point-of-care medical device communication) Transport profile — Infrared wireless
Part 30400: (Point-of-care medical device communication) Interface profile — Cabled Ethernet
Part 90101: (Point-of-care medical device communication) Analytical instruments — Point-of-care test
Part 91064: (Standard communication protocol) Computer-assisted electrocardiography
Part 92001: (Medical waveform format) — Encoding rules
© ISO 2012 – All rights reserved
vi © IEEE 2012 – All rights reserved
---------------------- Page: 12 ----------------------
SIST EN ISO 11073-10421:2013
ISO/IEEE 11073-10421:2012(E)
Introduction
This introduction is not part of IEEE Std 11073-10421-2010, Health informatics—Personal health device
communication—Part 10421: Device specialization—Peak expiratory flow monitor (peak flow).
ISO/IEEE 11073 standards enable communication between medical devices and external computer
a
systems. This document uses the optimized framework created in IEEE Std 11073-20601-2008 and
describes a specific, interoperable communication approach for weighing scales. These standards align
with, and draw upon, the existing clinically focused standards to provide support for communication of data
from clinical or personal health devices
a
For information on references, see Clause 2.
© ISO 2012 – All rights reserved
© IEEE 2012 – All rights reserved vii
---------------------- Page: 13 ----------------------
SIST EN ISO 11073-10421:2013
---------------------- Page: 14 ----------------------
SIST EN ISO 11073-10421:2013
ISO/ISO/IEEE IEEE 111073-10421:2012(E)1073-10421:2012(E)
Health informatics — Personal health device
communication —
Part 10421:
Device specialization — Peak expiratory flow monitor
(peak flow)
IMPORTANT NOTICE: This standard is not intended to ensure safety, security, health, or
environmental protection. Implementers of the standard are responsible for determining appropriate
safety, security, environmental, and health practices or regulatory requirements.
This IEEE document is made available for use subject to important notices and legal disclaimers. These
notices and disclaimers appear in all publications containing this document and may be found under the
heading “Important Notice” or “Important Notices and Disclaimers Concerning IEEE Documents.”
They can also be obtained on request from IEEE or viewed at http://standards.ieee.org/IPR/disclaimers.html.
1 Overview
1.1 Scope
The scope of this standard is to establish a normative definition of communication between personal
telehealth peak flow monitoring devices (agents) and managers (e.g., cell phones, personal computers,
personal health appliances, and set top boxes) in a manner that enables plug-and-play interoperability. It
leverages work done in other ISO/IEEE 11073 standards including existing terminology, information
profiles, application profile standards, and transport standards. It specifies the use of specific term codes,
formats, and behaviors in telehealth environments restricting optionality in base frameworks in favor of
interoperability. This standard defines a common core of functionality of a peak-flow monitoring device.
The use case is restricted to personal respiratory monitoring and therefore does not include hospital-based
spirometry. Continuous and high-acuity monitoring (e.g., for emergency response) are outside the scope of
the use case.
In the context of personal health devices, a peak flow meter is a device used to measure the respiratory
function of those managing respiratory conditions such as asthma and chronic obstructive pulmonary
disease. The ability to identify declining respiratory status prior to the need for acute intervention improves
the quality of life for the individual while reducing the overall costs of care. Respiratory status data are
collected by a personal respiratory monitoring device and forwarded to a central data repository for review
and action by a health care provider. The data are episodic in nature and are forwarded at designated
intervals or when the person is symptomatic.
© ISO 2012 – All rights reserved
© IEEE 2012 – All rights reserved 1
---------------------- Page: 15 ----------------------
SIST EN ISO 11073-10421:2013
ISO/IEEE 11073-10421:2012(E)
This standard provides the data modeling and its transport shim layer according to IEEE Std 11073-
TM
20601 -2008 and does not specify the measurement method.
1.2 Purpose
This standard addresses a need for an openly defined, independent standard for controlling information
exchange to and from personal health devices (agents) and managers (e.g. cell phones, personal computers,
personal health appliances, set top boxes). Interoperability is key to growing the potential market for these
devices and enabling people to be better informed participants in the management of their health.
1.3 Context
See IEEE Std 11073-20601-2008 for an overview of the environment within which this standard is written.
This standard defines the device specialization for the peak expiratory flow monitor, being a specific agent
type, and it provides a description of the device concepts, its capabilities, and its implementation according
to this standard.
This standard is based on IEEE Std 11073-20601-2008, which in turn draws information from both
1
ISO/IEEE Std 11073-10201:2004 [B2] and ISO/IEEE Std 11073-20101:2004 [B3]. The medical device
encoding rules (MDERs) used within this standard are fully described in IEEE Std 11073-20601-2008.
This standard reproduces relevant portions of the nomenclature found in ISO/IEEE 11073-10101:2004 [B1]
and adds new nomenclature codes for the purposes of this standard. Between this standard and
IEEE Std 11073-20601-2008 all required nomenclature codes for implementation are documented.
NOTE—In this standard, ISO/IEEE P11073-104zz is used to refer to the collection of device specialization
2
standards that utilize IEEE Std 11073-20601-2008, where zz can be any number from 01 to 99, inclusive.
2 Normative references
The following referenced documents are indispensable for the application of this document (i.e., they must
be understood and used, so that each referenced document is cited in text and its relationship to this
document is explained). For dated references, only the edition cited applies. For undated references, the
latest edition of the referenced document (including any amendments or corrigenda) applies.
TM
IEEE Std 11073-20601 -2008, Health informatics—Personal health device communication—Application
3,4
profile—Optimized Exchange Protocol.
See Annex A for all informative material referenced by this standard.
NOTE—IEEE Std 11073-20601-2008 is referenced throughout this standard as IEEE Std 11073-20601.
1
The numbers in brackets correspond to those of the bibliography in Annex A.
2
Notes in text, tables, and figures are given for information only and do not contain requirements needed to implement the standard.
3
The IEEE standards or products referred to in this clause are trademarks of the Institute of Electrical and Electronics Engineers, Inc.
4
IEEE publications are available from the Institute of Electrical and Electronics Engineers, 445 Hoes Lane, Piscataway, NJ 08854,
USA (http://standards.ieee.org/).
© ISO 2012 – All rights reserved
© IEEE 2012 – All rights reserved
2
---------------------- Page: 16 ----------------------
SIST EN ISO 11073-10421:2013
ISO/IEEE 11073-10421:2012(E)
3 Definitions, acronyms, and abbreviations
3.1 Definitions
For the purposes of this document, the following terms and definitions apply. The IEEE Standards
5
Dictionary: Glossary of Terms & Definitions should be referenced for terms not defined in this clause.
3.1.1 agent: A node that collects and transmits personal health data to an associated manager.
3.1.2 class: In object-oriented modeling, a class describes the attributes, methods, and events that objects
instantiated from the class utilize.
3.1.3 compute engine: See: manager.
3.1.4 device: A term used to refer to a physical apparatus implementing either an agent or a manager role.
3.1.5 forced expiratory volume: The expiratory volume of a subject under forced conditions at time t in
seconds, measured from time zero.
3.1.6 handle: An unsigned 16-bit number that is locally unique and identifies one of the object instances
within an agent.
3.1.7 manager: A node receiving data from one or more agent systems. Some examples of managers include
a cellular phone, health appliance, set top box, or a computer system.
3.1.8 obj-handle: See: handle.
3.1.9 object: In object-oriented modeling, a particular instantiation of a class. The instantiation realizes
attributes, methods, and events from the class.
3.1.10 peak expiratory flow: maximum flow measured at the mouth during an expiration delivered with
maximal force starting immediately after achieving maximum lung inflation.
3.1.11 peak expiratory flow monitor: A medical device used to measure the respiratory function of those
managing respiratory conditions such as asthma.
3.1.12 personal best: This value is determined by a healthcare professional or based on predicted average peak
flow and is typically the highest peak expiratory flow (PEF) reading an individual can obtain while in peak
condition.
3.1.13 personal health device: A device used in personal health applications.
3.1.14 personal telehealth device: See: personal health device.
3.1.15 predicted average peak flow: The value of peak expiratory flow that is calculated based on the user’s
age, height, and sex to serve as a benchmark for the user’s measurements.
3.1.16 time zero: In the context of this document, time zero is the instant at which a user starts blowing into the
peak-flow monitor to record a measurement.
3.2 Acronyms and abbreviations
APDU application protocol data unit
ASN.1 Abstract Syntax Notation One
DIM domain information model
EUI-64 extended unique identifier (64 bits)
FEV forced expiratory volume
5
The IEEE Standards Dictionary: Glossary of Terms & Definitions is available at http://shop.ieee.org/.
© ISO 2012 – All rights reserved
© IEEE 2012 – All rights reserved
3
---------------------- Page: 17 ----------------------
SIST EN ISO 11073-10421:2013
ISO/IEEE 11073-10421:2012(E)
FEV1 forced expiratory volume in 1 s
FEV6 forced expiratory volume in 6 s
ICS implementation conformance statements
MDC medical device communication
MDER
...
Questions, Comments and Discussion