MT 20 - TC 62/SC 62D/MT 20
TC 62/SC 62D/MT 20
General Information
IEC TR 62653:2020 is available as IEC TR 62653:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC TR 62653:2020 describes the technical recommendations for use of medical equipment in chronic Haemodialysis, Haemofiltration and Haemodiafiltration. These principles are important to be complied with to ensure safe, permissible and appropriate application. The term Haemodialysis is used in this document as synonym for all therapy modalities.
The scope can be applicable to the use of the medical equipment in home, acute and pediatrics environment. The scope may also be applicable to Sorbent Dialysis Systems.
The physician is responsible for the treatment prescription. However, the Organization administering the treatment is responsible for all resources, structures and processes used in connection with the treatment. These responsibilities will not be described here. The requirements of IEC 60601-2-16 ensure that medical electrical equipment used for extracorporeal renal replacement therapy operates with a high level of safety. Despite that high level of safety, however, some residual risk remains, related to medical-biological, physical-chemical and technical Hazards. The Organization administering the treatment is responsible for managing the residual risk. This document is not intended to be used as the basis of regulatory inspection or certification assessment activities. IEC TR 62653:2020 cancels and replaces the first edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) update the relevant references to the new numbering scheme of the ISO 23500 family;
b) alignment with IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012, IEC 62353:2014 and 60601-2-16:2018;
c) technical additions in several sections.
- Technical report36 pagesEnglish languagesale 15% off
IEC 60601-2-16:2018 is also available as IEC 60601-2-16:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60601-2-16:2018 applies to the basic safety and essential performance of haemodialysis, haemodiafiltration and haemofiltration equipment. IEC 60601-2-16:2018 does not take into consideration the dialysis fluid control system of Haemodialysis equipment using regeneration of dialysis fluid and central delivery systems. It does however take into consideration the specific safety requirements of such haemodialysis equipment concerning electrical safety and patient safety. IEC 60601-2-16:2018 specifies the minimum safety requirements for haemodialysis equipment. These devices are intended for use either by medical staff or for use by the patient or other trained personnel under the supervision of medical expertise. IEC 60601-2-16:2018 includes all electromedical equipment that is intended to deliver a haemodialysis, haemodiafiltration and haemofiltration treatment to a patient suffering from kidney failure. This fifth edition cancels and replaces the fourth edition of IEC 60601-2-16, published in 2012. This edition includes the following significant technical changes with respect to the previous edition:
a) update of references to IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012, of references and requirements to IEC 60601-1-2:2014, of references to IEC 60601-1-6:2010 and IEC 60601-1-6:2010/AMD1:2013, of references and requirements to IEC 60601-1-8:2006 and IEC 60601-1-8:2006/AMD1:2012, of references to IEC 60601-1-9:2007 and IEC 60601-1-9:2007/AMD1:2013, of references to IEC 60601-1-10:2007 and IEC 60601-1-10:2007/AMD1:2013 and of references to IEC 60601-1-11:2015;
b) widening of the scope;
c) editorial improvements;
d) addition of requirements for anticoagulant delivery means;
e) other few small technical changes.
- Standard156 pagesEnglish and French languagesale 15% off
IEC 60601-2-39:2018 is also available as IEC 60601-2-39:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60601-2-39:2018 applies to the basic safety and essential performance of peritoneal dialysis medical electrical equipment. It applies to peritoneal dialysis equipment intended for use either by medical staff or under the supervision of medical experts, including peritoneal dialysis equipment operated by the patient, regardless of whether the peritoneal dialysis equipment is used in a hospital or domestic environment. This third edition cancels and replaces the second edition of IEC 60601-2-39. It constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition:
- update of the references to IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012, of references and requirements to IEC 60601-1-2:2014, of references to IEC 60601-1-6:2010 and IEC 60601-1-6:2010/AMD1:2013, of references and requirements to IEC 60601-1-8:2006 and IEC 60601-1-8:2006/AMD1:2012 and of references and requirements to IEC 60601-1-11:2015;
- editorial improvements;
- improvement of the essential performance requirements clause/subclauses;
- new requirements for the interruption of the power supply.
- Standard57 pagesEnglish and French languagesale 15% off
IEC 62653:2012(E) which is a technical report, describes the technical requirements for use of equipment in haemodialysis, haemofiltration and haemodiafiltration. These principles should be complied with to ensure safe, permissible and proper application. The physician is responsible for the haemodialysis treatment prescription. However, the organization administering the treatment is responsible for all resources, structures and processes used in connection with the treatment. These responsibilities will not be described here. If applicable, the scope may be applicable to the use of the equipment in paediatrics, home haemodialysis, acute and sorbent dialysis systems. This technical report is not intended to be used as the basis of regulatory inspection or certification assessment activities.
- Technical report30 pagesEnglish languagesale 15% off
IEC 60601-2-16:2012 applies to the basic safety and essential performance of haemodialysis, haemodiafiltration and haemofiltration equipment. IEC 60601-2-16:2012 does not take into consideration the dialysis fluid control system of Haemodialysis equipment using regeneration of dialysis fluid and central delivery systems. It does however take into consideration the specific safety requirements of such haemodialysis equipment concerning electrical safety and patient safety. IEC 60601-2-16:2012 specifies the minimum safety requirements for haemodialysis equipment. These devices are intended for use either by medical staff or for use by the patient or other trained personnel under the supervision of medical expertise. IEC 60601-2-16:2012 includes all electromedical equipment that is intended to deliver a haemodialysis, haemodiafiltration and haemofiltration treatment to a patient suffering from kidney failure. This fourth edition cancels and replaces the third edition of IEC 60601-2-16, published in 2008. This edition constitutes a technical revision. Changes since the previous edition include, among others, better adaptation of IEC 60601-1-8 and improvement of subclause 201.8.3.
- Standard134 pagesEnglish and French languagesale 15% off