The document specifies test conditions for determining the seasonal performance characteristics of air source heat pump water heaters for space heating with electrically driven compressors with or without supplementary heater. The purpose of this document is to rate performance of the heat pump water heaters for space heating with no operation of any supplementary heater. In the case of heat pump water heaters for space heating consisting of several parts with refrigerant or water connections, this document applies only to those designed and supplied as a complete package. The seasonal coefficient of performance depends, inter alia, on the climate conditions and temperature regime of the space heating distribution network. This document defines: — three design conditions, each of them being characterized by a design temperature which represents the lowest temperature that can occur in that design condition; — three water temperature distribution regimes, namely "temperature application" in the text. The user of this document is free to determine the seasonal coefficient of performance for one or more of the defined design conditions and for one or more of the defined temperature applications. This document also provides a full description of three heating seasons that can be used with the associated design conditions.

  • Standard
    47 pages
    English language
    sale 15% off
  • Draft
    45 pages
    English language
    sale 15% off

This document specifies test conditions and test procedures for determining the performance characteristics of air source heat pump water heaters for space heating with electrically driven compressors with or without supplementary heater. The purpose of this document is to rate the performance of the heat pump water heaters for space heating with no operation of any supplementary heater. In the case of heat pump water heaters for space heating consisting of several parts with refrigerant or water connections, this document applies only to those designed and supplied as a complete package. NOTE Testing procedures for simultaneous operation for hot water supply and space heating are not treated in this document. Simultaneous means that hot water supply and space heating generation occur at the same time and can interact.

  • Standard
    25 pages
    English language
    sale 15% off

This document specifies test conditions and test procedures for determining the performance characteristics of air source heat pump water heaters for hot water supply with electrically driven compressors with or without supplementary electric heater and connected to or including only one hot water storage tank. Hot water storage tanks that are connected in series or parallel and behave hydronically as one single tank are considered as one hot water storage tank. In the case of heat pump water heaters consisting of several parts with refrigerant or water connections, this document applies only to those designed and supplied as a complete package. NOTE This document is not applicable to testing procedures for simultaneous operation for hot water supply and space heating. "Simultaneous" means that hot water supply and space heating generation occur at the same time and may interact.

  • Standard
    30 pages
    English language
    sale 15% off