Dentistry - Compatibility testing - Part 2: Ceramic-ceramic systems (ISO 9693-2:2016)

This International Standard specifies test methods to assess the compatibility of metallic and ceramic materials used for dental restorations by testing composite structures.
The requirements of this International Standard apply when two different ceramic components are used in combination, and compliance may not be claimed for either ceramic alone.

Zahnheilkunde - Verbundprüfung - Teil 2: Keramik-Keramiksysteme (ISO 9693-2:2016)

Dieser Teil von ISO 9693 legt Anforderungen und Prüfverfahren fest für die Beurteilung der Kompatibilität von Keramik-Keramikwerkstoffen, die zur Herstellung von Restaurationen in der Zahnheilkunde verwendet werden, indem die Verbundstrukturen geprüft werden.
Die Anforderungen in diesem Teil von ISO 9693 gelten, wenn verschiedene Keramikkomponenten in einer Kombination verwendet werden. Die Erfüllung der Anforderungen darf nicht für eine Keramik allein beansprucht werden.
Für Anforderungen an keramische Werkstoffe siehe ISO 6872.

Médecine bucco-dentaire - Essais de compatibilité - Partie 2: Systèmes céramiques-céramiques (ISO 9693-2:2016)

ISO 9693:2016 spécifie des exigences et des méthodes d'essai qui permettent d'évaluer, au moyen d'essais sur des structures composites, la compatibilité des matériaux constitutifs des systèmes céramo-céramiques utilisés pour des restaurations dentaires.
Les exigences spécifiées dans la présente partie de l'ISO 9693 s'appliquent lorsque différents constituants céramiques sont combinés. La conformité ne peut pas être déclarée pour tout constituant céramique utilisé seul.
Pour obtenir les exigences relatives aux matériaux céramiques, voir l'ISO 6872.

Zobozdravstvo - Preskušanje združljivosti - 2. del: Keramično-keramični sistemi (ISO 9693-2:2016)

Ta mednarodni standard določa preskusne metode za oceno združljivosti kovinskih in keramičnih materialov, ki se uporabljajo za popravila zob, s preskušanjem njihove kompozitne strukture.
Zahteve tega mednarodnega standarda se uporabljajo, ko se uporablja kombinacija dveh različnih keramičnih sestavnih delov, pri čemer ni mogoče zagotoviti skladnosti za vsak keramični del posebej.

General Information

Status
Withdrawn
Public Enquiry End Date
29-Jul-2014
Publication Date
20-Apr-2016
Withdrawal Date
10-Dec-2019
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
11-Dec-2019
Due Date
03-Jan-2020
Completion Date
11-Dec-2019

Relations

Buy Standard

Standard
EN ISO 9693-2:2016
English language
17 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
SIST EN ISO 9693-2:2016
01-maj-2016
1DGRPHãþD
SIST EN ISO 9693:2001
=RER]GUDYVWYR3UHVNXãDQMH]GUXåOMLYRVWLGHO.HUDPLþQRNHUDPLþQLVLVWHPL
,62
Dentistry - Compatibility testing - Part 2: Ceramic-ceramic systems (ISO 9693-2:2016)
Zahnheilkunde - Verbundprüfung - Teil 2: Keramik-Keramiksysteme (ISO 9693-2:2016)
Médecine bucco-dentaire - Essais de compatibilité - Partie 2: Systèmes céramiques-
céramiques (ISO 9693-2:2016)
Ta slovenski standard je istoveten z: EN ISO 9693-2:2016
ICS:
11.060.10 =RERWHKQLþQLPDWHULDOL Dental materials
SIST EN ISO 9693-2:2016 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------

SIST EN ISO 9693-2:2016

---------------------- Page: 2 ----------------------

SIST EN ISO 9693-2:2016


EN ISO 9693-2
EUROPEAN STANDARD

NORME EUROPÉENNE

March 2016
EUROPÄISCHE NORM
ICS 11.060.10 Supersedes EN ISO 9693:2000
English Version

Dentistry - Compatibility testing - Part 2: Ceramic-ceramic
systems (ISO 9693-2:2016)
Médecine bucco-dentaire - Essais de compatibilité - Zahnheilkunde - Verbundprüfung - Teil 2: Keramik-
Partie 2: Systèmes céramo-céramiques (ISO 9693- Keramiksysteme (ISO 9693-2:2016)
2:2016)
This European Standard was approved by CEN on 13 December 2015.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.

This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,
Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.





EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2016 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 9693-2:2016 E
worldwide for CEN national Members.

---------------------- Page: 3 ----------------------

SIST EN ISO 9693-2:2016
EN ISO 9693-2:2016 (E)
Contents Page
European foreword . 3
2

---------------------- Page: 4 ----------------------

SIST EN ISO 9693-2:2016
EN ISO 9693-2:2016 (E)
European foreword
This document (EN ISO 9693-2:2016) has been prepared by Technical Committee
ISO/TC 106 “Dentistry” in collaboration with Technical Committee CEN/TC 55 “Dentistry” the
secretariat of which is held by DIN.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by September 2016, and conflicting national standards
shall be withdrawn at the latest by September 2016.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN [and/or CENELEC] shall not be held responsible for identifying any or all such patent
rights.
This document supersedes EN ISO 9693:2000.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta,
Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
Endorsement notice
The text of ISO 9693-2:2016 has been approved by CEN as EN ISO 9693-2:2016 without any
modification.

3

---------------------- Page: 5 ----------------------

SIST EN ISO 9693-2:2016

---------------------- Page: 6 ----------------------

SIST EN ISO 9693-2:2016
INTERNATIONAL ISO
STANDARD 9693-2
First edition
2016-02-15
Dentistry — Compatibility testing —
Part 2:
Ceramic-ceramic systems
Médecine bucco-dentaire — Essais de compatibilité —
Partie 2: Systèmes céramo-céramiques
Reference number
ISO 9693-2:2016(E)
©
ISO 2016

---------------------- Page: 7 ----------------------

SIST EN ISO 9693-2:2016
ISO 9693-2:2016(E)

COPYRIGHT PROTECTED DOCUMENT
© ISO 2016, Published in Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form
or by any means, electronic or mechanical, including photocopying, or posting on the internet or an intranet, without prior
written permission. Permission can be requested from either ISO at the address below or ISO’s member body in the country of
the requester.
ISO copyright office
Ch. de Blandonnet 8 • CP 401
CH-1214 Vernier, Geneva, Switzerland
Tel. +41 22 749 01 11
Fax +41 22 749 09 47
copyright@iso.org
www.iso.org
ii © ISO 2016 – All rights reserved

---------------------- Page: 8 ----------------------

SIST EN ISO 9693-2:2016
ISO 9693-2:2016(E)

Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Requirements . 1
4.1 Biocompatibility . 1
4.2 Physical properties . 2
4.2.1 General. 2
4.2.2 Thermal expansion . 2
4.2.3 De-bonding/crack-initiation test (zirconia-porcelain only) . 2
4.2.4 Thermal shock resistance . 2
5 Sampling . 2
5.1 Substructure dental ceramic . 2
5.2 Dental porcelain . 2
6 Test methods . 2
6.1 Linear thermal expansion . 2
6.2 Glass transition temperature . 2
6.3 De-bonding/crack-initiation test (zirconia-porcelain only) . 3
6.3.1 Preparation of test specimens . 3
6.3.2 Determination of fracture force . 3
6.3.3 Test report . 5
6.4 Thermal shock testing . 5
6.4.1 General. 5
6.4.2 Thermocycling test with fixed temperature interval. 5
6.4.3 Thermocycling test with increasing temperature interval . 6
7 Test report . 7
Bibliography . 9
© ISO 2016 – All rights reserved iii

---------------------- Page: 9 ----------------------

SIST EN ISO 9693-2:2016
ISO 9693-2:2016(E)

Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out
through ISO technical committees. Each member body interested in a subject for which a technical
committee has been established has the right to be represented on that committee. International
organizations, governmental and non-governmental, in liaison with ISO, also take part in the work.
ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of
electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are
described in the ISO/IEC Directives, Part 1. In particular the different approval criteria needed for the
different types of ISO documents should be noted. This document was drafted in accordance with the
editorial rules of the ISO/IEC Directives, Part 2 (see www.iso.org/directives).
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. ISO shall not be held responsible for identifying any or all such patent rights. Details of
any patent rights identified during the development of the document will be in the Introduction and/or
on the ISO list of patent declarations received (see www.iso.org/patents).
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation on the meaning of ISO specific terms and expressions related to conformity
assessment, as well as information about ISO’s adherence to the WTO principles in the Technical
Barriers to Trade (TBT) see the following URL: Foreword - Supplementary information
The committee responsible for this document is ISO/TC 106, Dentistry, Subcommittee SC 2,
Prosthodontic materials.
This first edition, together with ISO 9693-1, cancels and replaces ISO 9693:1999.
This part of ISO 9693 replaces the bi-material portions of ISO 9693:1999 to focus only on the
compatibility of veneering porcelains fired onto substrate ceramics. Tests of all ceramic materials for
either metal or ceramic substructures are now contained in a global ceramics standard ISO 6872. Some
elements of ISO 9693:1999 remain for all materials (e.g. measurement of thermal expansion coefficients)
and one remains only for porcelain fired to zirconia (Schwickerath bond characterization test). New
requirements have been added for porcelain-ceramic systems, including thermal shock testing for
ceramic-ceramic compatibility (allowing many protocols that are in widespread use within industry).
ISO 9693 consists of the following parts, under the general title Dentistry — Compatibility testing:
— Part 1: Metal-ceramic systems
— Part 2: Ceramic-ceramic systems
iv © ISO 2016 – All rights reserved

---------------------- Page: 10 ----------------------

SIST EN ISO 9693-2:2016
ISO 9693-2:2016(E)

Introduction
Dental porcelains and substructure ceramics are suitable for use in fabrication of all-ceramic dental
restorations. Their compatibility under mec
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.