TP100 - Pravilnik o zaščiti stavb pred vlago
Pravilnik o zaščiti stavb pred vlago
Pravilnik o zaščiti stavb pred vlago
Sklic na serijo DIN 18195!
General Information
This document specifies a method for determining the water-vapour transmission properties of
coatings of paints, varnishes and related products.
It supplements ISO 12572. As far as possible, the procedure, the definitions and the calculations
have been taken over from ISO 12572. ISO 12572 can be consulted, if necessary, to obtain a better
understanding of the procedure specified in this document.
Water-vapour transmission rates of more than 680 g/(m2⋅d) (i.e. water-vapour diffusion-equivalent air
layer thicknesses, sd, of less than 0,03 m) are not accurately quantified by the test method described in
this document.
- Standard26 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard defines the test method to be used to determine the watertightness of completely assembled windows and doorsets of any materials. This test method is designed to take account of conditions in use, when the window or doorset is installed in accordance with the manufacturer’s specification and the requirements of relevant European Standards and codes of practice.
This European Standard does not apply to the joints between the window or doorset frame and the building construction.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
This standard specifies rules for the execution of permanent protective layers for water-proofings against - ground moisture according to DIN 18195-4 - non-pressing water according to DIN 18195-5 and - outside pressing water according to DIN 18195-6 and states the protective measures which have to be taken to avoid damages of the water-proofing during the construction time.
- Standard + National Annex and/or Foreword13 pagesForeword and/or annex in Slovenian language, body of the standard in German languagesale 10% offe-Library read for1 day
This standard specifies the requirements of water-proofing of buildings. Part 5 gives details about the design and execution of water-proofings against non-pressing water.
- Standard + National Annex and/or Foreword15 pagesForeword and/or annex in Slovenian language, body of the standard in German languagesale 10% offe-Library read for1 day
This standard discribes principles of waterproofing of buildings. It contains definition and a table in which waterproofing types are assigned to the kind of water straining and the kind of soil.
- Standard + National Annex and/or Foreword15 pagesForeword and/or annex in Slovenian language, body of the standard in German languagesale 10% offe-Library read for1 day
This standard is applicable in connection with waterproofing against - ground moisture according to DIN 18195-4 - non-pressing water according to DIN 18195-5 and - outside pressing water according to DIN 18195-6 used in penetrations, transitions and seals. This standard is not applicable to waterproof coverings for roofs or decks of bridges on public highways (see also DIN 18195-1).
- Standard + National Annex and/or Foreword22 pagesForeword and/or annex in Slovenian language, body of the standard in German languagesale 10% offe-Library read for1 day
This standard specifies the requirements of waterproofings of buildings against groundmoisture. Part 4 gives details about the design and execution of waterproofings.
- Standard + National Annex and/or Foreword13 pagesForeword and/or annex in Slovenian language, body of the standard in German languagesale 10% offe-Library read for1 day
This standard specifies the requirements of water-proofing of buildings. Part 6 gives details about the design and execution of water-proofings against outside pressing water.
- Standard + National Annex and/or Foreword15 pagesForeword and/or annex in Slovenian language, body of the standard in German languagesale 10% offe-Library read for1 day
This standard specifies the requirements of the waterproofing of buildings. Part 3 contains the description of the processing of the materials.
- Standard + National Annex and/or Foreword17 pagesForeword and/or annex in Slovenian language, body of the standard in German languagesale 10% offe-Library read for1 day
This standard is applicable in connection with waterproofing against - ground moisture according to DIN 18195-4 - non-pressing water according to DIN 18195-5 and - outside pressing water according to DIN 18195-6 for waterproofing of movement joints in structures.
- Standard + National Annex and/or Foreword15 pagesForeword and/or annex in Slovenian language, body of the standard in German languagesale 10% offe-Library read for1 day
This standard specifies the requirements of materials which are to be used for waterproofings of buildings.
- Standard + National Annex and/or Foreword19 pagesForeword and/or annex in Slovenian language, body of the standard in German languagesale 10% offe-Library read for1 day
This standard deals with the waterproofing of structures by means of bitumious materials, metal strips and synthetic waterproofing sheats to prevent leakage of water pressing from the inside, i. e. water exerting hydrostatic pressure on the waterproog seal from inside, such as in drinking water tanks, reservoirs, swimming pools and stormwater retention tanks. This standard does not deal with seals for earthworks or for protection against chemicals.
- Standard + National Annex and/or Foreword12 pagesForeword and/or annex in Slovenian language, body of the standard in German languagesale 10% offe-Library read for1 day
This International Standard specifies methods for the determination of declared and design thermal values for thermally homogeneous building materials and products, together with procedures to convert values obtained under one set of conditions to those valid for another set of conditions. These procedures are valid for design ambient temperatures between 30 °C and 60 °C. This International Standard provides conversion coefficients for temperature and for moisture. These coefficients are valid for mean temperatures between 0 °C and 30 °C. This International Standard also provides design data in tabular form for use in heat and moisture transfer calculations, for thermally homogeneous materials and products commonly used in building construction.
- Standard33 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard specifies a method for determining the liquid water permeability of coatings, coating systems and related products, intended for exterior masonry and classification according to EN 1062-1.
The method is applicable to coatings and coating systems on porous substrates such as brick, concrete and renderings.
A liquid water permeability w of more than 0,5 kg/(m² x h0,5) will not be accurately quantified by the test method described in this standard.
- Standard8 pagesEnglish languagesale 10% offe-Library read for1 day
This European Standard applies to wastewater drainage systems, which operate under gravity. It is applicable for drainage systems inside dwellings and commercial, institutional and industrial buildings. This third part of this European Standard describes a method of calculating the hydraulic adequacy of non-siphonic roof drainage systems and gives performance requirements for siphonic roof drainage systems. It also sets standards for the layout and installation of roof drainage insofar as they affect flow capacity.
- Standard47 pagesEnglish languagesale 10% offe-Library read for1 day
This standards defines the classification of test results for completely assembled windows and doors of any after testing in accordance with prEN 1027 "Windows and doors - Watertightness - Test method".
- Standard4 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard4 pagesEnglish languagesale 10% offe-Library read for1 day