ISO/TC 106/SC 8/WG 4 - Mechanical testing
Essais mécaniques
General Information
ISO 14801:2016 specifies a method of dynamic testing of single post endosseous dental implants of the transmucosal type in combination with their premanufactured prosthetic components. It is most useful for comparing endosseous dental implants of different designs or sizes. This International Standard is not a test of the fundamental fatigue properties of the materials from which the endosseous implants and prosthetic components are made. This International Standard is not applicable to dental implants with endosseous lengths shorter than 8 mm nor to magnetic attachments. While ISO 14801:2016 simulates the functional loading of an endosseous dental implant under "worst case" conditions, it is not applicable for predicting the in vivo performance of an endosseous dental implant or dental prosthesis, particularly if multiple endosseous dental implants are used for a dental prosthesis.
- Standard16 pagesEnglish languagesale 15% off
- Standard16 pagesEnglish languagesale 15% off
- Standard20 pagesFrench languagesale 15% off
- Standard20 pagesFrench languagesale 15% off
ISO/TS 13498:2011 establishes a method to determine the torsional yield strength and maximum torque of the implant body/connecting part joints of endosseous dental implant systems. This test is most appropriate for evaluating new types of joints and connecting parts, as well as new materials. ISO/TS 13498:2011 provides a protocol for torsional loading of an implant body/connecting part joint. It is not applicable for predicting the in vivo performance of an endosseous dental implant system and it is not derived from observations of clinical failure.
- Technical specification7 pagesEnglish languagesale 15% off
- Technical specification7 pagesFrench languagesale 15% off
ISO 11953:2010 describes a classification system for hand-held torque wrenches intended for clinical use. It specifies their performance requirements in terms of accuracy and reproducibility and resistance to reprocessing. Test methods are described, and marking and labelling requirements specified.
- Standard7 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
ISO 14801:2007 specifies a method of fatigue testing of single post endosseous dental implants of the transmucosal type and their premanufactured prosthetic components. It is most useful for comparing endosseous dental implants of different designs or sizes. While it simulates the functional loading of an endosseous dental implant body and its premanufactured prosthetic components under “worst case” conditions, ISO 14801:2007 is not applicable for predicting the in vivo performance of an endosseous dental implant or prosthesis, particularly if multiple endosseous dental implants are used for a prosthesis.
- Standard9 pagesEnglish languagesale 15% off
- Standard10 pagesFrench languagesale 15% off